Comparison of coal mine dust size distributions and calibration standards for crystalline silica analysis

被引:16
|
作者
Page, SJ [1 ]
机构
[1] NIOSH, Pittsburgh Res Ctr, Pittsburgh, PA 15236 USA
来源
AIHA JOURNAL | 2003年 / 64卷 / 01期
关键词
P7; silica; size distributions; XRD;
D O I
10.1080/15428110308984781
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Since 1982 standard calibration materials recommended for respirable crystalline silica analysis by the Mine Safety and Health Administration (MSHA) P7 Infrared Method and the National Institute for Occupational Safety and Health (NIOSH) X-ray Diffraction (XRD) Analytical Method 7500 have undergone minor changes in size distribution. However, a critical assumption has been made that the crystalline silica in ambient mine atmosphere respirable dust samples has also remained essentially unchanged in particle size distribution. Therefore, this work compared recent particle size distributions of underground coal mine dust and the silica component of these dusts with estimated aerodynamic particle size distributions of calibration standard materials MIN-U-SIL 5, Berkeley 5, and SRM 1878 used by two crystalline silica analysis techniques. Dust impactor sampling data for various locations in 13 underground coal mines were analyzed for the respirable mass median aerodynamic diameters. The data suggest that the MSHA P7 method will underestimate the silica content of the sample by at most 7.4% in the median size range 0.9 to 3.6 mum, and that it is unlikely one would obtain any significant error in the MSHA P7 method analysis when the method uses Berkeley 5, MIN-U-SIL 5, or SRM 1878 as a calibration standard material. The results suggest that the NIOSH Analytical Method 7500 would be more appropriate for a dust sample that is representative of the total (no cyclone classifier) rather than the respirable airborne dust, particularly because the mass fraction in the size range below 4 mum is usually a small percentage of the total airborne dust mass. However, NIOSH Analytical Method 7500 is likely to underestimate the silica content of an airborne respirable dust sample by only 5 to 10%. The results of this study also suggest that any changes that may have occurred in the median respirable size of airborne coal mine dust are not significant enough to cause any appreciable error in the current methods used for respirable crystalline silica analysis.
引用
收藏
页码:30 / 39
页数:10
相关论文
共 50 条
  • [21] SHAPE FACTORS OF NARROW SIZE RANGE SAMPLES OF RESPIRABLE COAL MINE DUST
    STEIN, F
    CORN, M
    POWDER TECHNOLOGY, 1976, 13 (01) : 133 - 141
  • [22] A Novel Coal Mine Dust Measurement System and Experimental Analysis
    Ren Bencheng Yu
    Tang Zihui
    Automatic Control and Computer Sciences, 2023, 57 : 348 - 354
  • [23] A Novel Coal Mine Dust Measurement System and Experimental Analysis
    Yu, Bencheng
    Ren, Zihui
    Tang, Shoufeng
    AUTOMATIC CONTROL AND COMPUTER SCIENCES, 2023, 57 (04) : 348 - 354
  • [24] Aerosol concentration and particle size distributions in underground excavations of a hard coal mine
    Skubacz, Krystian
    Wojtecki, Lukasz
    Urban, Pawel
    INTERNATIONAL JOURNAL OF OCCUPATIONAL SAFETY AND ERGONOMICS, 2017, 23 (03) : 318 - 327
  • [25] Intermethod comparison of the particle size distributions of colloidal silica nanoparticles
    Tuoriniemi, Jani
    Johnsson, Ann-Cathrin J. H.
    Holmberg, Jenny Perez
    Gustafsson, Stefan
    Gallego-Urrea, Julian A.
    Olsson, Eva
    Pettersson, Jan B. C.
    Hassellov, Martin
    SCIENCE AND TECHNOLOGY OF ADVANCED MATERIALS, 2014, 15 (03)
  • [26] Investigating the shape and size distribution of dust in mechanized longwall method in Tabas coal mine
    Arasteh, Hossein
    Saeedi, Gholamreza
    HUMAN AND ECOLOGICAL RISK ASSESSMENT, 2017, 23 (01): : 28 - 39
  • [27] BUREAU OF MINES PROCEDURE FOR IMPLEMENTING ANALYSIS OF RESPIRABLE COAL MINE DUST
    GOLDBERG, SA
    TAYLOR, CD
    RAYMOND, LD
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1972, 33 (02): : 72 - &
  • [28] Thermogravimetric analysis of respirable coal mine dust for simple source apportionment
    Jaramillo, Lizeth
    Agioutanti, Eleftheria
    Afrouz, Setareh Ghaychi
    Keles, Cigdem
    Sarver, Emily
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2022, 19 (09) : 568 - 579
  • [29] Erratum to: A Novel Coal Mine Dust Measurement System and Experimental Analysis
    Bencheng Yu
    Ren Zihui
    Tang Shoufeng
    Automatic Control and Computer Sciences, 2023, 57 (5) : 542 - 542
  • [30] Particle size distribution and particle size-related crystalline silica content in granite quarry dust
    Sirianni, Greg
    Hosgood, Howard Dean, III
    Slade, Martin D.
    Borak, Jonathan
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2008, 5 (05) : 279 - 285