The use of Nafion membranes to measure 2H/1H and 18O/16O isotopic ratios in water

被引:0
|
作者
Dias, V. Lopez [1 ]
Hoang, H. Q. [1 ]
Martinez-Carreras, N. [2 ]
Barnich, F. [2 ]
Wirtz, T. [1 ]
McDonnell, J. J. [3 ]
Pfister, L. [2 ,4 ]
机构
[1] LIST, MRT Dept, Adv Instrumentat Ion Nanoanalyt AINA, 41 Rue Brill, L-4422 Belvaux, Luxembourg
[2] LIST, Environm Res & Innovat ERIN, Catchment & Ecohydrol Res Grp CAT, 41 Rue Brill, L-4422 Belvaux, Luxembourg
[3] Univ Saskatchewan, Global Inst Water Secur, 11 Innovat Blvd, Saskatoon, SK S7N 3H5, Canada
[4] Univ Luxembourg, Fac Sci Commun & Technol, Esch Sur Alzette, Luxembourg
关键词
Nafion membrane; MI inlet; MIMS inlet; Isotopic fractionation; Water analysis; delta O-18; delta H-2; O-18/O-16 isotopic ratios and H-2/H-1 isotopic ratios; INTRODUCTION MASS-SPECTROMETRY; STABLE-ISOTOPES; IN-SITU; TRANSPORT; SORPTION; TEMPERATURE; DESORPTION; QUANTIFICATION; CONTAMINANTS; CIRCULATION;
D O I
10.1016/j.memsci.2018.11.003
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The isotopic composition of water (H-2/H-1 and O-18/O-16) has been widely used in hydrology, ecology, paleoclimatology and forensic science. However, sampling frequency limits many such studies and there is now a clear need for field-portable mass spectrometer and laser-based spectrometer devices to measure water isotopic composition in-situ and at high temporal resolution. Here we explore the use of Nafion membranes as a potential Membrane Introduction (MI) inlet system for high frequency isotope analysis. As yet, the fractionation behaviour of H-2/H-1 and O-18/O-16 isotopic ratios in water transported through Nafion membranes has not been investigated. We quantify this behaviour for water samples with different matrices (organic matter and pollutants) and salinity concentrations across a wide range of isotopic ratios and different membrane thicknesses. Nafion membranes showed no fractionation effects on reported isotope ratios for natural waters. Also no fractionation effects were detected with salinity. Membrane thickness affected slightly the precision and accuracy of the isotopic ratio analysis and our tests showed that thinner Nafion membranes provide better results. However, for samples contaminated with organic matter, the thicker membranes performed better for the H-2/H-1 isotopic ratio, while for samples contaminated with pollutants, the thicker membranes performed better for the O-18/O-16 isotopic ratio. Overall, Nafion membranes appear well suited to MI inlet use and our work suggests that the optimal Nafion membrane thickness is 50-150 mu m.
引用
收藏
页码:128 / 139
页数:12
相关论文
共 50 条
  • [1] A statistical analysis of IRMS and CRDS methods in isotopic ratios of 2H/1H and 18O/16O in water
    Ribeiro dos Santos, Tarcio Henrique
    Zucchi, Maria do Rosario
    Lemaire, Thierry Jacques
    Gomes de Azevedo, Antonio Expedito
    Viola, Denise Nunes
    [J]. SN APPLIED SCIENCES, 2019, 1 (07)
  • [2] A statistical analysis of IRMS and CRDS methods in isotopic ratios of 2H/1H and 18O/16O in water
    Tárcio Henrique Ribeiro dos Santos
    Maria do Rosário Zucchi
    Thierry Jacques Lemaire
    Antonio Expedito Gomes de Azevedo
    Denise Nunes Viola
    [J]. SN Applied Sciences, 2019, 1
  • [3] Comparison between IRMS and CRDS Methods in the Determination of Isotopic Ratios 2H/1H and 18O/16O in Water
    Santos, T. H. R.
    Zucchi, M. R.
    Lemaire, T.
    Azevedo, A. E. G.
    [J]. XXXV BRAZILIAN WORKSHOP ON NUCLEAR PHYSICS, 2013, 1529 : 107 - 109
  • [4] Simultaneous determination of the 2H/1H, 17O/16O, and 18O/16O isotope abundance ratios in water by means of laser spectrometry
    Kerstel, ERT
    van Trigt, R
    Dam, N
    Reuss, J
    Meijer, HAJ
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (23) : 5297 - 5303
  • [5] Determination of the 2H/1H, 17O/16O, and 18O/16O isotope ratios in water by means of tunable diode laser spectroscopy at 1.39 μm
    Kerstel, ERT
    Gagliardi, G
    Gianfrani, L
    Meijer, HAJ
    van Trigt, R
    Ramaker, R
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2002, 58 (11) : 2389 - 2396
  • [6] Identification and correction of spectral contamination in 2H/1H and 18O/16O measured in leaf, stem, and soil water
    Schultz, Natalie M.
    Griffis, Timothy J.
    Lee, Xuhui
    Baker, John M.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (21) : 3360 - 3368
  • [7] Simultaneous analysis of 17O/16O, 18O/16O and 2H/1H of gypsum hydration water by cavity ring-down laser spectroscopy
    Gazquez, Fernando
    Mather, Ian
    Rolfe, James
    Evans, Nicholas P.
    Herwartz, Daniel
    Staubwasser, Michael
    Hodell, David A.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2015, 29 (21) : 1997 - 2006
  • [8] The impact of temperature on the water isotope (2H/1H, 17O/16O, 18O/16O) fractionation upon transport through a low-density polyethylene membrane
    Boettcher, Michael Ernst
    Schmiedinger, Iris
    [J]. ISOTOPES IN ENVIRONMENTAL AND HEALTH STUDIES, 2021, 57 (02) : 183 - 192
  • [9] Preservation and modification of the isotopic composition (18O/16O and 2H/1H) of structurally-bound hydration water of gypsum (CaSO4•2H2O) in aqueous solution
    Gazquez, Fernando
    Hodell, David A.
    [J]. GEOCHIMICA ET COSMOCHIMICA ACTA, 2022, 337 : 73 - 81
  • [10] Chemical and Isotopic (18O/16O and D/1H) Composition of Groundwaters of Central and Southern Primorye
    Chudaeva, V. A.
    Chudaev, O. V.
    Yurchenko, S. G.
    [J]. RUSSIAN JOURNAL OF PACIFIC GEOLOGY, 2008, 2 (06) : 512 - 520