Vanillylmandelic and Homovanillic acid: Electroanalysis at non-modified and polymer-modified carbon-based electrodes

被引:38
|
作者
Baluchova, Simona [1 ]
Barek, Jiri [1 ]
Tome, Luciana I. N. [2 ]
Brett, Christopher M. A. [2 ]
Schwarzova-Peckova, Karolina [1 ]
机构
[1] Charles Univ Prague, Dept Analyt Chem, Fac Sci, UNESCO Lab Environm Electrochem, Albertov 6, Prague 12843 2, Czech Republic
[2] Univ Coimbra, Fac Sci & Technol, Dept Chem, Rua Larga, P-3004535 Coimbra, Portugal
关键词
Homovanillic acid; Vanillylmandelic acid; Boron-doped diamond; Modified glassy carbon electrode; Voltammetry; BORON-DOPED DIAMOND; HUMAN URINE SAMPLES; PERFORMANCE LIQUID-CHROMATOGRAPHY; COMPETITIVE ENZYME-IMMUNOASSAY; NEUROENDOCRINE TUMOR-MARKERS; CAPILLARY-ELECTROPHORESIS; CATECHOLAMINE METABOLITES; AMPEROMETRIC DETECTION; MASS-SPECTROMETRY; ASCORBIC-ACID;
D O I
10.1016/j.jelechem.2018.03.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical behaviour of two main catecholamine metabolites serving as diagnostic tumour biomarkers, homovanillic acid (HVA) and vanillylmandelic acid (VMA), on anodically oxidized boron doped diamond (BDD) electrodes, non-modified glassy carbon electrodes (GCE), and GCE modified by polymers, namely by Nafion (Nafion/GCE) and by poly(neutral red) (PNR/GCE), was investigated. The voltammetric responses of both biomarkers are strongly dependent on pH of the aqueous buffer solution and electrode material used. BDD electrodes exhibit more positive oxidation potentials and lower current densities for oxidation of both analytes, depending also on the surface termination. Concentration dependences were measured in 0.1 mol L-1 phosphate buffer pH 3.0, as optimal supporting electrolyte for differential pulse voltammetric determination. Achieved detection limits were 0.6, 0.9, 0.8, and 1.2 mu mol L-1 for HVA and 0.4, 1.5, 2.4, and 1.1 mu mol L-1 for VMA at BDD electrodes, non-modified GCE, Nafion/GCE, and PNR/GCE, respectively. The limits of quantification for both organic compounds on all tested electrode materials are sufficiently low for their determination in urine. Verification of the possibility of simultaneous voltammetric determination of the studied biomarkers in the mixture was also carried out.
引用
收藏
页码:22 / 32
页数:11
相关论文
共 50 条
  • [31] Carbon-based composite electrodes: Preparation, characterization and application in electroanalysis
    Corb, Ioana
    Manea, Florica
    Radovan, Ciprian
    Pop, Aniela
    Burtica, Georgeta
    Malchev, Plamen
    Picken, Stephen
    Schoonman, Joop
    SENSORS, 2007, 7 (11) : 2626 - 2635
  • [32] Carbon containing electrodes modified with the iodate salts of aryldiazonium for electroanalysis
    Gusar, Anna
    Gashevskya, Anna
    Dorozhko, Elena
    Derina, Ksenia
    PROCEEDINGS OF THE 14TH INTERNATIONAL STUDENTS CONFERENCE MODERN ANALYTICAL CHEMISTRY, 2018, : 134 - 139
  • [33] ELECTROANALYSIS OF PRIMARY AMINES WITH CHEMICALLY MODIFIED CARBON PASTE ELECTRODES
    GUADALUPE, AR
    JHAVERI, SS
    LIU, KE
    ABRUNA, HD
    ANALYTICAL CHEMISTRY, 1987, 59 (19) : 2436 - 2438
  • [34] Electrochemical sensors of heavy metals using novel polymer-modified glassy carbon electrodes
    C. Vedhi
    G. Selvanathan
    P. Arumugam
    P. Manisankar
    Ionics, 2009, 15
  • [35] Voltammetric sensor array based on conducting polymer-modified electrodes for the discrimination of liquids
    Arrieta, AA
    Apetrei, C
    Rodríguez-Méndez, ML
    de Saja, JA
    ELECTROCHIMICA ACTA, 2004, 49 (26) : 4543 - 4551
  • [36] Resolution of dopamine and ascorbic acid using nickel(II) complex polymer-modified electrodes
    Yi, Seon-Young
    Chang, Hye-Young
    Cho, Hyung-hwa
    Park, Yu Chul
    Lee, Sang Hak
    Bae, Zun-Ung
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2007, 602 (02): : 217 - 225
  • [37] Removal of Zinc from Wafer Using Modified and Non-Modified Carbon Nanofibers
    Atieh, Muataz Ali
    ENVIRONMENTAL SCIENCE AND TECHNOLOGY, PT 1, 2011, 6 : VI220 - VI223
  • [38] Elastomeric conductive composites based on conducting polymer-modified carbon black
    Zucolotto, V
    Avlyanov, J
    Mattoso, LHC
    POLYMER COMPOSITES, 2004, 25 (06) : 617 - 621
  • [39] POLYMER-MODIFIED ELECTRODES IN LIQUID CHROMATOGRAPHY-ELECTROCHEMICAL DETECTION
    GUNASINGHAM, H
    TAN, CB
    TAN, CH
    AW, TC
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1989, 27 (11) : 672 - 675
  • [40] FOULING-RESISTANT, POLYMER-MODIFIED GRAPHITE-ELECTRODES
    WHEELER, SK
    COURY, LA
    HEINEMAN, WR
    ANALYTICA CHIMICA ACTA, 1990, 237 (01) : 141 - 148