Continuous flow 2H/1H and and18O/16O analysis of water samples with dual inlet precision

被引:223
|
作者
Gehre, M
Geilmann, H
Richter, J
Werner, RA
Brand, WA
机构
[1] Max Planck Inst Biogeochem, D-07701 Jena, Germany
[2] UFZ Helmholtz Ctr Environm Res, D-04318 Leipzig, Germany
关键词
D O I
10.1002/rcm.1672
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method for isotope ratio analysis of water samples is described comprising an on-line high-temperature reduction technique in a helium carrier gas. Using a gas-tight syringe, injection of 0.5 to 1 muL sample is made through a heated septum into a glassy carbon reactor at temperatures in excess of 1300degreesC. More than 150 injections can be made per day and both isotope ratios of interest delta(2)H and 6180, can be measured with the same setup. The technique has the capability to transfer high-precision stable isotope ratio analysis of water samples from a specialized to a routine laboratory task compatible with other common techniques (automated injection for GC, LC, etc.). Experiments with an emphasis on the reactor design were made in two different laboratories using two different commercially available high-temperature elemental analyser (EA) systems. In the Jena TC/EA unit, sample-to-sample memory (single injection) has been reduced to similar to1% and high precision of about 0.1parts per thousand for delta(18)O and <1parts per thousand for delta(2)H has been achieved by a redesign of the glassy carbon reactor and by redirecting the gas flow of the commercial TC/EA unit. With the modified reactor, the contact of water vapour with surfaces other than glassy carbon is avoided completely. The carrier gas is introduced at the bottom of the reactor thereby flushing the outer tube compartment of the tube-in-tube assembly before entering the active heart of the reactor. With the Leipzig high-temperature reactor (HTP) similar precision was obtained with a minor modification (electropolishing) of the injector metal sleeve. With this system, the temperature dependence of the reaction has been studied between 1100 and 1450degreesC. Complete yield and constant isotope ratio information has been observed only for temperatures above 1325degreesC. For temperatures above 1300degreesC the reactor produces an increasing amount of CO background from reaction of glass carbon with the ceramic tube. This limits the usable temperature to a maximum of 1450degreesC. Relevant gas permeation through the Al2O3 walls has not been detected up to 1600degreesC. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:2650 / 2660
页数:11
相关论文
共 50 条
  • [1] A statistical analysis of IRMS and CRDS methods in isotopic ratios of 2H/1H and 18O/16O in water
    Tárcio Henrique Ribeiro dos Santos
    Maria do Rosário Zucchi
    Thierry Jacques Lemaire
    Antonio Expedito Gomes de Azevedo
    Denise Nunes Viola
    SN Applied Sciences, 2019, 1
  • [2] A statistical analysis of IRMS and CRDS methods in isotopic ratios of 2H/1H and 18O/16O in water
    Ribeiro dos Santos, Tarcio Henrique
    Zucchi, Maria do Rosario
    Lemaire, Thierry Jacques
    Gomes de Azevedo, Antonio Expedito
    Viola, Denise Nunes
    SN APPLIED SCIENCES, 2019, 1 (07):
  • [3] The use of Nafion membranes to measure 2H/1H and 18O/16O isotopic ratios in water
    Dias, V. Lopez
    Hoang, H. Q.
    Martinez-Carreras, N.
    Barnich, F.
    Wirtz, T.
    McDonnell, J. J.
    Pfister, L.
    JOURNAL OF MEMBRANE SCIENCE, 2019, 572 : 128 - 139
  • [4] Simultaneous determination of the 2H/1H, 17O/16O, and 18O/16O isotope abundance ratios in water by means of laser spectrometry
    Kerstel, ERT
    van Trigt, R
    Dam, N
    Reuss, J
    Meijer, HAJ
    ANALYTICAL CHEMISTRY, 1999, 71 (23) : 5297 - 5303
  • [5] Simultaneous analysis of 17O/16O, 18O/16O and 2H/1H of gypsum hydration water by cavity ring-down laser spectroscopy
    Gazquez, Fernando
    Mather, Ian
    Rolfe, James
    Evans, Nicholas P.
    Herwartz, Daniel
    Staubwasser, Michael
    Hodell, David A.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2015, 29 (21) : 1997 - 2006
  • [6] Comparison between IRMS and CRDS Methods in the Determination of Isotopic Ratios 2H/1H and 18O/16O in Water
    Santos, T. H. R.
    Zucchi, M. R.
    Lemaire, T.
    Azevedo, A. E. G.
    XXXV BRAZILIAN WORKSHOP ON NUCLEAR PHYSICS, 2013, 1529 : 107 - 109
  • [7] Identification and correction of spectral contamination in 2H/1H and 18O/16O measured in leaf, stem, and soil water
    Schultz, Natalie M.
    Griffis, Timothy J.
    Lee, Xuhui
    Baker, John M.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (21) : 3360 - 3368
  • [8] Determination of the 2H/1H, 17O/16O, and 18O/16O isotope ratios in water by means of tunable diode laser spectroscopy at 1.39 μm
    Kerstel, ERT
    Gagliardi, G
    Gianfrani, L
    Meijer, HAJ
    van Trigt, R
    Ramaker, R
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2002, 58 (11) : 2389 - 2396
  • [9] The impact of temperature on the water isotope (2H/1H, 17O/16O, 18O/16O) fractionation upon transport through a low-density polyethylene membrane
    Boettcher, Michael Ernst
    Schmiedinger, Iris
    ISOTOPES IN ENVIRONMENTAL AND HEALTH STUDIES, 2021, 57 (02) : 183 - 192
  • [10] Chemical and stable isotope composition (18O/16O, 2H/1H) of formation waters from the Carabobo Oilfield, Venezuela
    Boschetti, T.
    Angulo, B.
    Quintero, F.
    Volcan, J.
    Casalins, A.
    GEOLOGICA ACTA, 2018, 16 (03) : 257 - +