Transmission probability filter optimization for Agility MLC in Monaco treatment planning system

被引:1
|
作者
Thewes, Lena [1 ]
Eckl, Miriam [1 ]
Schneider, Frank [1 ,2 ]
机构
[1] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Radiat Oncol, Mannheim, Germany
[2] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Radiat Oncol, Theodor-Kutzer Ufer 1-3, D-68167 Mannheim, Germany
来源
关键词
MLC transmission in Monaco TPS; transmission probability filters; SOURCE MODEL;
D O I
10.1002/acm2.14105
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In the Monte Carlo-based treatment planning system (TPS) Monaco, transmission probability filters (TPF) are utilized to describe the transmission through the multi leaf collimator (MLC). By having knowledge of the TPF parameters for various photon beam energies, adjusting the MLC transmission parameters becomes easier, enhancing the accuracy of the Monte Carlo algorithm in achieving a dose distribution that closely aligns with the irradiated dose at the Versa HD linear accelerator (linac). The objective of this study was to determine the TPF parameters for 6MV, 10MV, 6MV flattening filter free (FFF) and 10MV FFF for a Versa HD linac equipped with Agility MLC. The TPF parameters were adjusted using point dose measurements and vendor-provided fields specifically designed to fine-tune the MLC. After adjusting the TPF parameters, a gamma passing rate (GPR) analysis was conducted on 25 treatment plans to ensure that the Monte Carlo model, with the updated TPF parameters, accurately matched the actual linac delivery. The TPF values ranged from 0.0018 to 0.0032 for leaf transmission and 1.15 to 1.25 for Leaf Tip leakage across the different energies. The average GPR ranged from 97.8% for 10MV FFF to 98.5% for 6MV photon energies. Additionally, the TPF parameters for 6MV obtained in this study were consistent with previously published TPF values for 6MV photon energy. Hence, it was concluded that optimizing the TPF does not need to be performed for every individual Versa HD linac with Agility MLC. Instead, the published parameters can be applied to other Versa HD linacs to enhance clinical accuracy. In conclusion, this study determined the TPF parameters for 6MV and previously unpublished photon energies 10MV, 6MV FFF and 10MV FFF. These parameters can be easily transferred to other facilities, resulting in improved agreement between the dose distribution from the TPS and the linac.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] A Dosimetric Comparison of Two Different Optimization Modes Used in Monaco Treatment Planning System During VMAT for Lung Cancer
    Chinnadaikkan, S.
    Palanisamy, M.
    Thangaraj, T.
    Bhalla, N.
    Puri, A.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E617 - E617
  • [22] Validation of Elekta couch modeling for dose calculation in the Monaco treatment planning system
    Poli, E.
    Reis, P.
    Prudencio, L.
    Galhardas, J.
    Ribeiro, T.
    Malveiro, R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S991 - S991
  • [23] Dose calculation using Monte Carlo algorithm of Monaco treatment planning system
    Li, J.
    Doemer, A.
    Harrison, A. S.
    Galvin, J. M.
    Xiao, Y.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S674 - S674
  • [24] DOSIMETRIC COMMISSIONING OF A MONTE CARLO MODEL IN THE ELEKTA MONACO TREATMENT PLANNING SYSTEM
    Hodgson, D.
    Convery, D.
    Greener, A.
    Misson-Yates, S.
    Thomas, C.
    Footman, M.
    Applegate, K.
    Harrison, L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S522 - S522
  • [25] The commissioning and validation of Monaco treatment planning system on an Elekta VersaHD linear accelerator
    Snyder, Jeffrey E.
    Hyer, Daniel E.
    Flynn, Ryan T.
    Boczkowski, Amanda
    Wang, Dongxu
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (01): : 184 - 193
  • [26] Dosimetric validation of Monaco treatment planning system on an Elekta VersaHD linear accelerator
    Narayanasamy, Ganesh
    Saenz, Daniel L.
    Defoor, Dewayne
    Papanikolaou, Niko
    Stathakis, Sotirios
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (06): : 123 - 129
  • [27] Optimizing the MLC Model Parameters for IMRT in the RayStation Treatment Planning System
    Chen, S.
    Yi, B.
    Xu, H.
    Yang, X.
    Prado, K.
    D' Souza, W.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 362 - +
  • [28] Commissioning of a commercial IMRT treatment planning system for standard elekta MLC
    Kim, H
    Chen, Y
    Xiao, Y
    Anne, P
    Galvin, J
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1348 - 1348
  • [29] Optimizing the MLC model parameters for IMRT in the RayStation treatment planning system
    Chen, Shifeng
    Yi, Byong Yong
    Yang, Xiaocheng
    Xu, Huijun
    Prado, Karl L.
    D'Souza, Warren D.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (05): : 322 - 332
  • [30] Quantification and Modelling of the Ionization Chamber Simulation Effective Points On Monaco Treatment Planning System
    Zhang, R.
    Bai, W.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3546 - 3546