Effect of surgical techniques on primary implant stability and peri-implant bone

被引:50
|
作者
Fanuscu, Mete I.
Chang, Ting-Ling
Akca, Kivanc
机构
[1] Univ Calif Los Angeles, Sch Dent, Jane & Jerry Weintraub Ctr Reconstruct Biotechnol, Los Angeles, CA USA
[2] Univ Calif Los Angeles, Sch Dent, Jane & Jerry Weintraub Ctr Reconstruct Biotechnol, Div Adv Prosthodont, Los Angeles, CA USA
[3] Univ Calif Los Angeles, Sch Dent, Jane & Jerry Weintraub Ctr Reconstruct Biotechnol, Div Restorat Dent, Los Angeles, CA USA
[4] Hacettepe Univ, Fac Dent, Dept Prosthodont, TR-06100 Ankara, Turkey
关键词
D O I
10.1016/j.joms.2007.04.017
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the primary stability of dental implants placed with condensing-osteotome versus drilling-osteotome techniques and to explore peri-implant mircromorphologic consequences of lateral bone condensing. Materials and Methods: The experimental model designed for the study comprised bilateral iliac crests from 3 fresh frozen human cadavers. Two AstraTech dental implants (AstraTech AB, Molndal, Sweden) were consecutively placed with condensing- and drilling-osteotome techniques in bone with a 10-mm interimplant distance. Six experimental bone sites received a total of 12 implants. Installation torque values (ITVs) and implant stability quotients (ISQs) were measured to quantify primary implant stability. Bone specimens including implants were removed to quantify the peri-implant relative bone volume and bone microstructural parameters in the I-mm circular vicinity of implants using desktop computed tomography (microCT). The Mann-Whitney U test was used to evaluate the differences in primary implant stability values and microCT data for the surgical placement techniques. Results: ITVs and ISQs were similar for both surgical placement techniques without statistical significance (P > .05). Relative bone volumes around implants placed with the condensing-osteotome technique were significantly (P < .05) higher than those around implants placed with the drilling-osteotome technique. Microstructural parameters, such as trabecular thickness, separation, and number, differed significantly between the 2 osteotome techniques. Conclusions: managing implant sites with the condensing-osteotome technique results in notable changes in peri-implant bone architecture but might not be as promising in improving primary implant stability compared with the drilling-osteotome technique. (c) 2007 American Association of Oral and Maxillofacial Surgeons.
引用
收藏
页码:2487 / 2491
页数:5
相关论文
共 50 条
  • [1] Influence of peri-implant bone quality on implant stability
    Schiuma, Damiano
    Plecko, Michael
    Kloub, Martin
    Rothstock, Stephan
    Windolf, Markus
    Gueorguiev, Boyko
    [J]. MEDICAL ENGINEERING & PHYSICS, 2013, 35 (01) : 82 - 87
  • [2] Effect of Implant Surface Properties on Peri-Implant Bone Healing: Implant Stability and Microcomputed Tomographic Analysis
    Al-Moaber, Samar H.
    Al-Hamdan, Khalid
    Junker, Rudiger
    Jansen, John A.
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (01) : 77 - 83
  • [3] Effect of implant surface roughness and loading on peri-implant bone formation
    Vandamme, Katleen
    Naert, Ignace
    Sloten, Jozef Vander
    Puers, Robert
    Duyck, Joke
    [J]. JOURNAL OF PERIODONTOLOGY, 2008, 79 (01) : 150 - 157
  • [4] Impact of implant overloading on the peri-implant bone in inflamed and non-inflamed peri-implant mucosa
    Kozlovsky, Avital
    Tal, Haim
    Laufer, Ben-Zion
    Leshem, Roy
    Rohrer, Michael D.
    Weinreb, Miron
    Artzi, Zvi
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2007, 18 (05) : 601 - 610
  • [5] Augmentation of peri-implant bone improves implant stability: Quantification using simulated bone loss
    Wirth, Andreas J.
    Mueller, Ralph
    van Lenthe, G. Harry
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2012, 30 (02) : 178 - 184
  • [6] Correlation between peri-implant bone mineral density and primary implant stability based on artificial intelligence classification
    Xiao, Yanjun
    Lv, Lingfeng
    Xu, Zonghe
    Zhou, Lin
    Lin, Yanjun
    Lin, Yue
    Guo, Jianbin
    Chen, Jiang
    Ou, Yanjing
    Lin, Lin
    Wu, Dong
    [J]. SCIENTIFIC REPORTS, 2024, 14 (01):
  • [7] On the material dependency of peri-implant morphology and stability in healing bone
    Bruns, Stefan
    Krueger, Diana
    Galli, Silvia
    Wieland, D. C. Florian
    Hammel, Jorg U.
    Beckmann, Felix
    Wennerberg, Ann
    Willumeit-Roemer, Regine
    Zeller-Plumhoff, Berit
    Moosmann, Julian
    [J]. BIOACTIVE MATERIALS, 2023, 28 : 155 - 166
  • [8] Effect of bone quality, implant design, and surgical technique on primary implant stability
    Karl, Matthias
    Grobecker-Karl, Tanja
    [J]. QUINTESSENCE INTERNATIONAL, 2018, 49 (03): : 189 - 198
  • [9] Primary stability of implants with peri-implant bone defects of various widths: an in vitro investigation
    Yim, Hyun-Jin
    Lim, Hyun-Chang
    Hong, Ji-Youn
    Shin, Seung-Il
    Chung, Jong-Hyuk
    Herr, Yeek
    Shin, Seung-Yun
    [J]. JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2019, 49 (01): : 39 - 46
  • [10] Influence of forces on peri-implant bone
    Isidor, Flemming
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 : 8 - 18