Comparison of coal mine dust size distributions and calibration standards for crystalline silica analysis

被引:16
|
作者
Page, SJ [1 ]
机构
[1] NIOSH, Pittsburgh Res Ctr, Pittsburgh, PA 15236 USA
来源
AIHA JOURNAL | 2003年 / 64卷 / 01期
关键词
P7; silica; size distributions; XRD;
D O I
10.1080/15428110308984781
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Since 1982 standard calibration materials recommended for respirable crystalline silica analysis by the Mine Safety and Health Administration (MSHA) P7 Infrared Method and the National Institute for Occupational Safety and Health (NIOSH) X-ray Diffraction (XRD) Analytical Method 7500 have undergone minor changes in size distribution. However, a critical assumption has been made that the crystalline silica in ambient mine atmosphere respirable dust samples has also remained essentially unchanged in particle size distribution. Therefore, this work compared recent particle size distributions of underground coal mine dust and the silica component of these dusts with estimated aerodynamic particle size distributions of calibration standard materials MIN-U-SIL 5, Berkeley 5, and SRM 1878 used by two crystalline silica analysis techniques. Dust impactor sampling data for various locations in 13 underground coal mines were analyzed for the respirable mass median aerodynamic diameters. The data suggest that the MSHA P7 method will underestimate the silica content of the sample by at most 7.4% in the median size range 0.9 to 3.6 mum, and that it is unlikely one would obtain any significant error in the MSHA P7 method analysis when the method uses Berkeley 5, MIN-U-SIL 5, or SRM 1878 as a calibration standard material. The results suggest that the NIOSH Analytical Method 7500 would be more appropriate for a dust sample that is representative of the total (no cyclone classifier) rather than the respirable airborne dust, particularly because the mass fraction in the size range below 4 mum is usually a small percentage of the total airborne dust mass. However, NIOSH Analytical Method 7500 is likely to underestimate the silica content of an airborne respirable dust sample by only 5 to 10%. The results of this study also suggest that any changes that may have occurred in the median respirable size of airborne coal mine dust are not significant enough to cause any appreciable error in the current methods used for respirable crystalline silica analysis.
引用
收藏
页码:30 / 39
页数:10
相关论文
共 50 条
  • [41] VARIABILITY OF PARTICLE SIZE-SPECIFIC FRACTIONS OF PERSONAL COAL-MINE DUST EXPOSURES
    SEIXAS, NS
    HEWETT, P
    ROBINS, TG
    HANEY, R
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1995, 56 (03): : 243 - 250
  • [42] Toxicity and occupational health hazards of coal fly ash (CFA). A review of data and comparison to coal mine dust
    Borm, PJA
    ANNALS OF OCCUPATIONAL HYGIENE, 1997, 41 (06): : 659 - 676
  • [43] The effect of coal particle size on colorimetric analysis of roadway dust
    Kizil, MS
    Peterson, J
    English, W
    JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2001, 14 (05) : 387 - 394
  • [44] A CRITIQUE OF MSHA PROCEDURES FOR DETERMINATION OF PERMISSIBLE RESPIRABLE COAL-MINE DUST CONTAINING FREE SILICA
    CORN, M
    BREYSSE, P
    HALL, T
    CHEN, G
    RISBY, T
    SWIFT, DL
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1985, 46 (01): : 4 - 8
  • [45] Analysis on the Development Status of Coal Mine Dust Disaster Prevention Technology in China
    Zhang, Hui
    Han, Weihai
    Xu, Youlin
    Wang, Zhenfeng
    JOURNAL OF HEALTHCARE ENGINEERING, 2021, 2021
  • [46] A comparison of international silica (α-quartz) calibration standards by Fourier-Transform Infrared Spectrophotometry
    Verma, DK
    Shaw, DS
    ANNALS OF OCCUPATIONAL HYGIENE, 2001, 45 (06): : 429 - 435
  • [47] QUANTITATIVE-DETERMINATION OF CRYSTALLINE SILICA IN RESPIRABLE-SIZE DUST SAMPLES BY INFRARED SPECTROPHOTOMETRY
    FOSTER, RD
    WALKER, RF
    ANALYST, 1984, 109 (09) : 1117 - 1127
  • [48] A comparison of calibration procedures for the analysis of broad molecular weight distributions using size exclusion chromatography with multiple detection
    Zammit, MD
    Davis, TP
    POLYMER, 1997, 38 (17) : 4455 - 4468
  • [49] Adhesion Behavior of Underground Coal Dust with Fused Silica: Effects of Relative Humidity and Particle Size
    Zhou, Shujun
    Yang, Yue
    Shang, Hongfei
    PROCESSES, 2024, 12 (04)
  • [50] Comparison of Respirable Coal Mine Dust Constituents Estimated using FTIR, TGA, and SEM–EDX
    Nishan Pokhrel
    Eleftheria Agioutanti
    Cigdem Keles
    Setareh Afrouz
    Emily Sarver
    Mining, Metallurgy & Exploration, 2022, 39 : 291 - 300