Agility MLC transmission optimization in the Monaco treatment planning system

被引:15
|
作者
Roche, Michael [1 ]
Crane, Robert [1 ]
Powers, Marcus [1 ]
Crabtree, Timothy [1 ]
机构
[1] Townsville Canc Ctr, Dept Med Phys, Douglas, Qld, Australia
来源
关键词
Agility MLC; MLC transmission; Monaco; TPF; TPS; MULTILEAF COLLIMATOR; DOSE CALCULATION; SOURCE MODEL; BLOCKS; BEAM; IMRT;
D O I
10.1002/acm2.12399
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The Monaco Monte Carlo treatment planning system uses three-beam model components to achieve accuracy in dose calculation. These components include a virtual source model (VSM), transmission probability filters (TPFs), and an x-ray voxel Monte Carlo (XVMC) engine to calculate the dose in the patient. The aim of this study was to assess the TPF component of the Monaco TPS and optimize the TPF parameters using measurements from an Elekta linear accelerator with an Agility (TM) multileaf collimator (MLC). The optimization began with all TPF parameters set to their default value. The function of each TPF parameter was characterized and a value was selected that best replicated measurements with the Agility (TM) MLC. Both vendor provided fields and a set of additional test fields were used to create a rigorous systematic process, which can be used to optimize the TPF parameters. It was found that adjustment of the TPF parameters based on this process resulted in improved point dose measurements and improved 3D gamma analysis pass rates with Octavius 4D. All plans calculated with the optimized beam model had a gamma pass rate of > 95% using criteria of 2% global dose/2 mm distance-to-agreement, while some plans calculated with the default beam model had pass rates as low as 88.4%. For measured point doses, the improvement was particularly noticeable in the low-dose regions of the clinical plans. In these regions, the average difference from the planned dose reduced from 4.4 +/- 4.5% to 0.9 +/- 2.7% with a coverage factor (k = 2) using the optimized beam model. A step-by-step optimization guide is provided at the end of this study to assist in the optimization of the TPF parameters in the Monaco TPS. Although it is possible to achieve good clinical results by randomly selecting TPF parameter values, it is recommended that the optimization process outlined in this study is followed so that the transmission through the TPF is characterized appropriately.
引用
收藏
页码:473 / 482
页数:10
相关论文
共 50 条
  • [1] Transmission probability filter optimization for Agility MLC in Monaco treatment planning system
    Thewes, Lena
    Eckl, Miriam
    Schneider, Frank
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (09):
  • [2] Modeling the Agility MLC in the Monaco treatment planning system
    Snyder, Michael
    Halford, Robert
    Knill, Cory
    Adams, Jeffrey N.
    Bossenberger, Todd
    Nalichowski, Adrian
    Hammoud, Ahmad
    Burmeister, Jay
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (03): : 190 - 202
  • [3] Optimizing Agility MLC model in the Monaco treatment planning system
    Miguel, F. San
    Chamorro, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1316 - S1317
  • [4] Dosimetric comparison of Thoracic SBRT planning in Monaco and Eclipse for the Elekta Agility MLC
    Villamizar, R. J. Plata
    Ribeiro, M.
    Torzsok, C. K.
    Broque, H.
    Ruiz, A.
    Rodriguez-Mongua, J. L.
    Aponte, J.
    Marangoni, F.
    Pino, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1781 - S1782
  • [5] Modelling the MLC Agility transmission radiation through the closed leaf gap in the Monaco TPS
    Vicedo Gonzalez, M. A.
    Garcia Hernandez, M. T.
    Planes Meseguer, D.
    Garcia Molla, R.
    Borderia Navarro, B.
    Calatayud Cuesta, P.
    Alcaraz Lozano, M. L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1296 - S1297
  • [6] Monaco treatment planning system tools and optimization processes
    Clements, Mac
    Schupp, Nicholas
    Tattersall, Megan
    Brown, Anthony
    Larson, Randy
    [J]. MEDICAL DOSIMETRY, 2018, 43 (02) : 106 - 117
  • [7] A Test Suite for Optimization and Verification of MLC Treatment Planning System Modeling
    Popple, R.
    Barnes, M.
    Covington, E.
    Farrey, K.
    Moran, J.
    Perez, M.
    Raxter, D.
    Ritter, T.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2968 - 2968
  • [8] Case Studies with the Monaco Treatment Planning System
    Culberson, W.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [9] Treatment couch modeling in Elekta Monaco treatment planning system
    Huertas, C.
    Ferrer, C.
    Huerga, C.
    Mas, I.
    Serrada, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S389 - S390
  • [10] Initial Experience with the Monaco IMRT Treatment Planning System
    Reitz, B.
    Gayou, O.
    Parda, D.
    Miften, M.
    [J]. MEDICAL PHYSICS, 2008, 35 (06) : 2986 - +