Interstudy reproducibility of dark blood high-resolution MRI in evaluating basilar atherosclerotic plaque at 3 Tesla

被引:9
|
作者
Chen, Luguang [1 ]
Liu, Qi [1 ]
Shi, Zhang [1 ]
Tian, Xia [1 ]
Peng, Wenjia [1 ]
Lu, Jianping [1 ]
机构
[1] Second Mil Med Univ, Changhai Hosp Shanghai, Dept Radiol, Shanghai, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
ISOLATED PONTINE INFARCTION; INTRACRANIAL VESSEL WALL; CAROTID ATHEROSCLEROSIS; INVERSION-RECOVERY; ARTERY-STENOSIS; SCAN-RESCAN; 3.0; T; SEQUENCE; DISEASE; VISUALIZATION;
D O I
10.5152/dir.2018.17373
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE We aimed to evaluate the interscan, intraobserver, and interobserver reproducibility of basilar atherosclerotic plaque employing dark blood high-resolution magnetic resonance imaging (HR-MRI) at 3 Tesla. METHODS Sixteen patients (14 males and 2 females) with > 30% basilar stenosis as identified by conventional magnetic resonance angiography were prospectively recruited for scan and rescan examinations on a 3 Tesla MRI system using T2-weighted turbo spin-echo protocol. Two observers independently measured the areas of vessels and lumens. Wall area was derived by subtracting the lumen area from the vessel area. Areas of vessels, lumens and walls were compared for the evaluation of interscan variability of basilar plaque. To assess the intraobserver variability, one observer reevaluated all the images of the first scan after a 4-week interval. RESULTS Fourteen patients were included in the final analysis. No clinically significant difference was observed for interscan, intraobserver, and interobserver measurements. The intraclass correlations for vessel, lumen, and wall areas were excellent and ranged from 0.973 to 0.981 for the interscan measurements, 0.997 to 0.998 for the intraobserver measurements and 0.979 to 0.985 for the interobserver measurements. The coefficients of variation for quantitative basilar morphology measurements were 4.31%-10.35% for the interscan measurements, 1.41%-4.62% for the intraobserver measurements and 3.79%-8.46% for the interobserver measurements. Compared with the interscan and interobserver measurements, narrow intervals of the scatterplots were observed for the intraobserver measurements by Bland-Altman plots. CONCLUSION Basilar atherosclerotic plaque imaging demonstrates excellent reproducibility at 3 Tesla. The study proves that dark blood HR-MRI may serve as a reliable tool for clinical studies focused on the progression and treatment response of basilar atherosclerosis.
引用
收藏
页码:237 / 242
页数:6
相关论文
共 50 条
  • [41] Case Report: Advantages of High-Resolution MRI in Evaluating the Efficacy of Drug Therapy for Intracranial Atherosclerotic Plaques
    Zheng, Tao
    Liu, Lei
    Li, Li
    Gao, Yang
    Guo, Runcai
    Zhou, Zhi
    Liu, Zunjing
    Liu, Kunpeng
    FRONTIERS IN AGING NEUROSCIENCE, 2022, 14
  • [42] Identification and Quantitative Assessment of Different Components of Intracranial Atherosclerotic Plaque by Ex Vivo 3T High-Resolution Multicontrast MRI
    Jiang, Y.
    Peng, W.
    Tian, B.
    Zhu, C.
    Chen, L.
    Wang, X.
    Liu, Q.
    Wang, Y.
    Xiang, Z.
    Degnan, A. J.
    Teng, Z.
    Saloner, D.
    Lu, J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (09) : 1716 - 1722
  • [43] High-resolution cine MRI with TGRAPPA for fast assessment of left ventricular function at 3 Tesla
    Theisen, Daniel
    Sandner, Torleif A.
    Bamberg, Fabian
    Bauner, Kerstin U.
    Schwab, Felix
    Schwarz, Florian
    Arnoldi, Elisabeth
    Reiser, Maximilian F.
    Wintersperger, Bernd J.
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (05) : E219 - E224
  • [44] Feasibility of high-resolution perfusion imaging using arterial spin labeling MRI at 3 Tesla
    Kashyap, Sriranga
    Oliveira, icaro Agenor Ferreira
    Uludag, Kamil
    FRONTIERS IN PHYSIOLOGY, 2024, 14
  • [45] Carotid plaque high-resolution MRI at 3 T: evaluation of a new imaging score for symptomatic plaque assessment
    Gury-Paquet, Laurence
    Millon, Antoine
    Salami, Fatima
    Cemicanu, Alexandru
    Scoazec, Jean-Yves
    Douek, Philippe
    Boussel, Loic
    MAGNETIC RESONANCE IMAGING, 2012, 30 (10) : 1424 - 1431
  • [46] A High-Resolution MRI Study of the Relationship Between Plaque Enhancement and Ischemic Stroke Events in Patients With Intracranial Atherosclerotic Stenosis
    Wang, ErLing
    Shao, Sai
    Li, Shan
    Yan, Peng
    Xiang, YuanYuan
    Wang, Xiang
    Li, JiFeng
    Wang, Guangbin
    Sun, QinJian
    Du, YiFeng
    FRONTIERS IN NEUROLOGY, 2019, 9
  • [47] Temporal Dynamics of Symptomatic Intracranial Atherosclerotic Plaque Post Contrast Enhancement. A Serial High-resolution MRI Study
    Carbayo, Alvaro
    Martinez-Velasco, Elena
    Rodriguez-Velasco, Margarita
    Usero, Maria
    Calleja, Ana
    Cortijo, Elisa
    De Lera, Mercedes
    Reyes, Javier
    Munoz, Pedro
    Arenillas, Juan F.
    STROKE, 2017, 48
  • [48] High-resolution MRI with cardiac and respiratory gating allows for accurate in vivo atherosclerotic plaque visualization in the murine aortic arch
    Wiesmann, F
    Szimtenings, M
    Frydrychowicz, A
    Illinger, R
    Hunecke, A
    Rommel, E
    Neubauer, S
    Haase, A
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (01) : 69 - 74
  • [49] High resolution MRI anatomy of the cat brain at 3 Tesla
    Gray-Edwards, Heather L.
    Salibi, Nouha
    Josephson, Eleanor M.
    Hudson, Judith A.
    Cox, Nancy R.
    Randle, Ashley N.
    McCurdy, Victoria J.
    Bradbury, Allison M.
    Wilson, Diane U.
    Beyers, Ronald J.
    Denney, Thomas S.
    Martin, Douglas R.
    JOURNAL OF NEUROSCIENCE METHODS, 2014, 227 : 10 - 17
  • [50] Temporal evolution of symptomatic intracranial atherosclerotic plaque post-contrast enhancement: A serial high-resolution MRI study
    Martinez-Velasco, E.
    Margarita Rodriguez-Velasco, M.
    Calleja, A. I.
    Elisa Cortijo, E. C.
    Luis Lopez-Mesonero, L.
    Pablo Garcia-Bermejo, P.
    Maria Hernandez, M.
    Josep Munuera, J.
    Arenillas, J. F.
    INTERNATIONAL JOURNAL OF STROKE, 2015, 10 : 319 - 319