A combined Optical Positron Emission Tomography (OPET) system is capable of both optical and PET imaging in the same setting and it can provide information/interpretation not possible in single mode imaging. The scintillator array here serves the dual function of coupling the optical signal from bioluminescence/fluorescence to the photodetector and also of channeling optical scintillations from the gamma rays. Here we report simulation results of the PET part of OPET using GATE, a Geant4 simulation package. The purpose of this investigation is the definition of the geometric parameters of the OPET tomograph. OPET is composed of six detector blocks arranged in a hexagonal ring shaped pattern with an inner radius of 15.4 mm. Each detector consists of a 2D array of 8x8 scintillator crystals each measuring 2x2x10 mm(3). Monte Carlo simulations were performed using the GATE software to measure absolute sensitivity, depth of interaction, and spatial resolution for two ring configurations, with and without gantry rotations, two crystal materials, and several crystal lengths. Images were reconstructed with Filtered Backprojection after angular interleaving and transverse ID interpolation of the sinogram. We report absolute sensitivities nearly seven times that of the prototype microPET at the center of FOV and averages of 2.0 mm tangential and 2.3 mm radial resolutions with gantry rotations up to an 8.0 mm offset. These performance parameters indicate that the imaging spatial resolution and sensitivity of the OPET system will be suitable for high resolution and high sensitivity small animal PET imaging.
引用
收藏
页码:2048 / 2052
页数:5
相关论文
共 50 条
  • [1] Investigation of OPET performance using GATE, a Geant4-based simulation software
    Rannou, FR
    Kohli, V
    Prout, DL
    Chatziioannou, AF
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2713 - 2717
  • [2] The Geant4-Based Simulation Software of the ATLAS Detector
    Costanzo, D.
    Dell'Acqua, A.
    Gallas, M.
    Rimoldi, A.
    Boudreau, J.
    Tsulaia, V.
    Di Simone, A.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 5 - 11
  • [3] The Geant4-based BABAR simulation
    Wright, D
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 499 - 502
  • [4] GATE, a Geant4-based simulation platform for PET integrating movement and time management
    Santin, G
    Strul, D
    Lazaro, D
    Simon, L
    Krieguer, M
    Martins, MV
    Breton, V
    Morel, C
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1325 - 1329
  • [5] Validation of Geant4-Based Radioactive Decay Simulation
    Hauf, Steffen
    Kuster, Markus
    Batic, Matej
    Bell, Zane W.
    Hoffmann, Dieter H. H.
    Lang, Philipp M.
    Neff, Stephan
    Pia, Maria Grazia
    Weidenspointner, Georg
    Zoglauer, Andreas
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (04) : 2984 - 2997
  • [6] Geant4-based multiphysics simulation toolkit for analysis of radiation detector performance
    Guckes, Amber L.
    Green, J. Andrew
    Smalley, Duane D.
    Martin, Matthew A.
    Baker, Stuart A.
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XXI, 2019, 11114
  • [7] GATE: A Geant4-based simulation platform for PET and SPECT integrating movement and time management
    Santin, G
    Strul, D
    Lazaro, D
    Simon, L
    Krieguer, M
    Martins, MV
    Breton, V
    Morel, C
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) : 1516 - 1521
  • [8] An investigation of neutron weighting factors using a Geant4-based microdosimetry pipeline
    Lund, Christopher
    Famulari, Gabriel
    Montgomery, Logan
    Kildea, John
    MEDICAL PHYSICS, 2019, 46 (11) : 5391 - 5391
  • [9] Geant4-based simulation of a beam radiation monitor for SUPERB
    Cardarelli, R.
    Di Ciaccio, A.
    Di Simone, A.
    Tammaro, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 718 : 200 - 201
  • [10] MULASSIS: A Geant4-based multilayered shielding simulation tool
    Lei, F
    Truscott, PR
    Dyer, CS
    Quaghebeur, B
    Heynderickx, D
    Nieminen, P
    Evans, H
    Daly, E
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (06) : 2788 - 2793