Continuous flow 2H/1H and and18O/16O analysis of water samples with dual inlet precision

被引:223
|
作者
Gehre, M
Geilmann, H
Richter, J
Werner, RA
Brand, WA
机构
[1] Max Planck Inst Biogeochem, D-07701 Jena, Germany
[2] UFZ Helmholtz Ctr Environm Res, D-04318 Leipzig, Germany
关键词
D O I
10.1002/rcm.1672
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method for isotope ratio analysis of water samples is described comprising an on-line high-temperature reduction technique in a helium carrier gas. Using a gas-tight syringe, injection of 0.5 to 1 muL sample is made through a heated septum into a glassy carbon reactor at temperatures in excess of 1300degreesC. More than 150 injections can be made per day and both isotope ratios of interest delta(2)H and 6180, can be measured with the same setup. The technique has the capability to transfer high-precision stable isotope ratio analysis of water samples from a specialized to a routine laboratory task compatible with other common techniques (automated injection for GC, LC, etc.). Experiments with an emphasis on the reactor design were made in two different laboratories using two different commercially available high-temperature elemental analyser (EA) systems. In the Jena TC/EA unit, sample-to-sample memory (single injection) has been reduced to similar to1% and high precision of about 0.1parts per thousand for delta(18)O and <1parts per thousand for delta(2)H has been achieved by a redesign of the glassy carbon reactor and by redirecting the gas flow of the commercial TC/EA unit. With the modified reactor, the contact of water vapour with surfaces other than glassy carbon is avoided completely. The carrier gas is introduced at the bottom of the reactor thereby flushing the outer tube compartment of the tube-in-tube assembly before entering the active heart of the reactor. With the Leipzig high-temperature reactor (HTP) similar precision was obtained with a minor modification (electropolishing) of the injector metal sleeve. With this system, the temperature dependence of the reaction has been studied between 1100 and 1450degreesC. Complete yield and constant isotope ratio information has been observed only for temperatures above 1325degreesC. For temperatures above 1300degreesC the reactor produces an increasing amount of CO background from reaction of glass carbon with the ceramic tube. This limits the usable temperature to a maximum of 1450degreesC. Relevant gas permeation through the Al2O3 walls has not been detected up to 1600degreesC. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:2650 / 2660
页数:11
相关论文
共 50 条
  • [31] Isotopic (δ18O and δ2H) Integrity of Water Samples Collected and Stored by Automatic Samplers
    Williams, Mark R.
    Lartey, Jessica L.
    Sanders, Laura L.
    AGRICULTURAL & ENVIRONMENTAL LETTERS, 2018, 3 (01)
  • [32] A new method for high-precision measurements of 17O/16O ratios in H2O
    Affek, Hagit P.
    Barkan, Eugeni
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2018, 32 (23) : 2096 - 2097
  • [33] Constraining the global composition of D/H and 18O/16O in Martian water using SOFIA/EXES
    Alday, J.
    Aoki, S.
    DeWitt, C.
    Montmessin, F.
    Holmes, J. A.
    Patel, M. R.
    Mason, J. P.
    Encrenaz, T.
    Richter, M. J.
    Irwin, P. G. J.
    Daerden, F.
    Terada, N.
    Nakagawa, H.
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2024, 530 (03) : 2919 - 2932
  • [34] High-precision δ2H and δ18O measurement for water and volatile organic compounds by continuous-flow pyrolysis isotope ratio mass spectroetry
    Begley, Ian S.
    Scrimgeour, Charles M.
    Analytical Chemistry, 1997, 69 (08):
  • [35] Sampling soil water along the pF curve for δ2H and δ18O analysis
    Orlowski, Natalie
    Breuer, Lutz
    HYDROLOGICAL PROCESSES, 2020, 34 (25) : 4959 - 4972
  • [36] 2H and 18O depletion of water close to organic surfaces
    Chen, Guo
    Auerswald, Karl
    Schnyder, Hans
    BIOGEOSCIENCES, 2016, 13 (10) : 3175 - 3186
  • [37] Comparative hepatic gene expression profiling of rats treated with 1H, 1H, 2H, 2H-heptadecafluorodecan-1-o1 or with pentadecafluorooctanoic acid
    Nilsen, Anja Julie
    Landin, Maria A.
    Haug, Kristin H.
    Fonnum, Frode
    Berger, Urs
    Osmundsen, Harald
    PHYSIOLOGICAL GENOMICS, 2008, 34 (03) : 285 - 303
  • [38] The H-1-H-2, O-17-H-1 coupling constants and the O-16/O-18 induced proton isotope shift in water
    Sergeyev, NM
    Sergeyeva, ND
    Strelenko, YA
    Raynes, WT
    CHEMICAL PHYSICS LETTERS, 1997, 277 (1-3) : 142 - 146
  • [39] Accuracy and precision of a laser-spectroscopy approach to the analysis of δ2H and δ18O in human urine
    O'Grady, Shannon P.
    Enright, Lindsey E.
    Barnette, Janet E.
    Cerling, Thure E.
    Ehleringer, James R.
    ISOTOPES IN ENVIRONMENTAL AND HEALTH STUDIES, 2010, 46 (04) : 476 - 483
  • [40] Disparate relationships between pH and goethite-water 18O/16O and D/H fractionation factors
    Yapp, Crayton J.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2022, 338 : 54 - 65