Experimental study of double-panel confined masonry walls under lateral loading

被引:12
|
作者
Belghiat, Choayb [1 ,3 ]
Messabhia, Ali [1 ]
Plassiard, Jean-Patrick [3 ]
Guenfoud, Mohamed [1 ,2 ]
Ple, Olivier [3 ]
Perrotin, Pascal [3 ]
机构
[1] Univ Larbi Tebessi, Appl Civil Engn Lab, Route Constantine, Tebessa 12002, Algeria
[2] Univ 8 May 1945 Guelma, BP 401, Guelma 24000, Algeria
[3] Univ Savoie Mt Blanc, CNRS, LOCIE, Campus Sci Savoie Technolac, F-73376 Le Bourget Du Lac, Chambery, France
关键词
Confined masonry; Uniform confinement; Toothed confinement; Wall density; Double-panel; Pushover test;
D O I
10.1016/j.jobe.2018.09.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Confined masonry structures are one of the most widely used construction systems in Algeria, in which both walls and confining elements contribute to carrying the gravity and seismic loads. Several types of confining elements are used (uniform confinements, toothed confinements), each one giving the structure a different mechanical behavior while the wall density is considered as a key safety factor for those structures. The study presented in this paper is an experimental study on two types of confinement. The study originality stems from the size of the tested samples, which included double-panel confined masonry and experimental pushover tests. First, uniform masonry walls and confinements are studied. Second, toothed masonry walls consisting of two panels of Algerian clay bricks are tested. The objectives were on one hand to study the impact of the frame/panel connection on the quasi-static behavior of the structure as well as the loading and unloading behaviors. On the other hand, to highlight the impact of using double-panel walls on resisting mechanism of confined masonry walls. Moreover, the obtained data were used for evaluating the existing analytical models to predict lateral capacities of confined masonry walls. The results indicate that the two sample-types show some similar resisting mechanisms but various capacities under progressive lateral loading, which may have consequences on the seismic resistance of the structure. A mixture of shear-flexural mechanism can be noticed when double-panel walls are used.
引用
收藏
页码:531 / 543
页数:13
相关论文
共 50 条
  • [31] Theoretical Verification of Existing Solutions on Lateral Loading of Masonry Infill Walls
    Bakeer, Tammam
    MAUERWERK, 2011, 15 (01) : 35 - 42
  • [32] Behavior of Partially Grouted Concrete Masonry Walls under Quasi-Static Cyclic Lateral Loading
    Calderon, Sebastian
    Vargas, Laura
    Sandoval, Cristian
    Araya-Letelier, Gerardo
    MATERIALS, 2020, 13 (10)
  • [33] Structural performance of confined masonry walls retrofitted using ferrocement and GFRP under in-plane cyclic loading
    El-Diasity, Mosaad
    Okail, Hussein
    Kamal, Osama
    Said, Mohamed
    ENGINEERING STRUCTURES, 2015, 94 : 54 - 69
  • [34] Flexural Behavior of Confined Masonry Walls Subjected to In-Plane Lateral Loads
    Varela-Rivera, Jorge
    Fernandez-Baqueiro, Luis
    Gamboa-Villegas, Jose
    Prieto-Coyoc, Adda
    Moreno-Herrera, Joel
    EARTHQUAKE SPECTRA, 2019, 35 (01) : 405 - 422
  • [35] Experimental study on performance of stone masonry walls under axial compression
    Xu X.
    Guo Z.
    Chai Z.
    Ye Y.
    Wang L.
    Hou W.
    Guo, Zixiong (guozxcy@hqu.edu.cn), 1600, Science Press (38): : 148 - 153
  • [36] Experimental study on the seismic behavior of masonry walls under offshore environment
    Niu, LiHua
    Zheng, ShanSuo
    Li, Lei
    STRUCTURES, 2020, 28 : 433 - 445
  • [37] Experimental study on seismic performance of reinforced concrete shear walls with flange under biaxial lateral loading
    Wang B.
    Wu M.-Z.
    Shi Q.-X.
    Cai W.-Z.
    Gong H.-X.
    Zhendong Gongcheng Xuebao/Journal of Vibration Engineering, 2024, 37 (04): : 588 - 600
  • [38] EXPERIMENTAL INVESTIGATION OF GROUTED ANCHORS IN NATURAL STONE MASONRY WALLS UNDER STATIC AND CYCLIC LOADING
    Hamdan, A.
    Jaeger, W.
    PROCEEDINGS OF THE 9TH AUSTRALASIAN MASONRY CONFERENCE, 2011, : 41 - 50
  • [39] Experimental analysis of historic masonry walls reinforced by CFRP under in-plane cyclic loading
    Capozucca, Roberto
    COMPOSITE STRUCTURES, 2011, 94 (01) : 277 - 289
  • [40] Experimental and analytical assessment on rubberized concrete interlocking grouted masonry walls under eccentric loading
    Al-Fakih, Amin
    STRUCTURES, 2022, 44 : 893 - 903