Transmission probability filter optimization for Agility MLC in Monaco treatment planning system

被引:1
|
作者
Thewes, Lena [1 ]
Eckl, Miriam [1 ]
Schneider, Frank [1 ,2 ]
机构
[1] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Radiat Oncol, Mannheim, Germany
[2] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Radiat Oncol, Theodor-Kutzer Ufer 1-3, D-68167 Mannheim, Germany
来源
关键词
MLC transmission in Monaco TPS; transmission probability filters; SOURCE MODEL;
D O I
10.1002/acm2.14105
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In the Monte Carlo-based treatment planning system (TPS) Monaco, transmission probability filters (TPF) are utilized to describe the transmission through the multi leaf collimator (MLC). By having knowledge of the TPF parameters for various photon beam energies, adjusting the MLC transmission parameters becomes easier, enhancing the accuracy of the Monte Carlo algorithm in achieving a dose distribution that closely aligns with the irradiated dose at the Versa HD linear accelerator (linac). The objective of this study was to determine the TPF parameters for 6MV, 10MV, 6MV flattening filter free (FFF) and 10MV FFF for a Versa HD linac equipped with Agility MLC. The TPF parameters were adjusted using point dose measurements and vendor-provided fields specifically designed to fine-tune the MLC. After adjusting the TPF parameters, a gamma passing rate (GPR) analysis was conducted on 25 treatment plans to ensure that the Monte Carlo model, with the updated TPF parameters, accurately matched the actual linac delivery. The TPF values ranged from 0.0018 to 0.0032 for leaf transmission and 1.15 to 1.25 for Leaf Tip leakage across the different energies. The average GPR ranged from 97.8% for 10MV FFF to 98.5% for 6MV photon energies. Additionally, the TPF parameters for 6MV obtained in this study were consistent with previously published TPF values for 6MV photon energy. Hence, it was concluded that optimizing the TPF does not need to be performed for every individual Versa HD linac with Agility MLC. Instead, the published parameters can be applied to other Versa HD linacs to enhance clinical accuracy. In conclusion, this study determined the TPF parameters for 6MV and previously unpublished photon energies 10MV, 6MV FFF and 10MV FFF. These parameters can be easily transferred to other facilities, resulting in improved agreement between the dose distribution from the TPS and the linac.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Agility MLC transmission optimization in the Monaco treatment planning system
    Roche, Michael
    Crane, Robert
    Powers, Marcus
    Crabtree, Timothy
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (05): : 473 - 482
  • [2] Modeling the Agility MLC in the Monaco treatment planning system
    Snyder, Michael
    Halford, Robert
    Knill, Cory
    Adams, Jeffrey N.
    Bossenberger, Todd
    Nalichowski, Adrian
    Hammoud, Ahmad
    Burmeister, Jay
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (03): : 190 - 202
  • [3] Optimizing Agility MLC model in the Monaco treatment planning system
    Miguel, F. San
    Chamorro, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1316 - S1317
  • [4] Dosimetric comparison of Thoracic SBRT planning in Monaco and Eclipse for the Elekta Agility MLC
    Villamizar, R. J. Plata
    Ribeiro, M.
    Torzsok, C. K.
    Broque, H.
    Ruiz, A.
    Rodriguez-Mongua, J. L.
    Aponte, J.
    Marangoni, F.
    Pino, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1781 - S1782
  • [5] Modelling the MLC Agility transmission radiation through the closed leaf gap in the Monaco TPS
    Vicedo Gonzalez, M. A.
    Garcia Hernandez, M. T.
    Planes Meseguer, D.
    Garcia Molla, R.
    Borderia Navarro, B.
    Calatayud Cuesta, P.
    Alcaraz Lozano, M. L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1296 - S1297
  • [6] Monaco treatment planning system tools and optimization processes
    Clements, Mac
    Schupp, Nicholas
    Tattersall, Megan
    Brown, Anthony
    Larson, Randy
    [J]. MEDICAL DOSIMETRY, 2018, 43 (02) : 106 - 117
  • [7] A Test Suite for Optimization and Verification of MLC Treatment Planning System Modeling
    Popple, R.
    Barnes, M.
    Covington, E.
    Farrey, K.
    Moran, J.
    Perez, M.
    Raxter, D.
    Ritter, T.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2968 - 2968
  • [8] Case Studies with the Monaco Treatment Planning System
    Culberson, W.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [9] Treatment couch modeling in Elekta Monaco treatment planning system
    Huertas, C.
    Ferrer, C.
    Huerga, C.
    Mas, I.
    Serrada, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S389 - S390
  • [10] Initial Experience with the Monaco IMRT Treatment Planning System
    Reitz, B.
    Gayou, O.
    Parda, D.
    Miften, M.
    [J]. MEDICAL PHYSICS, 2008, 35 (06) : 2986 - +