Investigation of OPET performance using GATE, a Geant4-based simulation software

被引:0
|
作者
Rannou, F [1 ]
Kohli, V [1 ]
Prout, D [1 ]
Chatziioannou, A [1 ]
机构
[1] Univ Calif Los Angeles, Crump Inst Mol Imaging, Dept Mol & Med Pharmacol, David Geffen Sch Med, Los Angeles, CA 90095 USA
关键词
GATE; optical; PET;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A combined Optical Positron Emission Tomography (OPET) system is capable of both optical and PET imaging in the same setting and it can provide information/interpretation not possible in single mode imaging. The scintillator array here serves the dual function of coupling the optical signal from bioluminescence/fluorescence to the photodetector and also of channeling optical scintillations from the gamma rays. Here we report simulation results of the PET part of OPET using GATE, a Geant4 simulation package. The purpose of this investigation is the definition of the geometric parameters of the OPET tomograph. OPET is composed of six detector blocks arranged in a hexagonal ring shaped pattern with an inner radius of 15.4 mm. Each detector consists of a 2D array of 8x8 scintillator crystals each measuring 2x2x10 mm(3). Monte Carlo simulations were performed using the GATE software to measure absolute sensitivity, depth of interaction, and spatial resolution for two ring configurations, with and without gantry rotations, two crystal materials, and several crystal lengths. Images were reconstructed with Filtered Backprojection after angular interleaving and transverse ID interpolation of the sinogram. We report absolute sensitivities nearly seven times that of the prototype microPET at the center of FOV and averages of 2.0 mm tangential and 2.3 mm radial resolutions with gantry rotations up to an 8.0 mm offset. These performance parameters indicate that the imaging spatial resolution and sensitivity of the OPET system will be suitable for high resolution and high sensitivity small animal PET imaging.
引用
收藏
页码:2048 / 2052
页数:5
相关论文
共 50 条
  • [21] A GEANT4-based simulation model for the BESIII endcap time-of-flight system
    Liu, Y.
    Deng, Z. Y.
    Liu, H. M.
    Sun, S. S.
    Tian, H. L.
    Wang, Y. F.
    Zhang, X. J.
    Zhao, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 629 (01): : 87 - 92
  • [22] A Geant4-based Monte Carlo X-ray imaging simulation platform
    Li, Ouyi
    Gao, Jianhua
    Zhang, Qiong
    APPLIED RADIATION AND ISOTOPES, 2024, 210
  • [23] GEANT4-based calibration of an organic liquid scintillator
    Mauritzson, N.
    Fissum, K. G.
    Perrey, H.
    Annand, J. R. M.
    Frost, R. J. W.
    Hall-Wilton, R.
    Al Jebali, R.
    Kanaki, K.
    Maulerova-Subert, V
    Messi, F.
    Rofors, E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1023
  • [24] G4-STORK: A Geant4-based Monte Carlo reactor kinetics simulation code
    Russell, Liam
    Buijs, Adriaan
    Jonkmans, Guy
    ANNALS OF NUCLEAR ENERGY, 2014, 71 : 451 - 461
  • [25] A Geant4-based simulation of an accelerator's head used for intensity modulated radiation therapy
    Foppiano, F
    Mascialino, B
    Pia, MG
    Piergentili, M
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2128 - 2132
  • [26] GGEMS-Brachy: GPU GEant4-based Monte Carlo simulation for brachytherapy applications
    Lemarechal, Yannick
    Bert, Julien
    Falconnet, Claire
    Despres, Philippe
    Valeri, Antoine
    Schick, Ulrike
    Pradier, Olivier
    Garcia, Marie-Paule
    Boussion, Nicolas
    Visvikis, Dimitris
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (13): : 4987 - 5006
  • [27] GATE as a GEANT4-based Monte Carlo platform for the evaluation of proton pencil beam scanning treatment plans
    Grevillot, L.
    Bertrand, D.
    Dessy, F.
    Freud, N.
    Sarrut, D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (13): : 4223 - 4244
  • [28] First GEANT4-based simulation investigation of a Li-coated resistive plate chamber for low-energy neutrons
    Rhee, J. T.
    Jamil, M.
    Jeon, Y. J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 718 : 237 - 239
  • [29] A Visualization Tool for Geant4-Based Medical Physics Applications
    Kimura, Akinori
    Tanaka, Satoshi
    Saitoh, Ayumu
    Sasaki, Takashi
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 793 - 795
  • [30] GXPS: A Geant4-based Monte Carlo code for x-ray polycapillary simulation
    Chi, Zhijun
    JOURNAL OF APPLIED PHYSICS, 2020, 128 (12)