Closed-loop control impact on the diagnosis of induction motors faults

被引:146
|
作者
Bellini, A [1 ]
Filippetti, F
Franceschini, G
Tassoni, C
机构
[1] Univ Parma, Dipartimento Ingn Informazione, I-43100 Parma, Italy
[2] Univ Bologna, Dipartimento Ingn Elettr, I-40136 Bologna, Italy
关键词
fault diagnosis; induction motor drives;
D O I
10.1109/28.871280
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, the impact of control on faulted induction machine behavior is presented. The diagnostic indexes usually used for open-loop operation are no longer effective. Simulation and experimental results show that the spectrum of the field current component i(d) in a field-oriented controlled machine has suitable features that can lead to an effective diagnostic procedure. Specifically,,in the case of stator and rotor faults the id spectrum components at frequencies 2f and 2sf, respectively, are quite independent of control parameters and dependent on the fault extent.
引用
收藏
页码:1318 / 1329
页数:12
相关论文
共 50 条
  • [1] Diagnosis of stator and rotor faults of an induction motor in closed-loop control structure
    Wolkiewicz, Marcin
    Tarchala, Grzegorz
    Orlowska-Kowalska, Teresa
    2018 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION (SPEEDAM), 2018, : 196 - 201
  • [2] The influence of closed loop control on the monitoring of induction motors faults
    Bouabid, Nourelhouda
    Moussa, Mohamed Amine
    Maouche, Yassine
    Khezzar, Abdelmalek
    2019 INTERNATIONAL CONFERENCE ON ADVANCED ELECTRICAL ENGINEERING (ICAEE), 2019,
  • [3] Diagnosis of Rotor Faults in Closed-Loop Induction Motor Drives
    Cruz, S. M. A.
    Cardoso, A. J. M.
    CONFERENCE RECORD OF THE 2006 IEEE INDUSTRY APPLICATIONS CONFERENCE, FORTY-FIRST IAS ANNUAL MEETING, VOL 1-5, 2006, : 2346 - 2353
  • [4] Detection of Broken Bars in Induction Motors Operating with Closed-Loop Speed Control
    Muzio, Francesca
    Mantione, Lorenzo
    Garcia-Calva, Tomas
    Frosini, Lucia
    Morinigo-Sotelo, Daniel
    MACHINES, 2024, 12 (09)
  • [5] Influence of Closed-Loop Control Operations on Detecting Induction Machine Stator Faults
    Meo, S.
    Ometto, A.
    Rotondale, N.
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2012, 7 (03): : 4359 - 4365
  • [6] CLOSED-LOOP PERFORMANCE OF INDUCTION-MOTORS WITH CONSTANT VOLTS-HERTZ CONTROL
    STEFANOVIC, VR
    ELECTRIC MACHINES AND ELECTROMECHANICS, 1977, 1 (03): : 255 - 266
  • [7] SIMPLE ALGORITHM FOR CLOSED-LOOP CONTROL OF STEPPING MOTORS
    GRIMBLEBY, JB
    IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 1995, 142 (01): : 5 - 13
  • [8] Impact of Closed-loop Control on Behavior of Inverter-fed Induction Motors with Rotor Broken-Bars Fault
    Abu-Elhaija, W.
    Ghorbanian, Vahid
    Faiz, Jawad
    Ebrahimi, Bashir
    IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, DRIVES AND ENERGY SYSTEMS (PEDES 2012), 2012,
  • [9] Detection of rotor eccentricity faults in closed-loop drive-connected induction motors using an artificial neural network
    Huang, XH
    Habetler, TG
    Harley, RG
    PESC 04: 2004 IEEE 35TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, CONFERENCE PROCEEDINGS, 2004, : 913 - 918
  • [10] An Advanced Closed-Loop Control to Improve the Performance of Hybrid Stepper Motors
    Le, Kien Minh
    Van Hoang, Hung
    Jeon, Jae Wook
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (09) : 7244 - 7255