Stability changes of dental implants according to the simulated peri-implant bone defects

被引:0
|
作者
Park, Chan-Jin [1 ]
Lee, Mi-Ran [1 ]
Cho, Lee-Ra [1 ]
Yi, Yang-Jin [1 ]
Jung, Ho-Nyun [2 ]
机构
[1] Kangnung Natl Univ, Coll Dent, Dept Prosthodont, Jibyun-dong 123, Kangnung, South Korea
[2] Korea Food & Drug Adm, Seoul 122704, South Korea
来源
ASBM7: ADVANCED BIOMATERIALS VII | 2007年 / 342-343卷
关键词
dental implant; gray values; radiography; resonance frequency analysis;
D O I
10.4028/www.scientific.net/KEM.342-343.57
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Twenty implants of 3.75mm in diameter(Neoplant, Neobiotech, Korea) were used to evaluate the correlation between the resonance frequency analysis (RFA) and the radiographic method for perimplant bone change under in vitro conditions. To simulate peri-implant bone change, 2mm-deep 45 degrees range horizontal defect and 2mm-deep 90 degrees range horizontal defect area were serially prepared perpendicular to the X-ray beam after conventional implant insertion. ISQ values and gray values inside threads were measured before and after peri-implant bone defect preparation. ISQ value of resonance frequency analysis was changed according to peri-implant bone (hange and gray value of radiographic method was changed according to peri-implant bone change. In horizontal defect condition, relatively positive correlation were between ISQ and gray values r=0.663).
引用
收藏
页码:57 / +
页数:2
相关论文
共 50 条
  • [21] Evaluation of the peri-implant bone trabecular microstructure changes in short implants with fractal analysis
    Hatice Cansu Kış
    Ayşegül Güleryüz Gürbulak
    International Journal of Implant Dentistry, 6
  • [22] Endodontic peri-implant defects
    Wadia R.
    British Dental Journal, 2020, 228 (4) : 253 - 253
  • [24] Peri-Implant Behavior of Tissue Level Dental Implants with a Convergent Neck
    Agustin-Panadero, Ruben
    Bermudez-Mulet, Irene
    Fernandez-Estevan, Lucia
    Fernanda Sola-Ruiz, Maria
    Marco-Pitarch, Rocio
    Garcia-Selva, Marina
    Zubizarreta-Macho, Alvaro
    Leon-Martinez, Raquel
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (10)
  • [25] Detection of peri-implant bone changes with axial tomosynthesis
    Horton, RA
    Ludlow, JB
    Webber, RL
    Gates, W
    Nason, RH
    Reboussin, D
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1996, 81 (01): : 124 - 129
  • [26] Comparative evaluation of the peri-implant bone tissue mineral density around unloaded titanium dental implants
    Traini, Tonino
    Degidi, Marco
    Iezzi, Giovanna
    Artese, Luciano
    Piattelli, Adriano
    JOURNAL OF DENTISTRY, 2007, 35 (01) : 84 - 92
  • [27] Levels of glycosaminoglycans in peri-implant sulcus fluid as a means of monitoring bone response to endosseous dental implants
    Beck, C. B.
    Embery, G.
    Langley, M. S.
    Waddington, R. J.
    CLINICAL ORAL IMPLANTS RESEARCH, 1991, 2 (04) : 179 - 185
  • [28] Effect of surgical techniques on primary implant stability and peri-implant bone
    Fanuscu, Mete I.
    Chang, Ting-Ling
    Akca, Kivanc
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2007, 65 (12) : 2487 - 2491
  • [29] Immediately loaded mini dental implants as overdenture retainers: 1-Year cohort study of implant stability and peri-implant marginal bone level
    Scepanovic, Miodrag
    Todorovic, Aleksandar
    Markovic, Aleksa
    Patrnogic, Vesna
    Milicic, Biljana
    Moufti, Adel M.
    Misic, Tijana
    ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2015, 199 : 85 - 91
  • [30] Peri-implant Crestal Bone Changes Around Zirconia Implants in Periodontally Healthy and Compromised Patients
    Kniha, Kristian
    Milz, Stefan
    Kniha, Heinz
    Ayoub, Nassim
    Hoelzle, Frank
    Modabber, Ali
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (01) : 217 - 222