Plastic scintillation dosimetry and its application to radiotherapy

被引:151
|
作者
Beddar, A. S. [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Div Radiat Oncol, Houston, TX 77030 USA
关键词
dosimetry; scintillators; scintillation detectors; fiberoptic detectors; radiotherapy detectors;
D O I
10.1016/j.radmeas.2007.01.002
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
We present a review of the dosimetric characteristics and properties of plastic scintillation detectors when exposed to high-energy photon and electron beams. The detectors show many desirable qualities, including water equivalence, energy independence, reproducibility, dose linearity, resistance to radiation damage, and near temperature independence. Therefore, these detectors do not require the usual conversion and/or correction factors used for other commonly used detectors to convert the dosimeter reading to absorbed dose. Furthermore, due to their small detecting volume, plastic scintillation detectors exhibit excellent spatial resolution. One issue concerning detector performance is the radiation-induced light arising in the optical fibers that carry the scintillator output to a photomultiplier tube or photodiode. The radiation induced light produced in optical fibers could be a combination of Cerenkov emission, fluorescence or luminescence depending on the type of material of the fibers utilized. For pure fused silica optical fibers, this spurious light emission is predominantly due to Cerenkov. This is most easily resolved by subtracting the signals from two sets of optical fibers, one carrying the entire signal and the other carrying just the Cerenkov background. Finally, we present two applications for plastic scintillation detectors in clinical radiotherapy: stereotactic radiosurgery dosimetry and the quality assurance of Co-60 and high-energy therapy beams. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S124 / S133
页数:10
相关论文
共 50 条
  • [1] Advances in plastic scintillation detectors dosimetry
    Beaulieu, L.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S182 - S182
  • [2] Pre-clinical and clinical evaluation of the HYPERSCINT plastic scintillation dosimetry research platform for in vivo dosimetry during radiotherapy
    Schoepper, Imke
    Dieterich, Sonja
    Trestrail, Earl Alonzo
    Kent, Michael Sean
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (04):
  • [3] Plastic Scintillation Detectors: Present Status and Their Application for Quality Assurance and in Vivo Dosimetry
    Beddar, S.
    Beaulieu, L.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [4] Plastic scintillation detector validation for kV dosimetry
    Lessard, F.
    Archambault, L.
    Plamondon, M.
    Despres, P.
    Therriault-Proulx, F.
    Beddar, S.
    Beaulieu, L.
    MEDICAL PHYSICS, 2012, 39 (07) : 4646 - 4646
  • [5] Plastic scintillator preparation and coupling in scintillation dosimetry
    Archambault, L.
    Ayotte, G.
    Gingras, L.
    Beddar, A.
    Beaulieu, L.
    MEDICAL PHYSICS, 2006, 33 (06) : 2129 - 2130
  • [6] The practical application of scintillation dosimetry in small-field photon-beam radiotherapy
    Burke, Elisa
    Poppinga, Daniela
    Schoenfeld, Andreas A.
    Harder, Dietrich
    Poppe, Bjoern
    Looe, Hui Khee
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2017, 27 (04): : 324 - 333
  • [7] Plastic scintillation dosimetry: optimization of light collection efficiency
    Beddar, AS
    Law, S
    Suchowerska, N
    Mackie, R
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (09): : 1141 - 1152
  • [8] Systematic Evaluation of Photodetectors Performances for Plastic Scintillation Dosimetry
    Boivin, J.
    Beddar, S.
    Guillemette, M.
    Beaulieu, L.
    MEDICAL PHYSICS, 2014, 41 (06) : 549 - 549
  • [9] Full Spectrum Cerenkov Correction for Plastic Scintillation Dosimetry
    Monajemi, T. T.
    MEDICAL PHYSICS, 2017, 44 (06) : 2988 - 2988
  • [10] Systematic evaluation of photodetector performance for plastic scintillation dosimetry
    Boivin, Jonathan
    Beddar, Sam
    Guillemette, Maxime
    Beaulieu, Luc
    MEDICAL PHYSICS, 2015, 42 (11) : 6211 - 6220