Experimental study of double-panel confined masonry walls under lateral loading

被引:12
|
作者
Belghiat, Choayb [1 ,3 ]
Messabhia, Ali [1 ]
Plassiard, Jean-Patrick [3 ]
Guenfoud, Mohamed [1 ,2 ]
Ple, Olivier [3 ]
Perrotin, Pascal [3 ]
机构
[1] Univ Larbi Tebessi, Appl Civil Engn Lab, Route Constantine, Tebessa 12002, Algeria
[2] Univ 8 May 1945 Guelma, BP 401, Guelma 24000, Algeria
[3] Univ Savoie Mt Blanc, CNRS, LOCIE, Campus Sci Savoie Technolac, F-73376 Le Bourget Du Lac, Chambery, France
关键词
Confined masonry; Uniform confinement; Toothed confinement; Wall density; Double-panel; Pushover test;
D O I
10.1016/j.jobe.2018.09.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Confined masonry structures are one of the most widely used construction systems in Algeria, in which both walls and confining elements contribute to carrying the gravity and seismic loads. Several types of confining elements are used (uniform confinements, toothed confinements), each one giving the structure a different mechanical behavior while the wall density is considered as a key safety factor for those structures. The study presented in this paper is an experimental study on two types of confinement. The study originality stems from the size of the tested samples, which included double-panel confined masonry and experimental pushover tests. First, uniform masonry walls and confinements are studied. Second, toothed masonry walls consisting of two panels of Algerian clay bricks are tested. The objectives were on one hand to study the impact of the frame/panel connection on the quasi-static behavior of the structure as well as the loading and unloading behaviors. On the other hand, to highlight the impact of using double-panel walls on resisting mechanism of confined masonry walls. Moreover, the obtained data were used for evaluating the existing analytical models to predict lateral capacities of confined masonry walls. The results indicate that the two sample-types show some similar resisting mechanisms but various capacities under progressive lateral loading, which may have consequences on the seismic resistance of the structure. A mixture of shear-flexural mechanism can be noticed when double-panel walls are used.
引用
收藏
页码:531 / 543
页数:13
相关论文
共 50 条
  • [41] Experimental research on the seismic behavior of confined shale brick masonry walls
    Wang, Zhenggang
    Xue, Guoya
    Gao, Benli
    Zhang, Jintao
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2003, 33 (05): : 638 - 642
  • [42] Experimental study of in-plane shear strength of confined concrete masonry walls with joint reinforcement
    Cruz O, A. I.
    Perez-Gavilan E, J. J.
    Flores C, L.
    ENGINEERING STRUCTURES, 2019, 182 : 213 - 226
  • [43] Behavior of slender, posttensioned masonry walls under transverse loading
    Popehn, Jennifer R. Bean
    Schultz, Arturo E.
    Drake, Christopher R.
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2007, 133 (11): : 1541 - 1550
  • [44] EXPERIMENTAL STUDY OF CORRUGATED TUBES UNDER LATERAL LOADING
    Eyvazian, A.
    Shakeri, M.
    Mahmoudabadi, M. Zarei
    PROCEEDINGS OF THE ASME 10TH BIENNIAL CONFERENCE ON ENGINEERING SYSTEMS DESIGN AND ANALYSIS, 2010, VOL 2, 2010, : 233 - 241
  • [45] Experimental study of corrugated tubes under lateral loading
    Eyvazian, A.
    Akbarzadeh, I.
    Shakeri, M.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART L-JOURNAL OF MATERIALS-DESIGN AND APPLICATIONS, 2012, 226 (L2) : 109 - 118
  • [46] SEISMIC BEHAVIOR OF CONFINED MASONRY WALLS UNDER ACIDIC ATMOSPHERIC ENVIRONMENT
    Zheng, ShanSuo
    Niu, Lihua
    Zheng, Hao
    Zhang, QiuShi
    Zhu, Lanqi
    INGEGNERIA SISMICA, 2017, 34 (02): : 98 - 125
  • [47] Double-leaf masonry walls under in-plane loading strengthened with GFRP/SRG strips
    Capozucca, R.
    ENGINEERING STRUCTURES, 2016, 128 : 453 - 473
  • [48] Behavior of concrete masonry infills bounded by masonry frames subjected to in-plane lateral loading - Experimental study
    Roosta, Soraya
    Liu, Yi
    ENGINEERING STRUCTURES, 2021, 247
  • [49] Experimental Study of Confined Brick Masonry Building
    Shukla, A. K.
    Maiti, P. R.
    ADVANCES IN STRUCTURAL ENGINEERING AND REHABILITATION, 2020, 38 : 15 - 40
  • [50] Composite action in masonry walls under vertical in-plane loading: experimental results compared with predictions
    Vermeltfoort, A. T.
    Martens, D. R. W.
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2015, 42 (07) : 449 - 462