In vitro and in vivo biocompatibility of substituted cellulose and synthetic membranes

被引:10
|
作者
Mandolfo, S
Tetta, C
David, S
Gervasio, R
Ognibene, D
Wratten, ML
Tessore, E
Imbasciati, E
机构
[1] Univ Parma, Chair Nephrol, I-43100 Parma, Italy
[2] Bellco, Res Dept, Clin Lab, Mirandola, MO, Italy
[3] Dept Nephrol & Hemodialysis, Lodi, Italy
来源
关键词
cellulose; biocompatibility; cytokines; complement; leukocyte adherence;
D O I
10.1177/039139889702001102
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Regenerated cellulosic membranes are held as bioincompatible due to their high complement - and leukopenia - inducing properties. Adherence of polymorphonuclear neutrophils and monocyte purified from normal human blood to the three membranes were evaluated in an in vitro recirculation circuit in the presence or absence of fresh, autologous plasma after recirculation in an in vitro circuit using minimodules with each of the three membranes. In in vivo studies, 9 patients were treated with conventional haemodialysis for 2 weeks with each membrane and I week for wash-out using haemodialysers with the following surface: 1.95 m(2) for benzyl-cellulose, 1.8 m(2) for acetate-cellulose and low-flux polysulfone. Measurement of leukopenia, plasma C3a des Arg and elastase-oc I proteinase inhibitor complex levels as well as urea, creatinine, phosphate and uric acid clearances was performed. Plasma-free neutrophils adhered maximally to acetate-cellulose (65% remaining in the circulation), while there was no significant difference between low-flux polysulfone and benzyl-cellulose (80% circulating neutrophils, at 15 min, p<0.001 vs acetate cellulose). In the presence of fresh plasma, as source of complement, the differences between acetate cellulose vs polysulfone and benzyl-cellulose were even more evident, suggesting the role of complement-activated products in neutrophil adherence. A similar trend was observed for monocyte adherence with the three membranes in the absence or presence of plasma. In vivo studies showed that the nadir of leukopenia was at 15 and 30 min with acetate-cellulose (79%) and benzyl-cellulose (50%) (p<0.05 acetate-vs benzyl-cellulose) and at 15 min with polysulfone (24%) (p<0.01 vs acetate-and benzyl-cellulose). Plasma C3a des Arg levels arose to 2037 +/- 120 ng/ml, 1216 + 434 ng/ml and 46 +/- 55 ng/ml with acetate-, benzyl-cellulose and polysulfone, respectively. No pre-vs post-dialysis increase in the intracellular content of TNF-alpha was detected with any of three membranes. Clearance values of urea, creatinine and uric acid were superimposable for all the three membranes. However, benzyl cellulose had a significantly higher clearance for phosphorus (normalized for surface area) (p<0.01 vs acetate-cellulose, 0.001 vs polysulfone). These results implicate that synthetic modification of the cellulose polymer as for the benzyl-cellulose significantly reduces the in vitro adherence, delays the in vivo activation of "classic" biocompatibility parameters and notably improves the removal of inorganic phosphorus.
引用
收藏
页码:603 / 609
页数:7
相关论文
共 50 条
  • [21] In vitro and in vivo studies on biocompatibility of carbon fibres
    Rajzer, Izabella
    Menaszek, Elzbieta
    Bacakova, Lucie
    Rom, Monika
    Blazewicz, Marta
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2010, 21 (09) : 2611 - 2622
  • [22] BIOCOMPATIBILITY OF CUPROPHAN AND CELLULOSE-ACETATE MEMBRANES DURING HEMODIALYSIS
    GREKAS, D
    SYRGANIS, C
    ZEGLA, O
    KOUTOUPI, S
    VASILERI, H
    TOURKANTONIS, A
    KIDNEY INTERNATIONAL, 1985, 28 (02) : 327 - 327
  • [23] The in vitro and in vivo evaluation of the biocompatibility of Mg alloys
    Walker, J.
    Shadanbaz, S.
    Woodfield, T. B. F.
    Staiger, M. P.
    Dias, G. J.
    BIOMEDICAL MATERIALS, 2014, 9 (01)
  • [24] In vivo evaluation of biocompatibility and biodegradation of porcine collagen membranes
    Kim, Seon Ae
    Go, Eun Jeong
    Bae, Bo Seung
    Jung, Jae Woong
    Cho, Mi-La
    Shetty, Asode Ananthram
    Kim, Seok Jung
    REGENERATIVE THERAPY, 2025, 29 : 292 - 302
  • [25] Biocompatibility and osteogenic potential of mineral trioxide aggregate mixed with hydrophilic synthetic polymer: An in vitro and in vivo study
    Park, Eun Hyun
    Rhee, Sang-Hoon
    Choi, Hae Won
    Shon, Won-Jun
    DENTAL MATERIALS JOURNAL, 2022, 41 (05) : 780 - 786
  • [26] In vitro and in vivo biocompatibility of decellularized cellulose scaffolds functionalized with chitosan and platelet rich plasma for tissue engineering applications
    Mahendiran, Balaji
    Muthusamy, Shalini
    Sampath, Sowndarya
    Jaisankar, S. N.
    Selvakumar, R.
    Krishnakumar, Gopal Shankar
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2022, 217 : 522 - 535
  • [27] Preparation, Characterization and In Vivo Biocompatibility Studies of Cotton Cellulose Nanofibers
    Gouveia, Ana C. C.
    Munk, Michele
    Oliveira, Virginia
    Ferreira, Ana P.
    Brandao, Humberto M.
    Gern, Juliana C.
    Brayner, Roberta
    Martins, Maria A.
    Raposo, Nadia R. B.
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2020, 20 (10) : 6532 - 6541
  • [28] CELLULOSE-BASED HEMODIALYSIS MEMBRANES - BIOCOMPATIBILITY AND FUNCTIONAL PERFORMANCE COMPARED
    WOFFINDIN, C
    HOENICH, NA
    MATTHEWS, JNS
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 1992, 7 (04) : 340 - 345
  • [29] Comparison of biocompatibility in cellulose triacetate dialysis membranes with homogeneous and asymmetric structures
    Togo K.
    Yamamoto M.
    Imai M.
    Akiyama K.
    Yamashita A.C.
    Renal Replacement Therapy, 4 (1)
  • [30] Silver nanoparticle/bacterial cellulose gel membranes for antibacterial wound dressing: investigation in vitro and in vivo
    Wu, Jian
    Zheng, Yudong
    Wen, Xiaoxiao
    Lin, Qinghua
    Chen, Xiaohua
    Wu, Zhigu