Second harmonic imaging:: a new ultrasound technique to assess human brain tumour perfusion

被引:43
|
作者
Harrer, JU [1 ]
Mayfrank, L [1 ]
Mull, M [1 ]
Klötzsch, C [1 ]
机构
[1] Univ Hosp Aachen, Dept Neurol, D-52074 Aachen, Germany
来源
关键词
D O I
10.1136/jnnp.74.3.333
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Second harmonic imaging is a new ultrasound technique that allows evaluation of brain tissue perfusion after application of an ultrasound contrast agent. Objective: To evaluate the potential of this technique for the assessment of abnormal echo contrast characteristics of different brain tumours. Methods: 27 patients with brain tumours were studied. These were divided into four groups: gliomas, WHO grade III-IV (n = 6); meningiomas (n = 9); metastases (n = 5); and others (n = 7). Patients were examined by second harmonic imaging in a transverse axial insonation plane using the transtemporal approach. Following intravenous administration of 4 g (400 mg/ml) of a galactose based echo contrast agent, 62 time triggered images (one image per 2.5 seconds) were recorded and analysed offline. Time-intensity curves of two regions of interest (tumour tissue and healthy brain tissue), including peak intensity (PI) (dB), time to peak intensity (TP) (s), and positive gradient (PG) (dB/s), as well as ratios of the peak intensities of the two regions of interest, were derived from the data and compared intraindividually and interindividually. Results: After administration of the contrast agent a marked enhancement of echo contrast was visible in the tumour tissue in all patients. Mean PI and PG were significantly higher in tumour tissue than in healthy brain parenchyma (11.8 v 5.1 dB and 0.69 v 0.16 dB/s; p < 0.001). TP did not differ significantly (37.1 v 50.2 s; p = 0. 14). A tendency towards higher PI and PG as well as shorter TP was apparent in malignant gliomas. When comparing different tumour types, however, none of these variables reached significance, nor were there significant differences between malignant and benign tumours in general. Conclusions: Second harmonic imaging not only allows identification of brain tumours, but may also help in distinguishing between different tumour types. It gives additional and alternative information about tumour perfusion. Further studies are needed to evaluate the clinical potential of this technique in investigating brain tumours-for example in follow up investigations of patients undergoing radiation or chemotherapy-especially in comparison with neuroradiological and neuropathological findings.
引用
收藏
页码:333 / 338
页数:6
相关论文
共 50 条
  • [41] Third and second harmonic generation imaging of human articular cartilage
    Tsai, Ming-Rung
    Chen, Chih-Hwa
    Sun, Chi-Kuang
    MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES IX, 2009, 7183
  • [42] RENAL DOPPLER ULTRASOUND: A NEW TOOL TO ASSESS RENAL PERFUSION IN CRITICAL ILLNESS
    Le Dorze, Matthieu
    Bougle, Adrien
    Deruddre, Stephane
    Duranteau, Jacques
    SHOCK, 2012, 37 (04): : 360 - 365
  • [43] Super harmonic imaging: A new imaging technique for improved contrast detection
    Bouakaz, A
    Frigstad, S
    Ten Cate, FJ
    de Jong, N
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (01): : 59 - 68
  • [44] New mode of domain imaging: Second harmonic generation microscopy
    Kirilyuk, V
    Kirilyuk, A
    Rasing, T
    JOURNAL OF APPLIED PHYSICS, 1997, 81 (08) : 5014 - 5014
  • [45] A novel perfusion imaging technique of the pancreas: contrast-enhanced harmonic EUS (with video)
    Kitano, Masayuki
    Sakamoto, Hiroki
    Matsui, Uwe
    Ito, Yasuhiro
    Maekawa, Kiyoshi
    von Schrenck, Tammo
    Kudo, Masatoshi
    GASTROINTESTINAL ENDOSCOPY, 2008, 67 (01) : 141 - 150
  • [46] An Efficient and Multi-Focal Focused Ultrasound Technique for Harmonic Motion Imaging
    Saharkhiz, Niloufar
    Kamimura, Hermes A. S.
    Konofagou, Elisa E.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2023, 70 (04) : 1150 - 1161
  • [47] Role of diffusion- and perfusion-weighted MR imaging for brain tumour characterisation
    Rizzo, L.
    Crasto, S. Greco
    Moruno, P. Garcia
    Cassoni, P.
    Ruda, R.
    Boccaletti, R.
    Brosio, M.
    De Lucchi, R.
    Fava, C.
    RADIOLOGIA MEDICA, 2009, 114 (04): : 645 - 659
  • [48] Noninvasive pH imaging in human brain tumour at 1.5 Tesla
    Dai, Z. Z.
    Wei, M. B.
    Shen, Z. W.
    Xiao, G.
    Wu, R. H.
    JOURNAL OF NEUROLOGY, 2012, 259 : S214 - S214
  • [49] Endoscopic laser imaging of tissue perfusion: New instrumentation and technique
    Forrester, KR
    Stewart, C
    Leonard, C
    Tulip, J
    Bray, RC
    LASERS IN SURGERY AND MEDICINE, 2003, 33 (03) : 151 - 157
  • [50] Increased echocardiographic contrast brightness with higher ultrasound power during second harmonic imaging
    Pellikka, PA
    Foley, DA
    Klarich, KW
    Mulvagh, SL
    CIRCULATION, 1997, 96 (08) : 2554 - 2554