In vitro and in vivo biocompatibility of substituted cellulose and synthetic membranes

被引:10
|
作者
Mandolfo, S
Tetta, C
David, S
Gervasio, R
Ognibene, D
Wratten, ML
Tessore, E
Imbasciati, E
机构
[1] Univ Parma, Chair Nephrol, I-43100 Parma, Italy
[2] Bellco, Res Dept, Clin Lab, Mirandola, MO, Italy
[3] Dept Nephrol & Hemodialysis, Lodi, Italy
来源
关键词
cellulose; biocompatibility; cytokines; complement; leukocyte adherence;
D O I
10.1177/039139889702001102
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Regenerated cellulosic membranes are held as bioincompatible due to their high complement - and leukopenia - inducing properties. Adherence of polymorphonuclear neutrophils and monocyte purified from normal human blood to the three membranes were evaluated in an in vitro recirculation circuit in the presence or absence of fresh, autologous plasma after recirculation in an in vitro circuit using minimodules with each of the three membranes. In in vivo studies, 9 patients were treated with conventional haemodialysis for 2 weeks with each membrane and I week for wash-out using haemodialysers with the following surface: 1.95 m(2) for benzyl-cellulose, 1.8 m(2) for acetate-cellulose and low-flux polysulfone. Measurement of leukopenia, plasma C3a des Arg and elastase-oc I proteinase inhibitor complex levels as well as urea, creatinine, phosphate and uric acid clearances was performed. Plasma-free neutrophils adhered maximally to acetate-cellulose (65% remaining in the circulation), while there was no significant difference between low-flux polysulfone and benzyl-cellulose (80% circulating neutrophils, at 15 min, p<0.001 vs acetate cellulose). In the presence of fresh plasma, as source of complement, the differences between acetate cellulose vs polysulfone and benzyl-cellulose were even more evident, suggesting the role of complement-activated products in neutrophil adherence. A similar trend was observed for monocyte adherence with the three membranes in the absence or presence of plasma. In vivo studies showed that the nadir of leukopenia was at 15 and 30 min with acetate-cellulose (79%) and benzyl-cellulose (50%) (p<0.05 acetate-vs benzyl-cellulose) and at 15 min with polysulfone (24%) (p<0.01 vs acetate-and benzyl-cellulose). Plasma C3a des Arg levels arose to 2037 +/- 120 ng/ml, 1216 + 434 ng/ml and 46 +/- 55 ng/ml with acetate-, benzyl-cellulose and polysulfone, respectively. No pre-vs post-dialysis increase in the intracellular content of TNF-alpha was detected with any of three membranes. Clearance values of urea, creatinine and uric acid were superimposable for all the three membranes. However, benzyl cellulose had a significantly higher clearance for phosphorus (normalized for surface area) (p<0.01 vs acetate-cellulose, 0.001 vs polysulfone). These results implicate that synthetic modification of the cellulose polymer as for the benzyl-cellulose significantly reduces the in vitro adherence, delays the in vivo activation of "classic" biocompatibility parameters and notably improves the removal of inorganic phosphorus.
引用
收藏
页码:603 / 609
页数:7
相关论文
共 50 条
  • [41] Biocompatibility of carbon composites: comparison of in vitro and in vivo observations
    LewandowskaSzumiel, M
    Komender, J
    Kudelska, D
    Mazur, M
    ANIMAL ALTERNATIVES, WELFARE, AND ETHICS, 1997, 27 : 927 - 933
  • [42] In vivo and in vitro biocompatibility of a new fibrous glassy scaffold
    Gabbai-Armelin, P.
    Souza, M.
    Kido, H.
    Tim, C.
    Bossini, P.
    Fernandes, K.
    Magri, A.
    Peitl-filho, O.
    Parizotto, N.
    Fernandes, K.
    Mesquita-ferrari, R.
    Ribeirto, D.
    Renno, A.
    JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2014, 8 : 326 - 326
  • [43] Injectable cellulose-based hydrogels as nucleus pulposus replacements: Assessment of in vitro structural stability, ex vivo herniation risk, and in vivo biocompatibility
    Lin, Huizi Anna
    Varma, Devika M.
    Hom, Warren W.
    Cruz, Michelle A.
    Nasser, Philip R.
    Phelps, Robert G.
    Iatridis, James C.
    Nicoll, Steven B.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2019, 96 : 204 - 213
  • [44] In Vitro and In Vivo Biocompatibility of a Novel, 3-Dimensional Cellulose Matrix Structure (vol 47, pg 378, 2015)
    Dunda, S. E.
    Ranker, M.
    Pallua, N.
    HANDCHIRURGIE MIKROCHIRURGIE PLASTISCHE CHIRURGIE, 2015, 47 (06) : e1 - e1
  • [45] BIOCOMPATIBILITY OF CELLULOSE AND CELLULOSE DERIVATIVES
    IZEBOUD, E
    PAPIER, 1992, 46 (12): : 722 - 725
  • [46] Polyamide 6 composite membranes:: Properties and in vitro biocompatibility evaluation
    Risbud, MV
    Bhonde, RR
    JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2001, 12 (01) : 125 - 136
  • [47] Synthetic nanostructured wollastonite: Composition, structure and "in vitro" biocompatibility investigation
    Papynov, E. K.
    Shichalin, O. O.
    Apanasevich, V. I.
    Plekhova, N. G.
    Buravlev, I. Yu
    Zinoviev, S. V.
    Mayorov, V. Yu
    Fedorets, A. N.
    Merkulov, E. B.
    Shlyk, D. Kh
    Nepomnyushchaya, V. A.
    Kornakova, Z. E.
    Afonin, I. S.
    Evdokimov, I. O.
    Korshunova, O. V.
    CERAMICS INTERNATIONAL, 2021, 47 (16) : 22487 - 22496
  • [48] In Vitro Physico-Chemical Characterization and Standardized In Vivo Evaluation of Biocompatibility of a New Synthetic Membrane for Guided Bone Regeneration
    Pereira, Livia da Costa
    de Almeida Barros Mourao, Carlos Fernando
    Neves Novellino Alves, Adriana Terezinha
    de Brito Resende, Rodrigo Figueiredo
    Pinheiro Guedes de Uzeda, Marcelo Jose
    Granjeiro, Jose Mauro
    Louro, Rafael Seabra
    Calasans-Maia, Monica Diuana
    MATERIALS, 2019, 12 (07)
  • [49] DNA nanostructures in vitro, in vivo and on membranes
    Bae, Wooli
    Kocabey, Samet
    Liedl, Tim
    NANO TODAY, 2019, 26 : 98 - 107
  • [50] In vitro and in vivo evaluation of e-PTFE and alkali-cellulose membranes for guided bone regeneration
    Salata, LA
    Hatton, PV
    Devlin, AJ
    Craig, GT
    Brook, IM
    CLINICAL ORAL IMPLANTS RESEARCH, 2001, 12 (01) : 62 - 68