Performance Evaluation of an Adsorption Heat Pump System Using MSC-30/R1234yf Pair with the Impact of Thermal Masses

被引:3
|
作者
Seo, Sangwon [1 ]
Miksik, Frantisek [1 ,2 ]
Maeshiro, Yuta [1 ]
Thu, Kyaw [1 ,2 ]
Miyazaki, Takahiko [1 ,2 ]
机构
[1] Kyushu Univ, Fac Engn Sci, Dept Adv Environm Sci & Engn, Kasuga Koen 6-1, Kasuga, Fukuoka 8168580, Japan
[2] Kyushu Univ, Int Inst Carbon Neutral Energy Res I2CNER, Res Ctr Next Generat Refrigerant Properties NEXT, Nishi Ku, 744 Motooka, Fukuoka 8190395, Japan
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 05期
关键词
adsorption heat pump cycle; isotherm fitting; activated carbon; MSC-30; R1234yf; ACTIVATED CARBON; SILICA-GEL; THERMODYNAMIC PROPERTIES; PHYSICAL ADSORPTION; WATER-ADSORPTION; COMPOSITE; ADSORBENT; DIFLUOROMETHANE; SIMULATION; ISOTHERMS;
D O I
10.3390/app11052279
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this study, we evaluated the performance of low Global Warming Potential (GWP) refrigerant R1234yf on the activated carbon (MSC-30) for adsorption heating applications. The adsorption isotherms of MSC-30/R1234yf were measured using a constant-volume-variable-pressure (CVVP) method from very low relative pressure to the practical operating ranges. The data were fitted with several isotherm models using non-linear curve fitting. An improved equilibrium model was employed to investigate the influence of dead thermal masses, i.e., the heat exchanger assembly and the non-adsorbing part of the adsorbent. The model employed the model for the isosteric heat of adsorption where the adsorbed phase volume was accounted for. The performance of the heat pump was compared with MSC-30/R134a pair using the data from the literature. The analysis covered the desorption temperature ranging from 60 degrees C to 90 degrees C, with the evaporation temperature at 5 degrees C and the adsorption temperature and condensation temperature set to 30 degrees C. It was observed that the adsorption isotherms of R1234yf on MSC-30 were relatively lower than those of R134a by approximately 12%. The coefficient of performance (COP) of the selected pair was found to vary from 0.03 to 0.35 depending on the heat source temperature. We demonstrated that due to lower latent heat, MSC-30/R1234yf pair exhibits slightly lower cycle performance compared to the MSC-30/R134a pair. However, the widespread adaptation of environmentally friendly R1234yf in automobile heat pump systems may call for the implementation of adsorption systems such as the direct hybridization using a single refrigerant. The isotherm and performance data presented in this work will be essential for such applications.
引用
收藏
页码:1 / 25
页数:24
相关论文
共 50 条
  • [1] Performance evaluation of R1234yf heat pump system for an electric vehicle in cold climate
    Li, Wanyong
    Liu, Rui
    Liu, Yusheng
    Wang, Dandong
    Shi, Junye
    Chen, Jiangping
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 115 : 117 - 125
  • [2] Performance evaluation of an automotive air conditioning and heat pump system using R1234yf and R134a
    Aral, Mumin Celil
    Suhermanto, Mukhamad
    Hosoz, Murat
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2021, 27 (01) : 44 - 60
  • [3] Experimental energy and exergy performance of an automotive heat pump using R1234yf
    Alpaslan Alkan
    Ahmet Kolip
    Murat Hosoz
    Journal of Thermal Analysis and Calorimetry, 2021, 146 : 787 - 799
  • [4] Experimental energy and exergy performance of an automotive heat pump using R1234yf
    Alkan, Alpaslan
    Kolip, Ahmet
    Hosoz, Murat
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2021, 146 (02) : 787 - 799
  • [5] Comparative performance of an automobile heat pump system with an internal heat exchanger using R1234yf and R134a
    Tasdemirci, Erkutay
    Alptekin, Ertan
    Hosoz, Murat
    INTERNATIONAL JOURNAL OF EXERGY, 2020, 33 (01) : 98 - 113
  • [6] Comparative performance of an automobile heat pump system with an internal heat exchanger using R1234yf and R134a
    Tasdemirci E.
    Alptekin E.
    Hosoz M.
    International Journal of Exergy, 2020, 33 (01): : 98 - 113
  • [7] Experimental Evaluation of an Automotive Heat Pump System with R1234yf as an Alternative to R134a
    Direk, Mehmet
    Yuksel, Fikret
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2020, 45 (02) : 719 - 728
  • [8] Performance comparison of a direct heat pump using R1234yf and indirect heat pumps using R1234yf and R290 designed for cabin heating of electric vehicles
    Kwon, Soonbum
    Lee, Dongchan
    Chung, Jun Yeob
    Maeng, Heegyu
    Kim, Yongchan
    ENERGY, 2024, 297
  • [9] Experimental Evaluation of an Automotive Heat Pump System with R1234yf as an Alternative to R134a
    Mehmet Direk
    Fikret Yüksel
    Arabian Journal for Science and Engineering, 2020, 45 : 719 - 728
  • [10] Experimental Study on Heating Performance of an R1234yf Heat Pump System for Electric Cars
    Zou, Huiming
    Huang, Guangyan
    Shao, Shuangquan
    Zhang, Xiaoqiang
    Tian, Changqing
    Zhang, Xuelai
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY, 2017, 142 : 1015 - 1021