Immediately loaded mini dental implants as overdenture retainers: 1-Year cohort study of implant stability and peri-implant marginal bone level

被引:22
|
作者
Scepanovic, Miodrag [1 ]
Todorovic, Aleksandar [1 ]
Markovic, Aleksa [2 ]
Patrnogic, Vesna [1 ]
Milicic, Biljana [3 ]
Moufti, Adel M. [4 ]
Misic, Tijana [2 ]
机构
[1] Univ Belgrade, Fac Med Dent, Dept Prosthodont, Belgrade 11000, Serbia
[2] Univ Belgrade, Fac Med Dent, Dept Oral Surg, Belgrade 11000, Serbia
[3] Univ Belgrade, Dept Med Stat & Informat, Belgrade 11000, Serbia
[4] Univ Manchester, Dept Restorat Dent, Manchester M15 6FH, Lancs, England
关键词
Mini dental implants; Immediate loading; Implant stability; Periotest (R); Peri-implant marginal bone level; MANDIBULAR OVERDENTURES; ITI-IMPLANTS; ENDOSSEOUS IMPLANTS; SUCCESS; CRITERIA; TORQUE; TRIAL;
D O I
10.1016/j.aanat.2013.12.005
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
Aim: This 1-year cohort study investigated stability and pen-implant marginal bone level of immediately loaded mini dental implants used to retain overdentures. Materials and methods: Each of 30 edentulous patients received 4 mini dental implants (1.8 mm x 13 mm) in the interforaminal mandibular region. The implants were immediately loaded with pre-made overdentures. Outcome measures included implant stability and bone resorption. Implant stability was measured using the Periotest Classic (R) device immediately after placement and on the 3rd and 6th weeks and the 4th, 6th and 12th months postoperatively. The pen-implant marginal bone level (PIBL) was evaluated at the implant's mesial and distal sides from the polished platform to the marginal crest. Radiographs were taken using a tailored film holder to reproducibly position the X-ray tube at the 6th week, 4th and 12th months postoperatively. Results: The primary stability (Periotest value, PTV) measured -0.27 +/- 3.41 on a scale of -8 to + 50 (lower PTV reflects higher stability). The secondary stability decreased significantly until week 6 (mean PTV = 7.61 +/- 7.05) then increased significantly reaching (PTV = 6.17 +/- 6.15) at 12 months. The mean PIBL measured 0.40 mm after 1 year of functional loading, with no statistically significant differences at the various follow-ups (p = 0.218). Conclusions: Mini dental implants placed into the interforaminal region could achieve a favorable primary stability for immediate loading. The follow-up Periotest values fluctuated, apparently reflecting the dynamics of bone remodeling, with the implants remaining clinically stable (98.3%) after 1 year of function. The 1-year bone resorption around immediately loaded MDIs is within the clinically acceptable range for standard implants. (C) 2014 Elsevier GmbH. All rights reserved.
引用
收藏
页码:85 / 91
页数:7
相关论文
共 50 条
  • [1] Osteocyte Density in the Peri-Implant Bone of Immediately Loaded and Submerged Dental Implants
    Barros, Raquel R. M.
    Degidi, Marco
    Novaes, Arthur B., Jr.
    Piattelli, Adriano
    Shibli, Jamil A.
    Iezzi, Giovanna
    [J]. JOURNAL OF PERIODONTOLOGY, 2009, 80 (03) : 499 - 504
  • [2] Peri-implant bone reactions at delayed and immediately loaded implants: an experimental study
    Kim, Se-Hoon
    Choi, Byung-Ho
    Li, Jingxu
    Kim, Han-Sung
    Ko, Chang-Yong
    Jeong, Seung-Mi
    Xuan, Feng
    Lee, Seoung-Ho
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2008, 105 (02): : 144 - 148
  • [3] Peri-implant bone reactions to immediately loaded implants. An experimental study in monkeys
    Romanos, G
    Toh, CG
    Siar, CH
    Swaminathan, D
    Ong, AH
    Donath, K
    Yaacob, H
    Nentwig, GH
    [J]. JOURNAL OF PERIODONTOLOGY, 2001, 72 (04) : 506 - 511
  • [4] Peri-implant tissue response of immediately loaded, threaded, HA-coated implants: 1-year results
    Rungcharassaeng, K
    Lozada, JL
    Kan, JYK
    Kim, JS
    Campagni, WV
    Munoz, CA
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2002, 87 (02): : 173 - 181
  • [5] Collagen fiber orientation in human peri-implant bone around immediately loaded and unloaded titanium dental implants
    Traini, T
    Degidi, M
    Caputi, S
    Strocchi, R
    Di Iorio, D
    Piattelli, A
    [J]. JOURNAL OF PERIODONTOLOGY, 2005, 76 (01) : 83 - 89
  • [6] Stability changes of dental implants according to the simulated peri-implant bone defects
    Park, Chan-Jin
    Lee, Mi-Ran
    Cho, Lee-Ra
    Yi, Yang-Jin
    Jung, Ho-Nyun
    [J]. ASBM7: ADVANCED BIOMATERIALS VII, 2007, 342-343 : 57 - +
  • [7] Peri-implant inflammation and marginal bone level changes around dental implants in relation to proximity with and bone level of adjacent teeth
    Ng, K. T.
    Fan, M. H. M.
    Leung, M. C.
    Fokas, G.
    Mattheos, N.
    [J]. AUSTRALIAN DENTAL JOURNAL, 2018, 63 (04) : 467 - 477
  • [8] Histologic and Histomorphometric Analyses of Peri-implant Bone from Loaded Dental Implants: A Case Report
    Chiou, Lan-Lin
    Tanaka, Yoshiatsu
    Iwanaga, Joe
    Tubbs, R. Shane
    Blanchard, Steven
    Hamada, Yusuke
    [J]. INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2023, 43 (03) : 371 - 377
  • [9] Cement-associated peri-implant mucositis. A 1-year follow-up after excess cement removal on the peri-implant tissue of dental implants
    Korsch, Michael
    Walther, Winfried
    Bartols, Andreas
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2017, 19 (03) : 523 - 529
  • [10] Biological complications and peri-implant clinical and radiographic changes at immediately placed dental implants. A prospective 5-year cohort study
    Rodrigo, Daniel
    Martin, Conchita
    Sanz, Mariano
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (10) : 1224 - 1231