Investigation of OPET performance using GATE, a Geant4-based simulation software

被引:22
|
作者
Rannou, FR [1 ]
Kohli, V
Prout, DL
Chatziioannou, AF
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Mol & Med Pharmacol, Crump Inst Mol Imaging, Los Angeles, CA 90095 USA
[2] Univ Santiago Chile, Dept Ingn Informat, Casilla 10233, Chile
关键词
GATE; Monte Carlo; optical; positron emission tomography (PET);
D O I
10.1109/TNS.2004.835737
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A combined optical positron emission tomography (OPET) system is capable of both optical and PET imaging in the same setting, and it can provide information/interpretation not possible in single-mode imaging. The scintillator array here serves the dual function of coupling the optical signal from bioluminescence/fluorescence to the photodetector and also of channeling optical scintillations from the gamma rays. We report simulation results of the PET part of OPET using GATE, a Geant4 simulation package. The purpose of this investigation is the definition of the geometric parameters of the OPET tomograph. OPET is composed of six detector blocks arranged in a hexagonal ring-shaped pattern with an inner radius of 15.6 mm. Each detector consists of a two-dimensional array of 8 x 8 scintillator crystals each measuring 2 x 2 x 10 mm(3). Monte Carlo simulations were performed using the GATE software to measure absolute sensitivity, depth of interaction, and spatial resolution for two ring configurations, with and without gantry rotations, two crystal materials, and several crystal lengths. Images were reconstructed with filtered backprojection after angular interleaving and transverse one-dimensional interpolation of the sinogram. We report absolute sensitivities nearly seven times that of the prototype microPET at the center of field of view and 2.0 mm tangential and 2.3 mm radial resolutions with gantry rotations up to an 8.0 mm radial offset. These performance parameters indicate that the imaging spatial resolution and sensitivity of the OPET system will be suitable for high-resolution and high-sensitivity small-animal PET imaging.
引用
收藏
页码:2713 / 2717
页数:5
相关论文
共 50 条
  • [41] Geant4-based Monte Carlo simulations on GPU for medical applications
    Bert, Julien
    Perez-Ponce, Hector
    El Bitar, Ziad
    Jan, Sebastien
    Boursier, Yannick
    Vintache, Damien
    Bonissent, Alain
    Morel, Christian
    Brasse, David
    Visvikis, Dimitris
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (16): : 5593 - 5611
  • [42] DICOM interface and visualization tool for Geant4-based dose calculation
    Kimura, A.
    Tanaka, S.
    Aso, T.
    Yoshida, H.
    Kanematsu, N.
    Asai, M.
    Sasaki, T.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 981 - 984
  • [43] GGEMS-brachy: fully GPU Geant4-based Monte Carlo simulation for brachytherapy applications
    Lemarechal, Y.
    Bert, J.
    Boussion, N.
    Visvikis, D.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S332 - S333
  • [44] DICOM data handling for Geant4-based medical physics application
    Kimura, A
    Aso, T
    Yoshida, H
    Kanematsu, N
    Tanaka, S
    Sasaki, T
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2124 - 2127
  • [45] GGEMS-Brachy: Fully GPU Geant4-Based Efficient Monte Carlo Simulation for Brachytherapy Applications
    Lemarechal, Y.
    Bert, J.
    Boussion, N.
    Pradier, O.
    Visvikis, D.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [46] Assessment of the spatial resolution of PET scanners using a Geant4-based Monte Carlo tool
    Fiedler, K
    Frach, T
    Rütten, W
    Solf, T
    Thon, A
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2549 - 2553
  • [47] Geant4-based calculation of electric field in deep dielectric charging
    Qin Xiao-Gang
    He De-Yan
    Wang Ji
    ACTA PHYSICA SINICA, 2009, 58 (01) : 684 - 689
  • [48] Development and validation of RAYDOSE: a Geant4-based application for molecular radiotherapy
    Marcatili, S.
    Pettinato, C.
    Daniels, S.
    Lewis, G.
    Edwards, P.
    Fanti, S.
    Spezi, E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (08): : 2491 - 2508
  • [49] Optical simulation of monolithic scintillator detectors using GATE/GEANT4
    van der Laan, D. J.
    Schaart, Dennis R.
    Maas, Marnix C.
    Beekman, Freek J.
    Bruyndonckx, Peter
    van Eijk, Carel W. E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (06): : 1659 - 1675
  • [50] GEANT4-based Monte Carlo Simulation of Beam Quality Correction Factors for the Leksell Gamma Knife® Perfexion
    Schaarschmidt, Thomas
    Kim, Tae Hoon
    Kim, Yong Kyun
    Yang, Hye Jeong
    Chung, Hyun-Tai
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2018, 73 (12) : 1814 - 1820