Development of a Soft Contact-Lens Biosensor for In-vivo Tear Glucose Monitoring

被引:0
|
作者
Chu, M. K. [1 ]
Iguchi, S. [1 ]
Miyajima, K. [1 ]
Arakawa, T. [1 ]
Kudo, H. [1 ]
Mitsubayashi, K. [1 ]
机构
[1] Tokyo Med & Dent Univ, Inst Biomat & Bioengn, Chiyoda Ku, 1BB,2-3-10 Kanda Surugadai, Tokyo, Japan
基金
日本学术振兴会;
关键词
Soft contact-lens biosensor; tear glucose; non-invasive; monitoring; diabetes; SENSOR;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A wearable amperometric glucose sensor was fabricated and tested for development of a soft contact-lens biosensor for in-vivo tear glucose monitoring. The sensor was constructed by immobilizing GOD onto a flexible oxygen electrode, which was fabricated using "Soft-MEMS" techniques onto a functional polymer membrane. In purpose of bioinstrumentation, adhesive agents were not used for constructing the flexible biosensor. Linear relationship between glucose concentration and output current was obtained in a range of 0.039 - 0.537 mmol/l. Current dependences on pH and temperature were also evaluated. The current was largest at pH 7.0 and the current increased when temperature increased. This indicates that the output current depends on enzyme activity. Based on the basic characteristics investigation, the glucose sensor was applied to measurement of glucose in tear fluids on an eye site of a Japan white rabbit. The change of tear glucose level induced by oral-administration of glucose was monitored as a current change of the sensor attached on the eye site. In this investigation, the tear glucose level varied from 0.2 mmol/l to 0.5 mmol/l. Although there was a delay of several tens of minutes towards blood sugar level, it is considered to be possible that non-invasive continuous glucose monitoring can be realized using the flexible biosensor.
引用
收藏
页码:1007 / +
页数:2
相关论文
共 50 条
  • [1] Development of a soft contact-lens biosensor for in-vivo tear glucose monitoring
    Chu, M.K.
    Iguchi, S.
    Miyajima, K.
    Arakawa, T.
    Kudo, H.
    Mitsubayashi, K.
    IFMBE Proceedings, 2011, 37 : 1007 - 1010
  • [2] Soft Contact-lens Biosensor for Real-time Tear Sugar Monitoring at the Eye
    Kudo, Hiroyuki
    Chu, MingXing
    Miyajima, Kumiko
    Arakawa, Takahiro
    Mitsubayashi, Kohji
    Hiranuma, Yoshitaka
    Hiramatsu, Hideo
    PROCEEDINGS 2012 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2012, : 2048 - 2051
  • [3] Status of Soft Contact Lens Biosensor Development for Tear Sugar Monitoring: A Review
    Kudo, Hiroyuki
    Arakawa, Takahiro
    Mitsubayashi, Kohji
    ELECTRONICS AND COMMUNICATIONS IN JAPAN, 2014, 97 (12) : 52 - 56
  • [4] Status of soft-contact lens biosensor development towards tear sugar monitoring: A review
    Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, 2-3-10, Kanda-Surugarai, Chiyoda-ku, Tokyo 101-0062, Japan
    IEEJ Trans. Sens. Micromach., 12 (451-454):
  • [5] A 3-μW CMOS Glucose Sensor for Wireless Contact-Lens Tear Glucose Monitoring
    Liao, Yu-Te
    Yao, Huanfen
    Lingley, Andrew
    Parviz, Babak
    Otis, Brian P.
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2012, 47 (01) : 335 - 344
  • [6] A SOFT HYDROGEL CONTACT LENS WITH AN ENCAPSULATED SENSOR FOR TEAR GLUCOSE MONITORING
    Yao, H.
    Marcheselli, C.
    Afanasiev, A.
    Laehdesmaeki, I.
    Parviz, B. A.
    2012 IEEE 25TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2012,
  • [7] Soft contact lens biosensor for in situ monitoring of tear glucose as non-invasive blood sugar assessment
    Chu, Ming Xing
    Miyajima, Kumiko
    Takahashi, Daishi
    Arakawa, Takahiro
    Sano, Kenji
    Sawada, Shin-ichi
    Kudo, Hiroyuki
    Iwasaki, Yasuhiko
    Akiyoshi, Kazunari
    Mochizuki, Manabu
    Mitsubayashi, Kohji
    TALANTA, 2011, 83 (03) : 960 - 965
  • [8] Novel biosensing devices for medical applications Soft contact-lens sensors for monitoring tear sugar
    Mitsubayashi, Kohji
    2014 INTERNATIONAL CONFERENCE ON SIMULATION OF SEMICONDUCTOR PROCESSES AND DEVICES (SISPAD), 2014, : 349 - 352
  • [9] USE OF SOFT CONTACT-LENS FOR IN-VIVO STUDY OF THE CORNEA USING TANDEM CONFOCAL MICROSCOPE
    MAMDAN, TT
    DAUB, RR
    NODA, R
    SONI, PS
    HORNER, DG
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S312 - S312
  • [10] MICRODIALYSIS AND GLUCOSE BIOSENSOR FOR IN-VIVO MONITORING
    MOSCONE, D
    MASCINI, M
    ANNALES DE BIOLOGIE CLINIQUE, 1992, 50 (05) : 323 - 327