Harmonic grey scale imaging of the human brain

被引:46
|
作者
Seidel, G
Greis, C
Sonne, J
Kaps, M
机构
[1] Univ Lubeck, Dept Neurol, D-23538 Lubeck, Germany
[2] Bracco Byk Gulden, Constance, Germany
关键词
ultrasonics; contrast media; harmonic imaging; brain perfusion;
D O I
10.1111/jon199993171
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Harmonic imaging increases the signal-to-noise ratio in grey-scale imaging. With the use of ultrasound contrast agents (UCA), imaging of brain perfusion seems possible. The authors used an ultrasound system in connection with a 1.8/3.6-MHz harmonic sector transducer and an acoustic densitometry unit for quantification of ultrasound intensity in the thalamus (THAL), the temporoparietal white matter (TPWM), and the lateral fissure (LF). Ten milliliters of BY963, a spherosome-air-based UCA, was injected intravenously in 12 healthy volunteers. Time-intensity curves were calculated. Mean increase of intensity (standard deviation [SD]), mean area under the time-intensity curve (AUC) from baseline (SD), and mean transit time (MTT) (SD) in the region of LF, THAL, and TPWM were 2.2 +/- 1.7, 1.1 +/- 0.6, 0.9 +/- 0.9 dB and 16.7 +/- 22.7, 4.7 +/- 4.7, 3.7 +/- 6.3 as well as 11.1 +/- 3.5, 9.7 +/- 3.1, and 11.9 +/- 8.0, respectively. There was a statistically significant difference for mean AUC (p = 0.02) but none comparing mean intensity increase (p = 0.07) and MTT (p = 0.9). The authors' study indicates that different regions of the human brain show different time-intensity curves. These results suggest that it is possible to measure parameters closely related to perfusion in various regions of the adult human brain.
引用
收藏
页码:171 / 174
页数:4
相关论文
共 50 条
  • [1] Sonographic harmonic grey scale imaging of brain perfusion:: Scope of a new method demonstrated in selected cases
    Stolz, E
    Allendörfer, J
    Jauss, M
    Traupe, H
    Kaps, M
    ULTRASCHALL IN DER MEDIZIN, 2002, 23 (05): : 320 - 324
  • [2] Perfusion harmonic imaging of the human brain
    Metzler, V
    Seidel, G
    Wiesmann, M
    Meyer, K
    Aach, T
    MEDICAL IMAGING 2003: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2003, 5035 : 337 - 348
  • [3] Volumetric imaging of grey and white matter in the human brain
    Buch, S.
    Ye, Y.
    McDonald, S.
    Haacke, E. M.
    MULTIPLE SCLEROSIS JOURNAL, 2014, 20 : 273 - 273
  • [4] Harmonic imaging of the human brain - Visualization of brain perfusion with ultrasound
    Seidel, G
    Algermissen, C
    Christoph, A
    Claassen, L
    Vidal-Langwasser, M
    Katzer, T
    STROKE, 2000, 31 (01) : 151 - 154
  • [5] GREY SCALE IMAGING IN SONAR
    DONALD, I
    SCOTTISH MEDICAL JOURNAL, 1975, 20 (04) : 177 - 179
  • [6] Doppler energy, second harmonic and standard grey scale imaging in myocardial contrast echocardiography - A comparative animal study
    vonBibra, H
    Horcher, J
    Erhardt, W
    Tuchnitz, A
    Blobner, M
    JungGottfert, S
    CIRCULATION, 1996, 94 (08) : 2624 - 2624
  • [7] Simulation of Grey Scale Ghost Imaging By Labview
    DING JianZHAO ShengmeiInstitute of Signal Processing and TransmissionNanjing University of Posts and TelecommunicationsNanjing China
    南京邮电大学学报(自然科学版), 2011, 31 (02) : 94 - 99
  • [8] Quality assurance for grey-scale imaging
    Madsen, EL
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 : S48 - S50
  • [9] Third Harmonic Generation Microscopy for Label-free Human Brain Imaging
    Chakraborty, Sandeep
    Gao, Hao-Cheng
    Yen, Chen-Tung
    Huang, Hsin-Yi
    Sun, Chi-Kuang
    2018 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2018,
  • [10] Quantification of flow rates using harmonic grey-scale imaging and an ultrasound contrast agent:: an in vitro and in vivo study
    Claassen, L
    Seidel, G
    Algermissen, C
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (01): : 83 - 88