GATE: A Geant4-based simulation platform for PET and SPECT integrating movement and time management

被引:161
|
作者
Santin, G [1 ]
Strul, D
Lazaro, D
Simon, L
Krieguer, M
Martins, MV
Breton, V
Morel, C
机构
[1] European Space Agcy, Estec, NL-2200 AG Noordwijk, Netherlands
[2] Univ Lausanne, Inst High Energy Phys, CH-1015 Lausanne, Switzerland
[3] Univ Clermont Ferrand, Phys Corpusculaire Lab, CNRS, IN2P3, F-63177 Clermont Ferrand, France
[4] Free Univ Brussels, Inter Inst High Energy, B-1050 Brussels, Belgium
[5] Univ Lisbon, Inst Biophys & Biomed Engn, P-1700 Lisbon, Portugal
关键词
Geant4; Geant4 application for tomographic emission; gamma cameras; Monte Carlo simulations; positron emission tomography (PET);
D O I
10.1109/TNS.2003.817974
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
GATE, the Geant4 application for tomographic emission, is a simulation platform developed for PET and SPECT. It combines a powerful simulation core, the Geant4 toolkit, with newly developed software components dedicated to nuclear medicine. In particular, it models the passing of time during real acquisitions, allowing it to handle dynamic systems such as decaying source distributions or moving detectors. We present several series of results that illustrate the possibilities of this new platform. The simulation of decaying sources is illustrated on a dual-isotope acquisition with multiple time-frames. Count rate curves taking into account random coincidences and dead-time are shown for a dual-crystal setup and for a small-animal PET scanner configuration. Simulated resolution curves and reconstructed images are shown for rotating PET scanners. Lastly, we present first comparisons of simulated point-spread functions and spectra with experimental results obtained from a small-animal gamma camera prototype.
引用
收藏
页码:1516 / 1521
页数:6
相关论文
共 50 条
  • [1] GATE, a Geant4-based simulation platform for PET integrating movement and time management
    Santin, G
    Strul, D
    Lazaro, D
    Simon, L
    Krieguer, M
    Martins, MV
    Breton, V
    Morel, C
    [J]. 2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1325 - 1329
  • [2] The Geant4-based BABAR simulation
    Wright, D
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 499 - 502
  • [3] Investigation of OPET performance using GATE, a Geant4-based simulation software
    Rannou, F
    Kohli, V
    Prout, D
    Chatziioannou, A
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2048 - 2052
  • [4] Investigation of OPET performance using GATE, a Geant4-based simulation software
    Rannou, FR
    Kohli, V
    Prout, DL
    Chatziioannou, AF
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2713 - 2717
  • [5] GATE (Geant4 Application for Tomographic Emission): a PET/SPECT general-purpose simulation platform
    Strul, D
    Santin, G
    Lazaro, D
    Breton, V
    Morel, C
    [J]. NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2003, 125 : 75 - 79
  • [6] Validation of Geant4-Based Radioactive Decay Simulation
    Hauf, Steffen
    Kuster, Markus
    Batic, Matej
    Bell, Zane W.
    Hoffmann, Dieter H. H.
    Lang, Philipp M.
    Neff, Stephan
    Pia, Maria Grazia
    Weidenspointner, Georg
    Zoglauer, Andreas
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (04) : 2984 - 2997
  • [7] A Geant4-based Monte Carlo X-ray imaging simulation platform
    Li, Ouyi
    Gao, Jianhua
    Zhang, Qiong
    [J]. APPLIED RADIATION AND ISOTOPES, 2024, 210
  • [8] The Geant4-Based Simulation Software of the ATLAS Detector
    Costanzo, D.
    Dell'Acqua, A.
    Gallas, M.
    Rimoldi, A.
    Boudreau, J.
    Tsulaia, V.
    Di Simone, A.
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 5 - 11
  • [9] Validation of a small-animal PET simulation using GAMOS: a GEANT4-based framework
    Canadas, M.
    Arce, P.
    Rato Mendes, P.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (01): : 273 - 288
  • [10] GATE as a GEANT4-based Monte Carlo platform for the evaluation of proton pencil beam scanning treatment plans
    Grevillot, L.
    Bertrand, D.
    Dessy, F.
    Freud, N.
    Sarrut, D.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (13): : 4223 - 4244