Structural performance of confined masonry walls retrofitted using ferrocement and GFRP under in-plane cyclic loading

被引:61
|
作者
El-Diasity, Mosaad [1 ]
Okail, Hussein [2 ]
Kamal, Osama [1 ]
Said, Mohamed [1 ]
机构
[1] Benha Univ, Shoubra Fac Engn, Dept Struct Engn, Banha, Egypt
[2] Ain Shams Univ, Dept Struct Engn, Ain Shams, Egypt
关键词
Confined masonry; Seismic behavior; Cyclic loading; Shear failure; Ferrocement; Expanded mesh; Glass woven fibers;
D O I
10.1016/j.engstruct.2015.03.035
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the results of in-plane cyclic loading tests conducted on confined masonry walls retrofitted using low-cost ferrocement and GFRP systems. Ten wall assemblies with a 0.80-scale were built, consisting of a clay masonry panel, two confining columns and a tie beam. The assemblies were tested under a combination of a vertical load and lateral reversed cyclic loading with a displacement controlled loading protocol up to failure. Wall panels had various configurations, namely, solid walls, perforated walls with window and door openings. Two composite materials (ferrocement and GFRP) and three retrofitting configurations (diagonal "X", corner, and full coverage) were investigated. Key experimental results showed that the proposed upgrading techniques improved the lateral resistance of the confined walls by a factor ranging from 25% to 32%with a significant increase in the ductility and energy absorption of the panel ranging from 33% to 85%; however, the improvement in lateral drifts was less significant. Regarding the upgrading configurations, the diagonal "X" and full coverage can help prevent diagonal shear failure especially in tie columns and convert the failure mode to a panel-rocking mode. Additionally, in all retrofitting cases, collapse was significantly delayed by maintaining the wall integrity under large lateral deformations. A good agreement was found by comparing deformed shapes, crack patterns and capacity curves of finite element models included in this study. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:54 / 69
页数:16
相关论文
共 50 条
  • [1] In-plane cyclic response of unreinforced masonry walls retrofitted with ferrocement
    Hasnat, Abul
    Das, Tanmoy
    Ahsan, Raquib
    Alam, Ahmed Tohameem
    Ahmed, Hafiz
    [J]. CASE STUDIES IN CONSTRUCTION MATERIALS, 2022, 17
  • [2] Seismic In-plane performance of retrofitted masonry walls
    Farooq, S. H.
    Mohamed, A. ElGawady
    Ilyas, M.
    [J]. KSCE JOURNAL OF CIVIL ENGINEERING, 2014, 18 (01) : 226 - 237
  • [3] Seismic In-plane performance of retrofitted masonry walls
    S. H. Farooq
    A. ElGawady Mohamed
    M. Ilyas
    [J]. KSCE Journal of Civil Engineering, 2014, 18 : 226 - 237
  • [4] Cyclic in-plane behavior of unreinforced and confined masonry walls retrofitted by shotcrete: Experimental investigation
    Rezaee, Seyed Rahman Seyed
    Soltani, Masoud
    Nikooravesh, Morteza
    [J]. ENGINEERING STRUCTURES, 2022, 264
  • [5] In-Plane Experimental Behavior of Stone Masonry Walls under Cyclic Loading
    Vasconcelos, G.
    Lourenco, P. B.
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2009, 135 (10) : 1269 - 1277
  • [6] Seismic capacity of brick masonry walls externally bonded GFRP under in-plane loading
    Wang, Quanfeng
    Chai, Zhenling
    Wang, Lingyun
    [J]. STRUCTURAL ENGINEERING AND MECHANICS, 2014, 51 (03) : 413 - 431
  • [7] Assessment of masonry arch bridges retrofitted by sprayed concrete under in-plane cyclic loading
    Yazdani, Mahdi
    Zirakbash, Mehrdad
    [J]. STRUCTURAL MONITORING AND MAINTENANCE, AN INTERNATIONAL JOURNAL, 2024, 11 (01): : 57 - 70
  • [8] Seismic behavior of unreinforced and confined masonry walls using innovative sintered insulation shale blocks under cyclic in-plane loading
    Qin, Chaogang
    Bai, Guoliang
    Wu, Tao
    Wang, Bo
    Fu, Guangming
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2021, 268
  • [9] Damage evolution and failure mechanism of masonry walls under in-plane cyclic loading
    Pan, Jia-Liu
    Shen, Jia-Xu
    Zhong, Zi-Lan
    Xia, Yu
    Li, Xiao-Dong
    Zhang, Yong-Qun
    [J]. ENGINEERING FAILURE ANALYSIS, 2024, 161
  • [10] Experimental response of masonry walls in-plane loading strengthened with GFRP strips
    Capozucca, R.
    Magagnini, E.
    [J]. COMPOSITE STRUCTURES, 2020, 235