Closed-loop control impact on the diagnosis of induction motors faults

被引:146
|
作者
Bellini, A [1 ]
Filippetti, F
Franceschini, G
Tassoni, C
机构
[1] Univ Parma, Dipartimento Ingn Informazione, I-43100 Parma, Italy
[2] Univ Bologna, Dipartimento Ingn Elettr, I-40136 Bologna, Italy
关键词
fault diagnosis; induction motor drives;
D O I
10.1109/28.871280
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, the impact of control on faulted induction machine behavior is presented. The diagnostic indexes usually used for open-loop operation are no longer effective. Simulation and experimental results show that the spectrum of the field current component i(d) in a field-oriented controlled machine has suitable features that can lead to an effective diagnostic procedure. Specifically,,in the case of stator and rotor faults the id spectrum components at frequencies 2f and 2sf, respectively, are quite independent of control parameters and dependent on the fault extent.
引用
收藏
页码:1318 / 1329
页数:12
相关论文
共 50 条
  • [21] Different procedures for the diagnosis of rotor fault in closed loop induction motors drives
    Bellini, A.
    Concari, C.
    Franceschini, G.
    Tassoni, C.
    IEEE IEMDC 2007: PROCEEDINGS OF THE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE, VOLS 1 AND 2, 2007, : 1427 - +
  • [22] ON CLOSED-LOOP OPTIMAL CONTROL
    SIDAR, M
    IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 1964, AC 9 (03) : 292 - &
  • [23] CLOSED-LOOP COMPUTER CONTROL
    GRAHAM, G
    INTECH, 1989, 36 (09) : 78 - 81
  • [24] Field Weakening Strategy Extended to Six-Step Operation for Dual Closed-Loop Current Control of Induction Motors
    Zhou, Zheng
    Li, Jian
    Lu, Yang
    Xu, Hongwei
    Zhang, Qinpei
    Wu, Linghao
    IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2025, 11 (01): : 2674 - 2683
  • [25] CLOSED-LOOP ENGINE CONTROL
    NIEPOTH, GW
    STONESTREET, SP
    IEEE SPECTRUM, 1977, 14 (11) : 52 - 55
  • [26] Closed-loop control with Oberon
    Hrebabetzky, F
    SOFTWARE-CONCEPTS AND TOOLS, 1997, 18 (02): : 73 - 79
  • [27] ON CLOSED-LOOP OPTIMAL CONTROL
    KLIGER, I
    IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 1965, AC10 (02) : 207 - &
  • [28] Closed-loop Stator Flux Control Method for Soft Starters to Prevent Rotor Speed oscillations in Induction Motors Drive
    Kim, Tae-Hoon
    Yang, Dae-Young
    Oh, Tae-Ho
    Kim, Young-Seok
    Lee, Sang-Hoon
    Cho, Dong-Il Dan
    2022 22ND INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS 2022), 2022, : 141 - 146
  • [29] Diagnosis of electrical damages of an induction motor supplied from a frequency converter in closed-loop control structure
    Wolkiewicz, Marcin
    Tarchala, Grzegorz
    PRZEGLAD ELEKTROTECHNICZNY, 2018, 94 (05): : 147 - 152
  • [30] SERVOPUMP POWERS 4 MOTORS IN A CLOSED-LOOP CIRCUIT
    BELL, GH
    BENDER, GF