Vanillylmandelic and Homovanillic acid: Electroanalysis at non-modified and polymer-modified carbon-based electrodes

被引:38
|
作者
Baluchova, Simona [1 ]
Barek, Jiri [1 ]
Tome, Luciana I. N. [2 ]
Brett, Christopher M. A. [2 ]
Schwarzova-Peckova, Karolina [1 ]
机构
[1] Charles Univ Prague, Dept Analyt Chem, Fac Sci, UNESCO Lab Environm Electrochem, Albertov 6, Prague 12843 2, Czech Republic
[2] Univ Coimbra, Fac Sci & Technol, Dept Chem, Rua Larga, P-3004535 Coimbra, Portugal
关键词
Homovanillic acid; Vanillylmandelic acid; Boron-doped diamond; Modified glassy carbon electrode; Voltammetry; BORON-DOPED DIAMOND; HUMAN URINE SAMPLES; PERFORMANCE LIQUID-CHROMATOGRAPHY; COMPETITIVE ENZYME-IMMUNOASSAY; NEUROENDOCRINE TUMOR-MARKERS; CAPILLARY-ELECTROPHORESIS; CATECHOLAMINE METABOLITES; AMPEROMETRIC DETECTION; MASS-SPECTROMETRY; ASCORBIC-ACID;
D O I
10.1016/j.jelechem.2018.03.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical behaviour of two main catecholamine metabolites serving as diagnostic tumour biomarkers, homovanillic acid (HVA) and vanillylmandelic acid (VMA), on anodically oxidized boron doped diamond (BDD) electrodes, non-modified glassy carbon electrodes (GCE), and GCE modified by polymers, namely by Nafion (Nafion/GCE) and by poly(neutral red) (PNR/GCE), was investigated. The voltammetric responses of both biomarkers are strongly dependent on pH of the aqueous buffer solution and electrode material used. BDD electrodes exhibit more positive oxidation potentials and lower current densities for oxidation of both analytes, depending also on the surface termination. Concentration dependences were measured in 0.1 mol L-1 phosphate buffer pH 3.0, as optimal supporting electrolyte for differential pulse voltammetric determination. Achieved detection limits were 0.6, 0.9, 0.8, and 1.2 mu mol L-1 for HVA and 0.4, 1.5, 2.4, and 1.1 mu mol L-1 for VMA at BDD electrodes, non-modified GCE, Nafion/GCE, and PNR/GCE, respectively. The limits of quantification for both organic compounds on all tested electrode materials are sufficiently low for their determination in urine. Verification of the possibility of simultaneous voltammetric determination of the studied biomarkers in the mixture was also carried out.
引用
收藏
页码:22 / 32
页数:11
相关论文
共 50 条
  • [21] Biodegradable polymer-modified graphene/polyaniline electrodes for supercapacitors
    Htut, K. Zin
    Kim, Minjae
    Lee, Eunsoo
    Lee, Gibaek
    Baeck, Sung Hyeon
    Shim, Sang Eun
    SYNTHETIC METALS, 2017, 227 : 61 - 70
  • [22] POLYMER-MODIFIED ELECTRODES - A NEW CLASS OF ELECTROCHROMIC MATERIALS
    KAUFMAN, FB
    SCHROEDER, AH
    ENGLER, EM
    PATEL, VV
    APPLIED PHYSICS LETTERS, 1980, 36 (06) : 422 - 425
  • [23] Electrochemical and structural characteristics of activated carbon-based electrodes modified via phosphoric acid
    Yu, Hye-Ryeon
    Cho, Seho
    Jung, Min-Jung
    Lee, Young-Seak
    MICROPOROUS AND MESOPOROUS MATERIALS, 2013, 172 : 131 - 135
  • [24] An overview of the electrochemical reduction of oxygen at carbon-based modified electrodes
    B. Šljukić
    C. E. Banks
    R. G. Compton
    Journal of the Iranian Chemical Society, 2005, 2 : 1 - 25
  • [25] Polymer-Modified Carbon: Electrochemical Behavior of Temazepam
    Inam-Ul-Haque
    Bano, Kiran
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2012, 34 (05): : 1144 - 1150
  • [26] An overview of the electrochemical reduction of oxygen at carbon-based modified electrodes
    Sljukic, B.
    Banks, C. E.
    Compton, R. G.
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2005, 2 (01) : 1 - 25
  • [27] Voltammetric Detection of Vanillylmandelic Acid and Homovanillic Acid Using Urea-Derivative-Modified Graphite Electrode
    Shishkanova, Tatiana V.
    Kralik, Frantisek
    Synytsya, Alla
    SENSORS, 2023, 23 (07)
  • [28] ELECTROANALYSIS OF AROMATIC-ALDEHYDES WITH MODIFIED CARBON PASTE ELECTRODES
    LIU, KE
    ABRUNA, HD
    ANALYTICAL CHEMISTRY, 1989, 61 (23) : 2599 - 2602
  • [29] Electrochemical sensors of heavy metals using novel polymer-modified glassy carbon electrodes
    Vedhi, C.
    Selvanathan, G.
    Arumugam, P.
    Manisankar, P.
    IONICS, 2009, 15 (03) : 377 - 383
  • [30] Electroanalysis of NADH using conducting and redox active polymer/carbon nanotubes modified electrodes - A review
    Kumar, S. Ashok
    Chen, Shen-Ming
    SENSORS, 2008, 8 (02) : 739 - 766