In vitro and in vivo biocompatibility of substituted cellulose and synthetic membranes

被引:10
|
作者
Mandolfo, S
Tetta, C
David, S
Gervasio, R
Ognibene, D
Wratten, ML
Tessore, E
Imbasciati, E
机构
[1] Univ Parma, Chair Nephrol, I-43100 Parma, Italy
[2] Bellco, Res Dept, Clin Lab, Mirandola, MO, Italy
[3] Dept Nephrol & Hemodialysis, Lodi, Italy
来源
关键词
cellulose; biocompatibility; cytokines; complement; leukocyte adherence;
D O I
10.1177/039139889702001102
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Regenerated cellulosic membranes are held as bioincompatible due to their high complement - and leukopenia - inducing properties. Adherence of polymorphonuclear neutrophils and monocyte purified from normal human blood to the three membranes were evaluated in an in vitro recirculation circuit in the presence or absence of fresh, autologous plasma after recirculation in an in vitro circuit using minimodules with each of the three membranes. In in vivo studies, 9 patients were treated with conventional haemodialysis for 2 weeks with each membrane and I week for wash-out using haemodialysers with the following surface: 1.95 m(2) for benzyl-cellulose, 1.8 m(2) for acetate-cellulose and low-flux polysulfone. Measurement of leukopenia, plasma C3a des Arg and elastase-oc I proteinase inhibitor complex levels as well as urea, creatinine, phosphate and uric acid clearances was performed. Plasma-free neutrophils adhered maximally to acetate-cellulose (65% remaining in the circulation), while there was no significant difference between low-flux polysulfone and benzyl-cellulose (80% circulating neutrophils, at 15 min, p<0.001 vs acetate cellulose). In the presence of fresh plasma, as source of complement, the differences between acetate cellulose vs polysulfone and benzyl-cellulose were even more evident, suggesting the role of complement-activated products in neutrophil adherence. A similar trend was observed for monocyte adherence with the three membranes in the absence or presence of plasma. In vivo studies showed that the nadir of leukopenia was at 15 and 30 min with acetate-cellulose (79%) and benzyl-cellulose (50%) (p<0.05 acetate-vs benzyl-cellulose) and at 15 min with polysulfone (24%) (p<0.01 vs acetate-and benzyl-cellulose). Plasma C3a des Arg levels arose to 2037 +/- 120 ng/ml, 1216 + 434 ng/ml and 46 +/- 55 ng/ml with acetate-, benzyl-cellulose and polysulfone, respectively. No pre-vs post-dialysis increase in the intracellular content of TNF-alpha was detected with any of three membranes. Clearance values of urea, creatinine and uric acid were superimposable for all the three membranes. However, benzyl cellulose had a significantly higher clearance for phosphorus (normalized for surface area) (p<0.01 vs acetate-cellulose, 0.001 vs polysulfone). These results implicate that synthetic modification of the cellulose polymer as for the benzyl-cellulose significantly reduces the in vitro adherence, delays the in vivo activation of "classic" biocompatibility parameters and notably improves the removal of inorganic phosphorus.
引用
收藏
页码:603 / 609
页数:7
相关论文
共 50 条
  • [31] Future challenges in the in vitro and in vivo evaluation of biomaterial biocompatibility
    Anderson J.M.
    Anderson, James M. (jma6@case.edu), 2016, Oxford University Press (03) : 73 - 77
  • [32] In vitro and in vivo evaluation of SU-8 biocompatibility
    Nemani, Krishnamurthy V.
    Moodie, Karen L.
    Brennick, Jeoffry B.
    Su, Alison
    Gimi, Barjor
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2013, 33 (07): : 4453 - 4459
  • [33] Nanoparticle Interactions with Living Systems: In Vivo and In Vitro Biocompatibility
    Panessa-Warren, Barbara J.
    Warrren, John B.
    Maye, Mathew M.
    Schiffer, Wynne
    NANOPARTICLES AND NANODEVICES IN BIOLOGICAL APPLICATIONS: THE INFN LECTURES - VOL I, 2009, 4 : 1 - 45
  • [34] In vivo and in vitro biocompatibility of two adhesive systems.
    Demarco, FF
    Tarquinio, SBC
    Jaeger, MMM
    Araújo, VC
    Matson, E
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 927 - 927
  • [35] IN-VIVO EVALUATION OF 4 HEMODIALYSIS MEMBRANES - BIOCOMPATIBILITY AND CLEARANCES
    OOSTERHUIS, WP
    DEMETZ, M
    WADHAM, A
    DAHA, MR
    GO, RH
    DIALYSIS & TRANSPLANTATION, 1995, 24 (08) : 450 - &
  • [36] Future challenges in the in vitro and in vivo evaluation of biomaterial biocompatibility
    Anderson, James M.
    REGENERATIVE BIOMATERIALS, 2016, 3 (02) : 73 - 77
  • [37] In vitro and in vivo biocompatibility testing of absorbable metal stents
    Loos, Anneke
    Rohde, Roland
    Haveich, Axel
    Barlach, Sabine
    MACROMOLECULAR SYMPOSIA, 2007, 253 : 103 - 108
  • [38] HIGH FLUX AND CELLULOSIC MEMBRANES: BIOCOMPATIBILITY AND IN VIVO CLEARANCES.
    Petersen, Jeffrey
    Hyver, Scott
    Yeh, Isabella
    ASAIO Transactions, 1987, 33 (03): : 265 - 268
  • [39] In vitro and in vivo biocompatibility assessment of chalcogenide thermoelectrics as implants
    Gao, Mingyuan
    Luo, Yiping
    Li, Wen
    Zheng, Longpo
    Pei, Yanzhong
    JOURNAL OF MATERIALS CHEMISTRY B, 2024, 12 (28) : 6847 - 6855
  • [40] IN VITRO AND IN VIVO EVALUATION OF LYOPHILIZED BOVINE BONE BIOCOMPATIBILITY
    Galia, Carlos Roberto
    Macedo, Carlos Alberto
    Rosito, Ricardo
    de Mello, Tielle Muller
    Araujo Quaresma Camargo, Lourdes Maria
    Moreira, Luis Fernando
    CLINICS, 2008, 63 (06) : 801 - 806