In vitro and in vivo biocompatibility of substituted cellulose and synthetic membranes

被引:10
|
作者
Mandolfo, S
Tetta, C
David, S
Gervasio, R
Ognibene, D
Wratten, ML
Tessore, E
Imbasciati, E
机构
[1] Univ Parma, Chair Nephrol, I-43100 Parma, Italy
[2] Bellco, Res Dept, Clin Lab, Mirandola, MO, Italy
[3] Dept Nephrol & Hemodialysis, Lodi, Italy
来源
关键词
cellulose; biocompatibility; cytokines; complement; leukocyte adherence;
D O I
10.1177/039139889702001102
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Regenerated cellulosic membranes are held as bioincompatible due to their high complement - and leukopenia - inducing properties. Adherence of polymorphonuclear neutrophils and monocyte purified from normal human blood to the three membranes were evaluated in an in vitro recirculation circuit in the presence or absence of fresh, autologous plasma after recirculation in an in vitro circuit using minimodules with each of the three membranes. In in vivo studies, 9 patients were treated with conventional haemodialysis for 2 weeks with each membrane and I week for wash-out using haemodialysers with the following surface: 1.95 m(2) for benzyl-cellulose, 1.8 m(2) for acetate-cellulose and low-flux polysulfone. Measurement of leukopenia, plasma C3a des Arg and elastase-oc I proteinase inhibitor complex levels as well as urea, creatinine, phosphate and uric acid clearances was performed. Plasma-free neutrophils adhered maximally to acetate-cellulose (65% remaining in the circulation), while there was no significant difference between low-flux polysulfone and benzyl-cellulose (80% circulating neutrophils, at 15 min, p<0.001 vs acetate cellulose). In the presence of fresh plasma, as source of complement, the differences between acetate cellulose vs polysulfone and benzyl-cellulose were even more evident, suggesting the role of complement-activated products in neutrophil adherence. A similar trend was observed for monocyte adherence with the three membranes in the absence or presence of plasma. In vivo studies showed that the nadir of leukopenia was at 15 and 30 min with acetate-cellulose (79%) and benzyl-cellulose (50%) (p<0.05 acetate-vs benzyl-cellulose) and at 15 min with polysulfone (24%) (p<0.01 vs acetate-and benzyl-cellulose). Plasma C3a des Arg levels arose to 2037 +/- 120 ng/ml, 1216 + 434 ng/ml and 46 +/- 55 ng/ml with acetate-, benzyl-cellulose and polysulfone, respectively. No pre-vs post-dialysis increase in the intracellular content of TNF-alpha was detected with any of three membranes. Clearance values of urea, creatinine and uric acid were superimposable for all the three membranes. However, benzyl cellulose had a significantly higher clearance for phosphorus (normalized for surface area) (p<0.01 vs acetate-cellulose, 0.001 vs polysulfone). These results implicate that synthetic modification of the cellulose polymer as for the benzyl-cellulose significantly reduces the in vitro adherence, delays the in vivo activation of "classic" biocompatibility parameters and notably improves the removal of inorganic phosphorus.
引用
收藏
页码:603 / 609
页数:7
相关论文
共 50 条
  • [1] In Vitro and In Vivo Biocompatibility of Bacterial Cellulose
    Girard, Vincent-Daniel
    Chausse, Jeremie
    Borduas, Martin
    Dubuc, Emile
    Iorio-Morin, Christian
    Brisebois, Simon
    Vermette, Patrick
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2024, 112 (10)
  • [2] In vivo biocompatibility of bacterial cellulose
    Helenius, G
    Bäckdahl, H
    Bodin, A
    Nannmark, U
    Gatenholm, P
    Risberg, B
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2006, 76A (02) : 431 - 438
  • [3] Comparative In Vivo Biocompatibility of Cellulose-Derived and Synthetic Meshes in Subcutaneous Transplantation Models
    Peltokallio, Nina M. M.
    Ajdary, Rubina
    Reyes, Guillermo
    Kankuri, Esko
    Junnila, Jouni J. T.
    Kuure, Satu
    Meller, Anna S.
    Kuula, Jani
    Raussi-Lehto, Eija
    Sariola, Hannu
    Laitinen-Vapaavuori, Outi M.
    Rojas, Orlando J.
    BIOMACROMOLECULES, 2024, 25 (11) : 7298 - 7310
  • [4] In vitro biocompatibility of different polyester membranes
    Vaquette, C.
    Fawzi-Grancher, S.
    Lavalle, P.
    Frochot, C.
    Viriot, M. -L.
    Muller, S.
    Wang, X.
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2006, 16 (04) : S131 - S136
  • [5] In Vitro and In Vivo Biocompatibility of Natural and Synthetic Pseudomonas aeruginosa Pyomelanin for Potential Biomedical Applications
    Urbaniak, Mateusz M.
    Gazinska, Malgorzata
    Rudnicka, Karolina
    Plocinski, Przemyslaw
    Nowak, Monika
    Chmiela, Magdalena
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2023, 24 (09)
  • [6] Evaluation of biocompatibility of polypyrrole in vitro and in vivo
    Wang, XD
    Gu, XS
    Yuan, CW
    Chen, SJ
    Zhang, PY
    Zhang, TY
    Yao, J
    Chen, F
    Chen, G
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2004, 68A (03) : 411 - 422
  • [7] In vivo biocompatibility of nanostructured Chitosan/Peo membranes
    Vulcani, V. A. S.
    Franzo, V. S.
    Rabelo, R. E.
    Rabbers, A. S.
    Assis, B. M.
    D'Avila, M. A.
    Antoni, S. M. B.
    ARQUIVO BRASILEIRO DE MEDICINA VETERINARIA E ZOOTECNIA, 2015, 67 (04) : 1039 - 1044
  • [8] In Vitro Evaluation of Biocompatibility and Immunocompatibility of 2,3 Dialdehyde Cellulose Hydrogel Membranes for Wound Healing
    Lacin, NelisaTurkoglu
    Kaplan, Engin
    Demirbilek, Murat
    Mazmanci, Mehmet Ali
    Mazmanci, Birgul
    Cavas, Tolga
    JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2017, 7 (09) : 822 - 828
  • [9] Selecting valid in vitro biocompatibility tests that predict the in vivo healing response of synthetic vascular prostheses
    Marois, Y
    Guidoin, R
    Roy, R
    Vidovsky, T
    Jakubiec, B
    SigotLuizard, MF
    Braybrook, J
    Mehri, Y
    Laroche, G
    King, M
    BIOMATERIALS, 1996, 17 (19) : 1835 - 1842
  • [10] In vitro Biocompatibility of HPC - modified Polyurethane Membranes
    Butnaru, Maria
    Dimitriu, Daniela Cristina
    Bredetean, Ovidiu
    Macocinschi, Doina
    Harabagiu, Valeria
    MATERIALE PLASTICE, 2015, 52 (03) : 290 - 294