Investigation of OPET performance using GATE, a Geant4-based simulation software

被引:22
|
作者
Rannou, FR [1 ]
Kohli, V
Prout, DL
Chatziioannou, AF
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Mol & Med Pharmacol, Crump Inst Mol Imaging, Los Angeles, CA 90095 USA
[2] Univ Santiago Chile, Dept Ingn Informat, Casilla 10233, Chile
关键词
GATE; Monte Carlo; optical; positron emission tomography (PET);
D O I
10.1109/TNS.2004.835737
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A combined optical positron emission tomography (OPET) system is capable of both optical and PET imaging in the same setting, and it can provide information/interpretation not possible in single-mode imaging. The scintillator array here serves the dual function of coupling the optical signal from bioluminescence/fluorescence to the photodetector and also of channeling optical scintillations from the gamma rays. We report simulation results of the PET part of OPET using GATE, a Geant4 simulation package. The purpose of this investigation is the definition of the geometric parameters of the OPET tomograph. OPET is composed of six detector blocks arranged in a hexagonal ring-shaped pattern with an inner radius of 15.6 mm. Each detector consists of a two-dimensional array of 8 x 8 scintillator crystals each measuring 2 x 2 x 10 mm(3). Monte Carlo simulations were performed using the GATE software to measure absolute sensitivity, depth of interaction, and spatial resolution for two ring configurations, with and without gantry rotations, two crystal materials, and several crystal lengths. Images were reconstructed with filtered backprojection after angular interleaving and transverse one-dimensional interpolation of the sinogram. We report absolute sensitivities nearly seven times that of the prototype microPET at the center of field of view and 2.0 mm tangential and 2.3 mm radial resolutions with gantry rotations up to an 8.0 mm radial offset. These performance parameters indicate that the imaging spatial resolution and sensitivity of the OPET system will be suitable for high-resolution and high-sensitivity small-animal PET imaging.
引用
下载
收藏
页码:2713 / 2717
页数:5
相关论文
共 50 条
  • [1] Investigation of OPET performance using GATE, a Geant4-based simulation software
    Rannou, F
    Kohli, V
    Prout, D
    Chatziioannou, A
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2048 - 2052
  • [2] The Geant4-Based Simulation Software of the ATLAS Detector
    Costanzo, D.
    Dell'Acqua, A.
    Gallas, M.
    Rimoldi, A.
    Boudreau, J.
    Tsulaia, V.
    Di Simone, A.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 5 - 11
  • [3] The Geant4-based BABAR simulation
    Wright, D
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 499 - 502
  • [4] GATE, a Geant4-based simulation platform for PET integrating movement and time management
    Santin, G
    Strul, D
    Lazaro, D
    Simon, L
    Krieguer, M
    Martins, MV
    Breton, V
    Morel, C
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1325 - 1329
  • [5] Validation of Geant4-Based Radioactive Decay Simulation
    Hauf, Steffen
    Kuster, Markus
    Batic, Matej
    Bell, Zane W.
    Hoffmann, Dieter H. H.
    Lang, Philipp M.
    Neff, Stephan
    Pia, Maria Grazia
    Weidenspointner, Georg
    Zoglauer, Andreas
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (04) : 2984 - 2997
  • [6] Geant4-based multiphysics simulation toolkit for analysis of radiation detector performance
    Guckes, Amber L.
    Green, J. Andrew
    Smalley, Duane D.
    Martin, Matthew A.
    Baker, Stuart A.
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XXI, 2019, 11114
  • [7] GATE: A Geant4-based simulation platform for PET and SPECT integrating movement and time management
    Santin, G
    Strul, D
    Lazaro, D
    Simon, L
    Krieguer, M
    Martins, MV
    Breton, V
    Morel, C
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) : 1516 - 1521
  • [8] An investigation of neutron weighting factors using a Geant4-based microdosimetry pipeline
    Lund, Christopher
    Famulari, Gabriel
    Montgomery, Logan
    Kildea, John
    MEDICAL PHYSICS, 2019, 46 (11) : 5391 - 5391
  • [9] Geant4-based simulation of a beam radiation monitor for SUPERB
    Cardarelli, R.
    Di Ciaccio, A.
    Di Simone, A.
    Tammaro, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 718 : 200 - 201
  • [10] MULASSIS: A Geant4-based multilayered shielding simulation tool
    Lei, F
    Truscott, PR
    Dyer, CS
    Quaghebeur, B
    Heynderickx, D
    Nieminen, P
    Evans, H
    Daly, E
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (06) : 2788 - 2793