Interstudy reproducibility of dark blood high-resolution MRI in evaluating basilar atherosclerotic plaque at 3 Tesla

被引:9
|
作者
Chen, Luguang [1 ]
Liu, Qi [1 ]
Shi, Zhang [1 ]
Tian, Xia [1 ]
Peng, Wenjia [1 ]
Lu, Jianping [1 ]
机构
[1] Second Mil Med Univ, Changhai Hosp Shanghai, Dept Radiol, Shanghai, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
ISOLATED PONTINE INFARCTION; INTRACRANIAL VESSEL WALL; CAROTID ATHEROSCLEROSIS; INVERSION-RECOVERY; ARTERY-STENOSIS; SCAN-RESCAN; 3.0; T; SEQUENCE; DISEASE; VISUALIZATION;
D O I
10.5152/dir.2018.17373
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE We aimed to evaluate the interscan, intraobserver, and interobserver reproducibility of basilar atherosclerotic plaque employing dark blood high-resolution magnetic resonance imaging (HR-MRI) at 3 Tesla. METHODS Sixteen patients (14 males and 2 females) with > 30% basilar stenosis as identified by conventional magnetic resonance angiography were prospectively recruited for scan and rescan examinations on a 3 Tesla MRI system using T2-weighted turbo spin-echo protocol. Two observers independently measured the areas of vessels and lumens. Wall area was derived by subtracting the lumen area from the vessel area. Areas of vessels, lumens and walls were compared for the evaluation of interscan variability of basilar plaque. To assess the intraobserver variability, one observer reevaluated all the images of the first scan after a 4-week interval. RESULTS Fourteen patients were included in the final analysis. No clinically significant difference was observed for interscan, intraobserver, and interobserver measurements. The intraclass correlations for vessel, lumen, and wall areas were excellent and ranged from 0.973 to 0.981 for the interscan measurements, 0.997 to 0.998 for the intraobserver measurements and 0.979 to 0.985 for the interobserver measurements. The coefficients of variation for quantitative basilar morphology measurements were 4.31%-10.35% for the interscan measurements, 1.41%-4.62% for the intraobserver measurements and 3.79%-8.46% for the interobserver measurements. Compared with the interscan and interobserver measurements, narrow intervals of the scatterplots were observed for the intraobserver measurements by Bland-Altman plots. CONCLUSION Basilar atherosclerotic plaque imaging demonstrates excellent reproducibility at 3 Tesla. The study proves that dark blood HR-MRI may serve as a reliable tool for clinical studies focused on the progression and treatment response of basilar atherosclerosis.
引用
收藏
页码:237 / 242
页数:6
相关论文
共 50 条
  • [21] Occurrence and staging of Hemorrhage in the advanced carotid atherosclerotic plaque: A comparison of histology and high-resolution MRI
    Chu, BC
    Kampschulte, A
    Ferguson, MS
    Kerwin, WS
    Yarnykh, VL
    O'Brien, KD
    Polissar, NL
    Hatsukami, TS
    Chun, Y
    CIRCULATION, 2003, 108 (17) : N - N
  • [22] Fenofibrate induces plaque regression in hypercholesterolemic atherosclerotic rabbits: In vivo demonstration by high-resolution MRI
    Corti, Roberto
    Osende, Julio
    Hutter, Randolph
    Viles-Gonzalez, Juan F.
    Zafar, Urooj
    Valdivieso, Carolina
    Mizsei, Gabor
    Fallon, John T.
    Fuster, Valentin
    Badimon, Juan J.
    ATHEROSCLEROSIS, 2007, 190 (01) : 106 - 113
  • [23] High-resolution lung MRI with Ultrashort-TE: 1.5 or 3 Tesla?
    Chassagnon, Guillaume
    Martin, Charlotte
    Ben Hassen, Wadie
    Freche, Gael
    Bennani, Souhail
    Morel, Baptiste
    Revel, Marie-Pierre
    MAGNETIC RESONANCE IMAGING, 2019, 61 : 97 - 103
  • [24] Vascular compression in glossopharyngeal neuralgia: demonstration by high-resolution MRI at 3 tesla
    Fischbach, F
    Lehmann, TN
    Ricke, J
    Bruhn, H
    NEURORADIOLOGY, 2003, 45 (11) : 810 - 811
  • [25] Vascular compression in glossopharyngeal neuralgia: demonstration by high-resolution MRI at 3 tesla
    F. Fischbach
    T. N. Lehmann
    J. Ricke
    H. Bruhn
    Neuroradiology, 2003, 45 : 810 - 811
  • [26] Plaque characteristics, burden and distribution assessment in an Asian population with high-resolution intracranial vessel wall imaging at 3 Tesla MRI
    Dieleman, N.
    Yang, W.
    Abrigo, J.
    Lee, K. L.
    Chu, C. W.
    van der Kolk, A. G.
    Siero, J. C. W.
    Wong, K. S.
    Hendrikse, J.
    Chen, X. Y.
    INTERNATIONAL JOURNAL OF STROKE, 2015, 10 : 310 - 311
  • [27] TECHNIQUES FOR HIGH-RESOLUTION MR-IMAGING OF ATHEROSCLEROTIC PLAQUE
    YUAN, C
    TSURUDA, JS
    BEACH, KN
    HAYES, CE
    FERGUSON, MS
    ALPERS, CE
    FOO, TK
    STRANDNESS, DE
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (01): : 43 - 49
  • [28] High-resolution magnetic resonance imaging of carotid atherosclerotic plaque
    Saam, T.
    Schoenberg, S. O.
    Hatsukami, T. S.
    Reiser, M.
    Yuan, C.
    Nikolaou, K.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2008, 180 (02): : 100 - 111
  • [29] High-resolution intravascular magnetic resonance quantification of atherosclerotic plaque at 3T
    Di Qian
    Paul A Bottomley
    Journal of Cardiovascular Magnetic Resonance, 14
  • [30] High-resolution intravascular magnetic resonance quantification of atherosclerotic plaque at 3T
    Qian, Di
    Bottomley, Paul A.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2012, 14