The influence of patient centering on CT dose and image noise

被引:160
|
作者
Toth, Thomas
Ge, Zhanyu
Daly, Michael P.
机构
[1] GE Co, CT Syst Engn W 1140, GE Healthcare, Milwaukee, WI 53201 USA
[2] Univ Illinois, Dept Elect & Comp Engn, Electromagnet Lab, Urbana, IL 61801 USA
关键词
D O I
10.1118/1.2748113
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Although x-ray intensity shaping filters (bowtie filters) have been used since the introduction of some of the earliest CT scanner models, the clinical implications on dose and noise are not well understood. To achieve the intended dose and noise advantage requires the patient to be centered in the scan field of view. In this study we explore the implications of patient centering in clinical practice. We scanned various size and shape phantoms on a GE LightSpeed VCT scanner using each available source filter with the phantom centers positioned at 0, 3, and 6 cm below the center of rotation (isocenter). Surface doses were measured along with image noise over a large image region. Regression models of surface dose and noise were generated as a function of phantom size and centering error. Methods were also developed to determine the amount of miscentering using a scout scan projection radiograph (SPR). These models were then used to retrospectively evaluate 273 adult body patients for clinical implications. When miscentered by 3 and 6 cm, the surface dose on a 32 cm CTDI phantom increased by 18% and 41% while image noise also increased by 6% and 22%. The retrospective analysis of adult body scout SPR scans shows that 46% of patients were miscentered in elevation by 20-60 mm with a mean position 23 mm below the center of rotation (isocenter). The analysis indicated a surface dose penalty of up to 140% with a mean dose penalty of 33% assuming that tube current is increased to compensate for the increased noise due to miscentering. Clinical image quality and dose efficiency can be improved on scanners with bowtie filters if care is exercised when positioning patients. Automatically providing patient specific centering and scan parameter selection information can help the technologist improve workflow, achieve more consistent image quality and reduce patient dose. (C) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:3093 / 3101
页数:9
相关论文
共 50 条
  • [41] Effects on Image Quality From Increasing Noise in Low-Dose CT Perfusion
    Shih, J.
    Liu, Y.
    Herrmann, C.
    Hoelscher, A.
    Raj, A.
    Juluru, K.
    Comunale, J.
    Sanelli, P.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [42] Low-dose CT image restoration based on noise prior regression network
    Yan Jin
    Zhiwei Jiang
    Mengjia Huang
    Zhizhong Xue
    The Visual Computer, 2023, 39 : 459 - 471
  • [43] Low-dose CT image restoration based on noise prior regression network
    Jin, Yan
    Jiang, Zhiwei
    Huang, Mengjia
    Xue, Zhizhong
    VISUAL COMPUTER, 2023, 39 (01): : 459 - 471
  • [44] The influence of patient positioning on radiation dose in CT imaging: A narrative review
    Al-Hayek, Yazan
    Zheng, Xiaoming
    Hayre, Christopher
    Spuur, Kelly
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2022, 53 (04) : 737 - 747
  • [45] Influence of Pitch on Surface Dose Distribution and Image Noise of Computed Tomography Scans
    Yamada, Kenji
    Kawata, Yoshiki
    Amano, Masafumi
    Suzuki, Hidenobu
    Tominaga, Masahide
    Sasaki, Motoharu
    Nishiyama, Hikaru
    Harada, Masafumi
    Niki, Noboru
    SENSORS, 2023, 23 (07)
  • [46] Evaluation of the additional patient dose from cone beam CT image guidance
    Spiessens, S.
    Bogaerts, R.
    Depuydt, T.
    Van den Heuver, F.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S168 - S168
  • [47] Dose and image quality in CT
    Huda, W
    PEDIATRIC RADIOLOGY, 2002, 32 (10) : 709 - 713
  • [48] Dose and image quality in CT
    Walter Huda
    Pediatric Radiology, 2002, 32 : 709 - 713
  • [49] Effect of Localizer Type and Patient Off-Centering On CT Radiation Dose with Use of Automatic Tube Current Modulation
    Ruan, C.
    Sodickson, A.
    Hamberg, L.
    MEDICAL PHYSICS, 2016, 43 (06) : 3656 - 3656
  • [50] POINT ORGAN RADIATION DOSE IN ABDOMINAL CT: EFFECT OF PATIENT OFF-CENTERING IN AN EXPERIMENTAL HUMAN CADAVER STUDY
    Khawaja, Ranish Deedar Ali
    Singh, Sarabjeet
    Padole, Atul
    Otrakji, Alexi
    Lira, Diego
    Zhang, Da
    Liu, Bob
    Primak, Andrew
    Xu, George
    Kalra, Mannudeep K.
    RADIATION PROTECTION DOSIMETRY, 2017, 175 (04) : 440 - 449