Agility MLC transmission optimization in the Monaco treatment planning system

被引:15
|
作者
Roche, Michael [1 ]
Crane, Robert [1 ]
Powers, Marcus [1 ]
Crabtree, Timothy [1 ]
机构
[1] Townsville Canc Ctr, Dept Med Phys, Douglas, Qld, Australia
来源
关键词
Agility MLC; MLC transmission; Monaco; TPF; TPS; MULTILEAF COLLIMATOR; DOSE CALCULATION; SOURCE MODEL; BLOCKS; BEAM; IMRT;
D O I
10.1002/acm2.12399
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The Monaco Monte Carlo treatment planning system uses three-beam model components to achieve accuracy in dose calculation. These components include a virtual source model (VSM), transmission probability filters (TPFs), and an x-ray voxel Monte Carlo (XVMC) engine to calculate the dose in the patient. The aim of this study was to assess the TPF component of the Monaco TPS and optimize the TPF parameters using measurements from an Elekta linear accelerator with an Agility (TM) multileaf collimator (MLC). The optimization began with all TPF parameters set to their default value. The function of each TPF parameter was characterized and a value was selected that best replicated measurements with the Agility (TM) MLC. Both vendor provided fields and a set of additional test fields were used to create a rigorous systematic process, which can be used to optimize the TPF parameters. It was found that adjustment of the TPF parameters based on this process resulted in improved point dose measurements and improved 3D gamma analysis pass rates with Octavius 4D. All plans calculated with the optimized beam model had a gamma pass rate of > 95% using criteria of 2% global dose/2 mm distance-to-agreement, while some plans calculated with the default beam model had pass rates as low as 88.4%. For measured point doses, the improvement was particularly noticeable in the low-dose regions of the clinical plans. In these regions, the average difference from the planned dose reduced from 4.4 +/- 4.5% to 0.9 +/- 2.7% with a coverage factor (k = 2) using the optimized beam model. A step-by-step optimization guide is provided at the end of this study to assist in the optimization of the TPF parameters in the Monaco TPS. Although it is possible to achieve good clinical results by randomly selecting TPF parameter values, it is recommended that the optimization process outlined in this study is followed so that the transmission through the TPF is characterized appropriately.
引用
收藏
页码:473 / 482
页数:10
相关论文
共 50 条
  • [41] Modeling of couch transmission in the RayStation treatment planning system
    Savini, Alessandro
    Bartolucci, Floriana
    Fidanza, Christian
    Rosica, Federica
    Orlandi, Giovanni
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (05): : 735 - 740
  • [42] Simulated Tumor Tracking in An MRI Linac for Lung Tumor Lesions Using the Monaco Treatment Planning System
    Al-Ward, S.
    Kim, A.
    McCann, C.
    Ruschin, M.
    Cheung, P.
    Sahgal, A.
    Keller, B.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3855 - 3855
  • [44] Carbon-Fiber Couch Modeling Optimization for Monaco VMAT Planning and Delivery
    Tanooka, M.
    Inoue, H.
    Doi, H.
    Miura, H.
    Takada, Y.
    Fujiwara, M.
    Ishimaru, F.
    Sakamoto, K.
    Kamikonya, N.
    Hirota, S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S747 - S748
  • [45] Verification of a rounded leaf-end MLC model used in a radiotherapy treatment planning system
    Williams, MJ
    Metcalfe, P
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (04): : N65 - N78
  • [46] Independent validation of CORVUS MLC IMRT dose distributions using ADAC treatment planning system
    Ayyangar, KM
    Saw, CB
    Yoe-Sein, M
    Zhen, W
    Raman, N
    Enke, CA
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1271 - 1272
  • [47] Dosimetry Heiner fields and validation of the Siemens 160 MLC™ for the iPlan treatment planning system (BrainLAB)
    Senz, S.
    Walke, M.
    Gademann, G.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 : 164 - 164
  • [48] Review and prospect of robust optimization and planning research on generation and transmission system
    Yuan, Yang
    Zhang, Heng
    Cheng, Haozhong
    Liu, Lu
    Zhang, Xiaohu
    Li, Gang
    Zhang, Jianping
    [J]. Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2022, 42 (01): : 10 - 19
  • [49] Analysis of three optimization techniques in a treatment planning system
    Hu, Z
    Chu, J
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1954 - 1954
  • [50] Automated Two Loop Optimization of a Treatment Planning System
    Wang, H.
    Xing, L.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3281 - 3281