摘要
The objective of this paper is to demonstrate the practical investigations on reducing conducted emissions on power supply output line especially when it travels through cable for long distances (around 1.5 meters). Common mode chokes provides an effective EMI filtering solution and withstands high DC currents and allows the signal to pass unaffected. This paper aims to provide a solution to control the emissions which is coming out from the cables with the help of CMC. The conducted emission levels on the output lines were measured with and without EMI filter (CMC). The CE test result indicated the emission levels above the limit without CMC. With the addition of CMC the emission level found to be around 15 dB below the requirements of CISPIR22 EMI/EMC Standards for conducted emissions.
引用
收藏
页数:2
相关论文
共 50 条
  • [31] Modeling and Mitigation on Conducted Emission for Switch Mode Power Supply
    Qian, Xin
    Yan, Wei
    Sun, Pingdong
    Wang, Enrong
    [J]. 2016 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (APEMC), 2016, : 77 - 79
  • [32] DESIGN OF A COMPOSITE CABLE POWER-SUPPLY SYSTEM
    BUSHUYEV, VM
    SERGEICH.NM
    [J]. TELECOMMUNICATIONS AND RADIO ENGINEER-USSR, 1971, (09): : 40 - &
  • [33] POWER SUPPLY FOR TRANSISTORIZED COAXIAL PAIR CABLE SYSTEMS
    KOJIMA, N
    SAKAI, H
    [J]. REVIEW OF THE ELECTRICAL COMMUNICATIONS LABORATORIES, 1968, 16 (11-1): : 926 - &
  • [34] Failures induced on bipolar operational amplifiers from electromagnetic interferences conducted on the power supply rails
    Speciale, N
    Setti, G
    [J]. 1999 IEEE INTERNATIONAL RELIABILITY PHYSICS SYMPOSIUM PROCEEDINGS - 37TH ANNUAL, 1999, : 333 - 336
  • [35] A Dual-Output Power Supply Integrated High -Voltage Anode Power Supply and Filament Power Supply for Magnetrons
    Liu, Yang
    He, Zhixing
    Wang, Jing
    Li, Zongjian
    Wang, Lei
    Wang, Feng
    Li, Xiaobing
    Fang, Wanglin
    Luo, An
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2024, 71 (05) : 4629 - 4639
  • [36] Influence of Output Terminations on Common-Mode Conducted Emissions Evaluation of Interface Converters
    New, Christopher D.
    Lemmon, Andrew N.
    Brovont, Aaron D.
    [J]. IEEE OPEN JOURNAL OF POWER ELECTRONICS, 2024, 5 : 1182 - 1196
  • [37] Analysis of common mode conducted emissions applied switching power supplies
    Zola, Julio G.
    Belcaguy, Pablo Marino
    D'Angiolo, Federico
    [J]. 2016 IEEE GLOBAL ELECTROMAGNETIC COMPATIBILITY CONFERENCE (GEMCCON), 2016,
  • [38] Measurement of 2-150 kHz Conducted Emissions in Power Networks
    Ritzmann, Deborah
    Wright, Paul
    Meyer, Jan
    Khokhlov, Victor
    de la Vega, David
    Fernandez, Igor
    [J]. 2020 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM), 2020,
  • [39] Minimizing Data Center Uninterruptable Power Supply Overload by Server Power Capping
    Al-Hazemi, Fawaz
    Lorincz, Josip
    Mohammed, Alaelddin F. Y.
    [J]. IEEE COMMUNICATIONS LETTERS, 2019, 23 (08) : 1342 - 1346
  • [40] NEGATIVE OUTPUT RESISTANCE IN A REGULATED POWER SUPPLY
    DIAMOND, J
    [J]. ELECTRONIC ENGINEERING, 1965, 37 (453): : 749 - &