Detection of a novel glycodelin biomarker using electrochemical immunosensor for endometriosis

被引:23
|
作者
Kalyani, Thangapandi [1 ]
Nanda, Amalesh [1 ]
Jana, Saikat Kumar [1 ]
机构
[1] Natl Inst Technol, Dept Biotechnol, Papum Pare 791112, Arunachal Prade, India
关键词
Endometriosis; Glycodelin; Immunosensor; Cysteamine; Label-free; SQUARE-WAVE; LABEL; ANTIGEN; CA-125; SERUM; ELECTRODES; ANTIBODIES; SENSOR; WOMEN;
D O I
10.1016/j.aca.2020.11.015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Endometriosis is one of the important issues in women worldwide, which decreases the quality of women's lives in their reproductive age. The diagnosis of endometriosis is carried out by the invasive procedure, which is expensive and painful. In the last few decades, researchers have given more attention to constructing a suitable biomarker-based biosensor for semi/non-invasive diagnosis of endometriosis. As a result, glycodelin (GLY) was found as a promising biomarker because of its selectivity and sensitivity. To the best of our knowledge, it was the first study that reported the detection of GLY biomarker using an electrochemical immunosensor. Briefly, a label-free electrochemical immunosensing platform was constructed through in-situ surface modification of cysteamine layer and immobilisation of antibody (anti-GLY) with help of glutaraldehyde. The interaction between antigen and antibody was measured using square wave voltammetry (SWV). The SWV signal could decrease proportionally with the increasing GLY concentration ranging from 1 to 1000 ng mL(-1) (R-2 = 0.9981) and a detection limit (LOD) of 0.43 ng mL(-1). Moreover, an immunosensor could exhibit high sensitivity, selectivity, long-term stability, reproducibility and regeneration. Accuracy of the immunosensor was compared with enzyme-linked immunosorbent assay (ELISA), and satisfying results were obtained. The detection of GLY biomarker may be a new possibility for endometriosis diagnosis. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页码:146 / 154
页数:9
相关论文
共 50 条
  • [31] An Immunosensor for the Detection of ULBP2 Biomarker
    Yang, Wen-Chi
    Liao, Su-Yu
    Phan, Thien Luan
    Van Hieu, Nguyen
    Chu, Pei-Yi
    Yi, Chin-Chang
    Wu, Hsing-Ju
    Chang, Kang-Ming
    Ching, Congo Tak-Shing
    MICROMACHINES, 2020, 11 (06)
  • [32] Earlier Detection of Alzheimer's Disease Based on a Novel Biomarker cis P-tau by a Label-Free Electrochemical Immunosensor
    Shiravandi, Ayoub
    Yari, Farzaneh
    Tofigh, Nahid
    Ashtiani, Mohammad Kazemi
    Shahpasand, Koorosh
    Ghanian, Mohammad-Hossein
    Shekari, Faezeh
    Faridbod, Farnoush
    BIOSENSORS-BASEL, 2022, 12 (10):
  • [33] Electrochemical immunosensor for detection of Francisella tularensis
    Skladal, P
    Symerska, Y
    Pohanka, M
    Safar, B
    Macela, A
    Defense Against Bioterror: Detection Technologies, Implementation Strategies and Commercial Opportunities, 2005, 1 : 221 - 232
  • [34] Ultrasensitive detection of NSE employing a novel electrochemical immunosensor based on a conjugated copolymer
    Aydin, Muhammet
    Aydin, Elif Burcu
    Sezginturk, Mustafa Kemal
    ANALYST, 2024, 149 (05) : 1632 - 1644
  • [35] A novel electrochemical immunosensor based on magnetosomes for detection of staphylococcal enterotoxin B in milk
    Wu, Longyun
    Gao, Bo
    Zhang, Fang
    Sun, Xiulan
    Zhang, Yinzhi
    Li, Zaijun
    TALANTA, 2013, 106 : 360 - 366
  • [36] A novel electrochemical immunosensor for ultrasensitive detection of CA125 in ovarian cancer
    Pakchin, Parvin Samadi
    Fathi, Marziyeh
    Ghanbari, Hossein
    Saber, Reza
    Omidi, Yadollah
    BIOSENSORS & BIOELECTRONICS, 2020, 153
  • [37] Novel sensitive immunosensor for the selective detection of Engrailed 2 urinary prostate cancer biomarker
    Mokni, Meriem
    Tlili, Amal
    Attia, Ghada
    Khaoulani, Sohayb
    Zerrouki, Chouki
    Omezzine, Asma
    Othmane, Ali
    Bouslama, Ali
    Fourati, Najla
    BIOSENSORS & BIOELECTRONICS, 2022, 217
  • [38] The detection of papaya ringspot virus coat protein using an electrochemical immunosensor
    Valekunja, Rohini Bhat
    Kamakoti, Vikramshankar
    Peter, Anitha
    Phadnis, Shamprasad
    Prasad, Shalini
    Nagaraj, Vinay J.
    Analytical Methods, 2016, 8 (48) : 8534 - 8541
  • [39] Polychlorinated biphenyls (PCBs) detection in food samples using an electrochemical immunosensor
    Laschi, S
    Mascini, M
    Scortichini, G
    Fránek, M
    Mascini, M
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2003, 51 (07) : 1816 - 1822
  • [40] Rapid SARS-CoV-2 Detection Using Electrochemical Immunosensor
    Mojsoska, Biljana
    Larsen, Sylvester
    Olsen, Dorte Aalund
    Madsen, Jonna Skov
    Brandslund, Ivan
    Alatraktchi, Fatima AlZahra'a
    SENSORS, 2021, 21 (02) : 1 - 11