Resistive-nanoindentation: contact area monitoring by real-time electrical contact resistance measurement

被引:9
|
作者
Comby-Dassonneville, Solene [1 ]
Volpi, Fabien [1 ]
Parry, Guillaume [1 ]
Pellerin, Didier [2 ]
Verdier, Marc [1 ]
机构
[1] Univ Grenoble Alpes, CNRS, Grenoble INP, SIMaP, F-38000 Grenoble, France
[2] Scientec CSInstruments, F-91940 Les Ulis, France
关键词
ELASTIC-MODULUS; INSTRUMENTED INDENTATION; CONSTRICTION RESISTANCE; PHASE-TRANSFORMATIONS; METAL-SURFACES; MICROSCOPY; GERMANIUM; HARDNESS; SILICON; TIP;
D O I
10.1557/mrc.2019.74
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In the past decades, efforts have been made to couple nanoindentation with resistive measurements in order to monitor the real-time contact area, as an alternative to the use of traditional analytical models. In this work, a novel and efficient stand-alone method is proposed to compute the contact area using resistive-nanoindentation of noble metals (bulk or thin films). This method relies on three steps: tip shape measurement, set-up calibration, application to the sample to be characterized. The procedure is applied to nanoindentation tests on a sample with film-on-elastic-substrate rheology and is successfully validated against experimental measurements of the contact area.
引用
收藏
页码:1008 / 1014
页数:7
相关论文
共 50 条
  • [41] Soft Contact-lens Biosensor for Real-time Tear Sugar Monitoring at the Eye
    Kudo, Hiroyuki
    Chu, MingXing
    Miyajima, Kumiko
    Arakawa, Takahiro
    Mitsubayashi, Kohji
    Hiranuma, Yoshitaka
    Hiramatsu, Hideo
    PROCEEDINGS 2012 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2012, : 2048 - 2051
  • [42] Webcam Based Non-contact Real-time Monitoring for the Physiological Parameters of Drivers
    Zhang, Qi
    Xu, Guo-qing
    Wang, Ming
    Zhou, Yimin
    Feng, Wei
    2014 IEEE 4TH ANNUAL INTERNATIONAL CONFERENCE ON CYBER TECHNOLOGY IN AUTOMATION, CONTROL, AND INTELLIGENT SYSTEMS (CYBER), 2014, : 648 - 652
  • [43] Time-Dependent Electrical Contact Resistance at the Nanoscale
    Mohammad R. Vazirisereshk
    Saima A. Sumaiya
    Rimei Chen
    Mehmet Z. Baykara
    Ashlie Martini
    Tribology Letters, 2021, 69
  • [44] Non-contact Respiratory Monitoring based on Real-time IR-Thermography
    Abbas, Abbas K.
    Heiman, K.
    Orlikowsky, Th
    Leonhardt, Steffen
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 1306 - 1309
  • [45] A Real-Time and Non-contact Pulse Rate Measurement System on Fitness Equipment
    Chou, Yung-Chien
    Ye, Bo-Yi
    Chen, Hong-Ren
    Lin, Yuan-Hsiang
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [46] A non-contact real-time measurement of lamp dimension based on machine vision
    宋丽梅
    王朋强
    常玉兰
    李晓捷
    习江涛
    郭庆华
    李秉男
    OptoelectronicsLetters, 2015, 11 (02) : 145 - 148
  • [47] A non-contact real-time measurement of lamp dimension based on machine vision
    Song L.-M.
    Wang P.-Q.
    Chang Y.-L.
    Li X.-J.
    Xi J.-T.
    Guo Q.-H.
    Li B.-N.
    Optoelectronics Letters, 2015, 11 (02) : 145 - 148
  • [48] Non-Contact and Real-Time Measurement of Kolsky Bar with Temporal Speckle Interferometry
    Yang, Shanwei
    Gao, Zhan
    Ruan, Haihui
    Gao, Chenjia
    Wang, Xu
    Sun, Xiang
    Wen, Xin
    APPLIED SCIENCES-BASEL, 2018, 8 (05):
  • [49] Real-time contact angle's measurement of molten solder balls in laboratory conditions
    Dzivy, Daniel
    Pietrikova, Alena
    MICROELECTRONICS INTERNATIONAL, 2022, 39 (03) : 132 - 138
  • [50] Scanning control based on real-time contact force feedback for ultrasonic thickness measurement
    Liu, Haibo
    Li, Xu
    Bo, Qile
    Lian, Meng
    Li, Te
    Wang, Yongqing
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2021, 43 (11) : 2461 - 2471