Second harmonic imaging:: a new ultrasound technique to assess human brain tumour perfusion

被引:43
|
作者
Harrer, JU [1 ]
Mayfrank, L [1 ]
Mull, M [1 ]
Klötzsch, C [1 ]
机构
[1] Univ Hosp Aachen, Dept Neurol, D-52074 Aachen, Germany
来源
关键词
D O I
10.1136/jnnp.74.3.333
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Second harmonic imaging is a new ultrasound technique that allows evaluation of brain tissue perfusion after application of an ultrasound contrast agent. Objective: To evaluate the potential of this technique for the assessment of abnormal echo contrast characteristics of different brain tumours. Methods: 27 patients with brain tumours were studied. These were divided into four groups: gliomas, WHO grade III-IV (n = 6); meningiomas (n = 9); metastases (n = 5); and others (n = 7). Patients were examined by second harmonic imaging in a transverse axial insonation plane using the transtemporal approach. Following intravenous administration of 4 g (400 mg/ml) of a galactose based echo contrast agent, 62 time triggered images (one image per 2.5 seconds) were recorded and analysed offline. Time-intensity curves of two regions of interest (tumour tissue and healthy brain tissue), including peak intensity (PI) (dB), time to peak intensity (TP) (s), and positive gradient (PG) (dB/s), as well as ratios of the peak intensities of the two regions of interest, were derived from the data and compared intraindividually and interindividually. Results: After administration of the contrast agent a marked enhancement of echo contrast was visible in the tumour tissue in all patients. Mean PI and PG were significantly higher in tumour tissue than in healthy brain parenchyma (11.8 v 5.1 dB and 0.69 v 0.16 dB/s; p < 0.001). TP did not differ significantly (37.1 v 50.2 s; p = 0. 14). A tendency towards higher PI and PG as well as shorter TP was apparent in malignant gliomas. When comparing different tumour types, however, none of these variables reached significance, nor were there significant differences between malignant and benign tumours in general. Conclusions: Second harmonic imaging not only allows identification of brain tumours, but may also help in distinguishing between different tumour types. It gives additional and alternative information about tumour perfusion. Further studies are needed to evaluate the clinical potential of this technique in investigating brain tumours-for example in follow up investigations of patients undergoing radiation or chemotherapy-especially in comparison with neuroradiological and neuropathological findings.
引用
收藏
页码:333 / 338
页数:6
相关论文
共 50 条
  • [21] Arrival time parametric imaging: A new ultrasound technique for quantifying perfusion of kidney grafts
    Fischer, T.
    Fillmonow, S.
    Rudolph, J.
    Morgera, S.
    Budde, K.
    Slowinski, T.
    Ebeling, V.
    Taymoorian, K.
    Giessing, M.
    Thomas, A.
    ULTRASCHALL IN DER MEDIZIN, 2008, 29 (04): : 418 - 423
  • [22] Tissue Second Harmonic Ultrasound Imaging Using Huffman Sequence
    Mardi, Zahra
    Mahloojifar, Ali
    2016 23RD IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING AND 2016 1ST INTERNATIONAL IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING (ICBME), 2016, : 177 - 181
  • [23] Comparison of pulse inversion and second harmonic for ultrasound contrast imaging
    Kirkhorn, J
    Frigstad, S
    Torp, H
    2000 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2000, : 1897 - 1901
  • [24] New Details of the Human Corneal Limbus Revealed With Second Harmonic Generation Imaging
    Park, Choul Yong
    Lee, Jimmy K.
    Zhang, Cheng
    Chuck, Roy S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (10) : 6058 - 6066
  • [25] Quantitative myocardial perfusion studies:: Comparison of pulse inversion technique, harmonic power Doppler and second harmonic imaging with simultaneous technetium SPECT studies
    von Bibra, H
    Niklasson, U
    Bone, D
    Fröman, M
    Larsen, F
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 413A - 413A
  • [26] Visualization of perfusion imaging using ultrasound contrast agent and harmonic ultrasound in rabbit eyes.
    Hirokawa, T
    Hayashi, M
    Murata, H
    Takebayashi, M
    Fuke, K
    Ohki, T
    Kajima, M
    Naito, T
    Yamane, S
    Shiota, H
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S415 - S415
  • [27] Confirmation of brain death using brain radionuclide perfusion imaging technique
    Al-Shammri, S
    Al-Feeli, M
    MEDICAL PRINCIPLES AND PRACTICE, 2004, 13 (05) : 267 - 272
  • [28] Quantification of Macrocirculation and Microcirculation in Brain Using Ultrasound Perfusion Imaging
    Vinke, Eline J.
    Eyding, Jens
    de Korte, Chris
    Slump, Cornelis H.
    van der Hoeven, Johannes G.
    Hoedemaekers, Cornelia W. E.
    INTRACRANIAL PRESSURE & NEUROMONITORING XVI, 2018, 126 : 115 - 120
  • [29] Harmonic grey scale imaging of the human brain
    Seidel, G
    Greis, C
    Sonne, J
    Kaps, M
    JOURNAL OF NEUROIMAGING, 1999, 9 (03) : 171 - 174
  • [30] Sonographic harmonic grey scale imaging of brain perfusion:: Scope of a new method demonstrated in selected cases
    Stolz, E
    Allendörfer, J
    Jauss, M
    Traupe, H
    Kaps, M
    ULTRASCHALL IN DER MEDIZIN, 2002, 23 (05): : 320 - 324