Geant4-based Monte Carlo simulations on GPU for medical applications

被引:66
|
作者
Bert, Julien [1 ]
Perez-Ponce, Hector [2 ]
El Bitar, Ziad [3 ]
Jan, Sebastien [4 ]
Boursier, Yannick [2 ]
Vintache, Damien [3 ]
Bonissent, Alain [2 ]
Morel, Christian [2 ]
Brasse, David [3 ]
Visvikis, Dimitris [1 ]
机构
[1] CHRU Brest, INSERM, UMR 1101, LaTIM, Brest, France
[2] Aix Marseille Univ, CPPM, CNRS, IN2P3, Marseille, France
[3] CNRS, IN2P3, UMR 7178, IPHC, Strasbourg, France
[4] Commissariat Energie Atom, SHFJ, I2BM, DSV, Orsay, France
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2013年 / 58卷 / 16期
关键词
PHOTON TRANSPORT; RECONSTRUCTION; IMPLEMENTATION; CT;
D O I
10.1088/0031-9155/58/16/5593
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Monte Carlo simulation (MCS) plays a key role in medical applications, especially for emission tomography and radiotherapy. However MCS is also associated with long calculation times that prevent its use in routine clinical practice. Recently, graphics processing units (GPU) became in many domains a low cost alternative for the acquisition of high computational power. The objective of this work was to develop an efficient framework for the implementation of MCS on GPU architectures. Geant4 was chosen as the MCS engine given the large variety of physics processes available for targeting different medical imaging and radiotherapy applications. In addition, Geant4 is the MCS engine behind GATE which is actually the most popular medical applications' simulation platform. We propose the definition of a global strategy and associated structures for such a GPU based simulation implementation. Different photon and electron physics effects are resolved on the fly directly on GPU without any approximations with respect to Geant4. Validations have shown equivalence in the underlying photon and electron physics processes between the Geant4 and the GPU codes with a speedup factor of 80-90. More clinically realistic simulations in emission and transmission imaging led to acceleration factors of 400-800 respectively compared to corresponding GATE simulations.
引用
收藏
页码:5593 / 5611
页数:19
相关论文
共 50 条
  • [1] GPU-acceleration of GEANT4-based Monte Carlo simulations for radio therapy
    Jahnke, L. K. R.
    Fleckenstein, J.
    Clausen, S.
    Hesser, J.
    Lohr, F.
    Wenz, F.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S628 - S628
  • [2] GGEMS-Brachy: GPU GEant4-based Monte Carlo simulation for brachytherapy applications
    Lemarechal, Yannick
    Bert, Julien
    Falconnet, Claire
    Despres, Philippe
    Valeri, Antoine
    Schick, Ulrike
    Pradier, Olivier
    Garcia, Marie-Paule
    Boussion, Nicolas
    Visvikis, Dimitris
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (13): : 4987 - 5006
  • [3] GGEMS-brachy: fully GPU Geant4-based Monte Carlo simulation for brachytherapy applications
    Lemarechal, Y.
    Bert, J.
    Boussion, N.
    Visvikis, D.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S332 - S333
  • [4] GGEMS-Brachy: Fully GPU Geant4-Based Efficient Monte Carlo Simulation for Brachytherapy Applications
    Lemarechal, Y.
    Bert, J.
    Boussion, N.
    Pradier, O.
    Visvikis, D.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [5] Development and verification of Geant4-based parallel computing Monte Carlo simulations for nuclear logging applications
    Wang, Yang
    Liang, Jingang
    Zhang, Qiong
    Wang, Xinyang
    Tang, Wei
    Chen, Ye
    [J]. ANNALS OF NUCLEAR ENERGY, 2022, 172
  • [6] A Geant4-based Monte Carlo Tool for Nuclear Astrophysics
    Lattuada, D.
    La Cognata, M.
    Anzalone, A.
    Balabanski, D. L.
    Chesnevskaya, S.
    Costa, M.
    Crucilla, V.
    Guardo, G. L.
    Gulino, M.
    Matei, C.
    Pizzone, R. G.
    Romano, S.
    Spitaleri, C.
    Tumino, A.
    Xu, Y.
    [J]. 9TH EUROPEAN SUMMER SCHOOL ON EXPERIMENTAL NUCLEAR ASTROPHYSICS, 2018, 184
  • [7] Geant4-based Monte Carlo simulation of the Leksell Gamma Knife®
    Romano, F.
    Sabini, M. G.
    Cuttone, G.
    Russo, G.
    Mongelli, V.
    Foroni, R.
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2581 - +
  • [8] Study of CdTe detection efficiency for medical applications using Geant4-based stochastic simulations
    Basit, Abdul
    Siddique, M. Tariq
    Mirza, Sikander M.
    Rehman, Shakeel Ur
    Hamza, M. Y.
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2018, 38 (04) : 1483 - 1500
  • [9] A Visualization Tool for Geant4-Based Medical Physics Applications
    Kimura, Akinori
    Tanaka, Satoshi
    Saitoh, Ayumu
    Sasaki, Takashi
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 793 - 795
  • [10] Radiobiological quantities in proton-therapy: Estimation and validation using Geant4-based Monte Carlo simulations
    Petringa, G.
    Romano, F.
    Manti, L.
    Pandola, L.
    Attili, A.
    Cammarata, F.
    Cuttone, G.
    Forte, G.
    Manganaro, L.
    Pipek, J.
    Pisciotta, P.
    Russo, G.
    Cirrone, G. A. P.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 58 : 72 - 80