Soft Contact-lens Biosensor for Real-time Tear Sugar Monitoring at the Eye

被引:0
|
作者
Kudo, Hiroyuki [1 ]
Chu, MingXing [1 ]
Miyajima, Kumiko [1 ]
Arakawa, Takahiro [1 ]
Mitsubayashi, Kohji [1 ]
Hiranuma, Yoshitaka [2 ]
Hiramatsu, Hideo [2 ]
机构
[1] Tokyo Med & Dent Univ, Inst Biomat & Bioengn, Tokyo, Japan
[2] Nihon Univ, Grad Sch Ind Technol, Chiba, Japan
基金
日本学术振兴会;
关键词
glucose; biosensor; monitoring; continuous; tear; GLUCOSE;
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
A soft contact-lens (SCL) biosensor for in-situ tear sugar monitoring was fabricated and tested. In contrast to the previously reported continuous glucose monitoring (CGM) devices, we focused on the relationship between blood glucose and tear glucose. The SCL biosensor was constructed by applying microelectromechanical systems (MEMS) techniques to functional polymers. The sensor has film electrodes on the surface of a rounded surface of polydimethyl siloxane (PDMS) contact-lens and glucose oxidase (GOD) was immobilized on the sensing region of the electrodes. Sufficiently adhesive and flexible electrodes were formed on the polymer device (PDMS and 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer). In the in-vitro characterization, the SCL-biosensor showed excellent relationship between the output current and glucose concentration from 0.03 to 10.0 mmol/L, which included the reported tear glucose concentrations (0.14 mM) of humans. Based on the result, in-situ tear glucose monitoring with the SCL-biosensor was carried out. The output current of the SCL-biosensor was sufficiently stable and reflected the tear glucose levels. The static glucose level in the basal tear of a rabbit was measured and estimated to 0.13 mmol/L. Since the biosensor was also possible to be sotored for more than 50 days, daily disposable application was expected with the SCL biosensor.
引用
收藏
页码:2048 / 2051
页数:4
相关论文
共 50 条
  • [1] Development of a Soft Contact-Lens Biosensor for In-vivo Tear Glucose Monitoring
    Chu, M. K.
    Iguchi, S.
    Miyajima, K.
    Arakawa, T.
    Kudo, H.
    Mitsubayashi, K.
    5TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2012, 37 : 1007 - +
  • [2] Development of a soft contact-lens biosensor for in-vivo tear glucose monitoring
    Chu, M.K.
    Iguchi, S.
    Miyajima, K.
    Arakawa, T.
    Kudo, H.
    Mitsubayashi, K.
    IFMBE Proceedings, 2011, 37 : 1007 - 1010
  • [3] Status of Soft Contact Lens Biosensor Development for Tear Sugar Monitoring: A Review
    Kudo, Hiroyuki
    Arakawa, Takahiro
    Mitsubayashi, Kohji
    ELECTRONICS AND COMMUNICATIONS IN JAPAN, 2014, 97 (12) : 52 - 56
  • [4] Novel biosensing devices for medical applications Soft contact-lens sensors for monitoring tear sugar
    Mitsubayashi, Kohji
    2014 INTERNATIONAL CONFERENCE ON SIMULATION OF SEMICONDUCTOR PROCESSES AND DEVICES (SISPAD), 2014, : 349 - 352
  • [5] Status of soft-contact lens biosensor development towards tear sugar monitoring: A review
    Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, 2-3-10, Kanda-Surugarai, Chiyoda-ku, Tokyo 101-0062, Japan
    IEEJ Trans. Sens. Micromach., 12 (451-454):
  • [6] Soft contact lens biosensor for in situ monitoring of tear glucose as non-invasive blood sugar assessment
    Chu, Ming Xing
    Miyajima, Kumiko
    Takahashi, Daishi
    Arakawa, Takahiro
    Sano, Kenji
    Sawada, Shin-ichi
    Kudo, Hiroyuki
    Iwasaki, Yasuhiko
    Akiyoshi, Kazunari
    Mochizuki, Manabu
    Mitsubayashi, Kohji
    TALANTA, 2011, 83 (03) : 960 - 965
  • [7] OXYGEN FLUX THROUGH A SOFT CONTACT-LENS ON THE EYE
    RASSON, JE
    FATT, I
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1982, 59 (03): : 203 - 212
  • [8] TEAR FILM PHYSIOLOGY AND CONTACT-LENS WEAR .2. CONTACT-LENS TEAR FILM INTERACTION
    HOLLY, FJ
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1981, 58 (04): : 331 - 341
  • [9] EYE TEAR RESPONSE TO CONTACT-LENS STUDIED BY WILHELMY PLATE TECHNIQUE
    ZHANG, HJ
    LEAHY, CD
    ELLIS, J
    ELLIS, E
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 1293 - 1293
  • [10] LUBRICATION THEORY MODEL OF TEAR EXCHANGE UNDER A SOFT CONTACT-LENS
    HAYASHI, T
    FATT, I
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1976, 53 (03): : 101 - 103