Detection of Broken Bars in Induction Motors Operating with Closed-Loop Speed Control

被引:0
|
作者
Muzio, Francesca [1 ]
Mantione, Lorenzo [1 ]
Garcia-Calva, Tomas [2 ]
Frosini, Lucia [1 ]
Morinigo-Sotelo, Daniel [3 ]
机构
[1] Univ Pavia, Dept Elect Comp & Biomed Engn, I-27100 Pavia, Italy
[2] Univ Valladolid, HSPdigital Elect Engn Dept, Valladolid 47002, Spain
[3] Univ Valladolid, Inst Adv Prod Technol, Res Grp HSPdigital ADIRE, Valladolid 47002, Spain
关键词
induction motor; inverter; broken rotor bar; speed closed-loop control; fault detection; ROTOR FAULTS; DIAGNOSIS;
D O I
10.3390/machines12090662
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Rotor bar breakage in induction motors is often detected by analysing the signatures in the stator current. However, due to the alteration of the current spectrum, traditional methods may fail when inverter-fed motors operate with closed-loop control using a cascade structure to regulate the speed. In this paper, the potential of zero-sequence voltage analysis to detect this fault is investigated, and a new index to quantify the severity of the fault based on this signal is proposed. Signals from motors operating under different control strategies and signals from motors powered from the mains are considered to verify the robustness of the proposed fault severity index. As a result, in all the analysed conditions the value of the proposed index for the healthy motor is found to be approximately 0.010, while for the faulty machine it is between 0.110 and 0.252.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Impact of Closed-loop Control on Behavior of Inverter-fed Induction Motors with Rotor Broken-Bars Fault
    Abu-Elhaija, W.
    Ghorbanian, Vahid
    Faiz, Jawad
    Ebrahimi, Bashir
    [J]. IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, DRIVES AND ENERGY SYSTEMS (PEDES 2012), 2012,
  • [2] Quantitative broken rotor bar fault detection for closed-loop controlled induction motors
    Hou, Zhaowen
    Huang, Jin
    Liu, He
    Wang, Tong
    Zhao, Lihang
    [J]. IET ELECTRIC POWER APPLICATIONS, 2016, 10 (05) : 403 - 410
  • [3] NONINVASIVE DETECTION OF BROKEN ROTOR BARS IN OPERATING INDUCTION-MOTORS
    KLIMAN, GB
    KOEGL, RA
    STEIN, J
    ENDICOTT, RD
    MADDEN, MW
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 1988, 3 (04) : 873 - 879
  • [4] OPERATING SUBMERSIBLE PUMPS WITH CLOSED-LOOP SPEED CONTROL
    ALCOCK, DN
    [J]. OIL & GAS JOURNAL, 1981, 79 (41) : 115 - &
  • [5] Method for detection of broken bars in induction motors
    Dobrodeyev, PN
    Volokhov, SA
    Kildishev, AV
    Nyenhuis, JA
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 2000, 36 (05) : 3608 - 3610
  • [6] Closed-loop control impact on the diagnosis of induction motors faults
    Bellini, A
    Filippetti, F
    Franceschini, G
    Tassoni, C
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2000, 36 (05) : 1318 - 1329
  • [7] OPERATING SUBMERSIBLE PUMPS WITH CLOSED-LOOP SPEED CONTROL.
    Alcock, Derrick
    [J]. Oil and Gas Journal, 1981, 79 (41): : 115 - 128
  • [8] Detection of Broken Bars on Induction Motors using MODWT
    Lopez-Hernandez, Monica
    Rangel-Magdaleno, Jose
    Peregrina-Barreto, Hayde
    Ramirez-Cortes, Juan
    [J]. 2018 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC): DISCOVERING NEW HORIZONS IN INSTRUMENTATION AND MEASUREMENT, 2018, : 1068 - 1072
  • [9] Closed-loop Stator Flux Control Method for Soft Starters to Prevent Rotor Speed oscillations in Induction Motors Drive
    Kim, Tae-Hoon
    Yang, Dae-Young
    Oh, Tae-Ho
    Kim, Young-Seok
    Lee, Sang-Hoon
    Cho, Dong-Il Dan
    [J]. 2022 22ND INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS 2022), 2022, : 141 - 146
  • [10] MINOR CLOSED-LOOP CONTROL OF STEPPING MOTORS FOR USE IN HIGH-SPEED POSITIONING
    VRAETS, JW
    FRENCH, D