Detection of Broken Bars in Induction Motors Operating with Closed-Loop Speed Control

被引:0
|
作者
Muzio, Francesca [1 ]
Mantione, Lorenzo [1 ]
Garcia-Calva, Tomas [2 ]
Frosini, Lucia [1 ]
Morinigo-Sotelo, Daniel [3 ]
机构
[1] Univ Pavia, Dept Elect Comp & Biomed Engn, I-27100 Pavia, Italy
[2] Univ Valladolid, HSPdigital Elect Engn Dept, Valladolid 47002, Spain
[3] Univ Valladolid, Inst Adv Prod Technol, Res Grp HSPdigital ADIRE, Valladolid 47002, Spain
关键词
induction motor; inverter; broken rotor bar; speed closed-loop control; fault detection; ROTOR FAULTS; DIAGNOSIS;
D O I
10.3390/machines12090662
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Rotor bar breakage in induction motors is often detected by analysing the signatures in the stator current. However, due to the alteration of the current spectrum, traditional methods may fail when inverter-fed motors operate with closed-loop control using a cascade structure to regulate the speed. In this paper, the potential of zero-sequence voltage analysis to detect this fault is investigated, and a new index to quantify the severity of the fault based on this signal is proposed. Signals from motors operating under different control strategies and signals from motors powered from the mains are considered to verify the robustness of the proposed fault severity index. As a result, in all the analysed conditions the value of the proposed index for the healthy motor is found to be approximately 0.010, while for the faulty machine it is between 0.110 and 0.252.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] A Novel Algorithm to Detect Broken Bars in Induction Motors
    Souza, Mateus Ventura
    Lima, Jose Claudeni Oliveira
    Roque, Alexandre Magno Pinto
    Riffel, Douglas Bressan
    [J]. MACHINES, 2021, 9 (11)
  • [32] A Strategy for Broken Bars Diagnosis in Induction Motors Drives
    Otero, M.
    de la Barrera, P. M.
    Bossio, G. R.
    Leidhold, R.
    [J]. IEEE LATIN AMERICA TRANSACTIONS, 2018, 16 (02) : 322 - 328
  • [33] Broken Rotor Bars Detection in Inverter-Fed Induction Motors Under Continuous Switching of Different Speed Modes
    Wang, Panpan
    Wang, Kaixuan
    Chen, Lizheng
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2024, 71 (01) : 975 - 984
  • [34] Speed Adaptive Voltage Closed-Loop Field-Weakening Control for Induction Motor Drives
    Wang, Bo
    Zhang, Jing
    Yu, Yong
    Zhang, Xu
    Xu, Dianguo
    [J]. 2019 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2019, : 7078 - 7083
  • [35] Closed-Loop Scalar Speed Control of Induction Motor Drive with Limited Regenerative Braking Ability
    Cohen, Guy
    Sassonker, Moria
    Kuperman, Alon
    [J]. 2021 IEEE 19TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (PEMC), 2021, : 757 - 760
  • [36] The influence of closed loop control on the monitoring of induction motors faults
    Bouabid, Nourelhouda
    Moussa, Mohamed Amine
    Maouche, Yassine
    Khezzar, Abdelmalek
    [J]. 2019 INTERNATIONAL CONFERENCE ON ADVANCED ELECTRICAL ENGINEERING (ICAEE), 2019,
  • [37] 3-DOF closed-loop control for planar linear motors
    Quaid, AE
    Hollis, RL
    [J]. 1998 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-4, 1998, : 2488 - 2493
  • [38] An Advanced Closed-Loop Control to Improve the Performance of Hybrid Stepper Motors
    Le, Kien Minh
    Van Hoang, Hung
    Jeon, Jae Wook
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (09) : 7244 - 7255
  • [39] Closed-Loop MRAS Speed Observer for Linear Induction Motor Drives
    Accetta, Angelo
    Cirrincione, Maurizio
    Pucci, Marcello
    Vitale, Gianpaolo
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2015, 51 (03) : 2279 - 2290
  • [40] Closed-Loop MRAS Speed Observer for Linear Induction Motor Drives
    Accetta, Angelo
    Cirrincione, Maurizio
    Pucci, Marcello
    Vitale, Gianpaolo
    [J]. 2013 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2013, : 3821 - 3829