Minimizing Conducted Emissions from Power supply output cable

被引:0
|
作者
Chander, Mahender [1 ]
机构
[1] Honeywell Technol Solut Lab Pvt Ltd, HBT E&ES HWCoE, Bangalore, Karnataka, India
关键词
EMI; CE; CMC; CISPIR22;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The objective of this paper is to demonstrate the practical investigations on reducing conducted emissions on power supply output line especially when it travels through cable for long distances (around 1.5 meters). Common mode chokes provides an effective EMI filtering solution and withstands high DC currents and allows the signal to pass unaffected. This paper aims to provide a solution to control the emissions which is coming out from the cables with the help of CMC. The conducted emission levels on the output lines were measured with and without EMI filter (CMC). The CE test result indicated the emission levels above the limit without CMC. With the addition of CMC the emission level found to be around 15 dB below the requirements of CISPIR22 EMI/EMC Standards for conducted emissions.
引用
收藏
页数:2
相关论文
共 50 条
  • [21] A Terminal Ground Filter between Cable and Chassis for Reduction of Conducted Emissions at a Home Appliance
    Jeong, Sangyeong
    Kim, Jingook
    Baek, Youngjin
    Lee, Wonwoo
    Park, Gwigeun
    [J]. 2018 IEEE SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, SIGNAL INTEGRITY AND POWER INTEGRITY (EMC, SI & PI), 2018, : 414 - 418
  • [22] Experimental electromagnetic compatibility of conducted electromagnetic interferences from an IGBT and a MOSFET in the power supply
    Lahlaci, M. E.
    Miloudi, M.
    Miloudi, H.
    [J]. ELECTRICAL ENGINEERING & ELECTROMECHANICS, 2024, (03) : 38 - 43
  • [23] TRIPLE POWER-SUPPLY OUTPUT
    LANPHER, LS
    [J]. ELECTRONIC DESIGN, 1992, 40 (12) : 85 - 85
  • [24] Supply voltage strategies for minimizing the power of CMOS processors
    Cai, J
    Taur, Y
    Huang, SF
    Frank, DJ
    Kosonocky, S
    Dennard, RH
    [J]. 2002 SYMPOSIUM ON VLSI TECHNOLOGY, DIGEST OF TECHNICAL PAPERS, 2002, : 102 - 103
  • [25] MINIMIZING THE MASS OF A POTENTIAL RAILGUN POWER-SUPPLY
    JOHNSON, DE
    NOEL, AP
    CLEMENTS, ND
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 1991, 27 (01) : 429 - 432
  • [26] Prediction of radiated emissions by a power converter with an attached cable
    Leroux, E
    Giachino, C
    Ene, R
    [J]. ISIE '97 - PROCEEDINGS OF THE IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1-3, 1997, : SS218 - SS222
  • [27] Current output from sandwich-structured ferroelectric power supply
    Du, Jinmei
    Liu, Gaomin
    Liu, Yusheng
    Wang, Haiyan
    Zhang, Fuping
    He, Hongliang
    [J]. SHOCK COMPRESSION OF CONDENSED MATTER - 2007, PTS 1 AND 2, 2007, 955 : 167 - 170
  • [28] Analysis of conducted emissions from an Electric Nacelle Anti-Ice Power Control System
    Nothofer, Angela
    Tarisciotti, Luca
    Zhou, Qian
    Benson, Trevor
    Greedy, Steve
    Christopoulos, Christos
    [J]. PROCEEDINGS OF THE 2016 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY - EMC EUROPE, 2016, : 434 - 439
  • [29] Evaluation of the measurement uncertainties in the conducted emissions from adjustable speed electrical power drive systems
    Betta, G
    Capriglione, D
    Tomasso, G
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2004, 53 (04) : 963 - 968
  • [30] A conducted EMI model for an industrial power supply full bridge
    Brehaut, S
    Le Bunetel, JC
    Magnon, D
    [J]. PESC 04: 2004 IEEE 35TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, CONFERENCE PROCEEDINGS, 2004, : 3227 - 3231