A novel electrochemical immunosensor based on magnetosomes for detection of staphylococcal enterotoxin B in milk

被引:37
|
作者
Wu, Longyun [1 ]
Gao, Bo [1 ]
Zhang, Fang [1 ]
Sun, Xiulan [1 ]
Zhang, Yinzhi [1 ]
Li, Zaijun [1 ,2 ]
机构
[1] Jiangnan Univ, Sch Food Sci, State Key Lab Food Sci & Technol, Wuxi 214122, Jiangsu, Peoples R China
[2] Jiangnan Univ, Sch Chem & Mat Engn, Wuxi 214122, Jiangsu, Peoples R China
关键词
Polyaniline nano-gold composite; Magnetosomes; Electrochemical immunosensor; Staphylococcal enterotoxin B; MAGNETIC BEADS; DAIRY-PRODUCTS; NANOPARTICLES; ANTIBODY; IMMUNOASSAY; ELECTRODE; ANTIGEN; SYSTEM; LIQUID; VIRUS;
D O I
10.1016/j.talanta.2012.12.053
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, a novel electrochemical immunosensor to detect staphylococcal enterotoxin B based on bio-magnetosomes, polyaniline nano-gold composite and 1,2-dimethyl-3-butylimidazolium hexafluorphosphate ionic liquid, was developed, and found to exhibit high sensitivity and stability. The specific antibody to staphylococcal enterotoxin B conjugated with the magnetosomes showed rapid immunoreactions and good dispersion, which contributed to the formation of a nanostructurally smooth and dense film on the surface of a gold electrode. Polyaniline nano-gold composite and 1,2-dimethyl-3-butylimidazolium hexafluorophosphate ionic liquid were used to modify the electrode as mediators to improve the electron transfer and offer an excellent biocompatible microenvironment for the antibody to retain its activity to enhance the response of the electrochemical sensor. Under optimal conditions, the developed immunosensor showed a good linear response in the range from 0.05 to 5 ng/mL (R-2=0.9957) with a detection limit as low as 0.017 ng/mL, compared with the one without magnetosomes (0.05-5 ng/mL, 0.033 ng/mL), this developed immunosensor showed a wider response range and a reduced detection limit. And a good specificity with little adsorption to staphylococcal enterotoxin A, C and Na+, K+, Ca2+ was obtained. Moreover, the immunosensor exhibited a good long-time stability at 4 degrees C reaching up to 60 days, which showed a relatively long working life. Meanwhile the immunosensor could be regenerated four times using NaOH elution. The sensor also displayed a good repeatability with a relative standard deviation of 5.02% for staphylococcal enterotoxin B detection (1 ng/mL, n=9). Furthermore, high recoveries in milk samples from 81% to 118% were achieved and successfully applied to milk sample detection. The obtained results demonstrate that the developed electrochemical immunosensor is a promising tool for the detection of staphylococcal enterotoxin B in food. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:360 / 366
页数:7
相关论文
共 50 条
  • [1] Piezoelectric crystal immunosensor for the detection of staphylococcal enterotoxin B
    Lin, HC
    Tsai, WC
    BIOSENSORS & BIOELECTRONICS, 2003, 18 (12): : 1479 - 1483
  • [2] Electrochemical immunosensor for the detection of staphylococcal enterotoxin B using screen-printed electrodes
    Sharma, Arun
    Rao, Vepa Kameswara
    Kamboj, Dev Vrat
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 2020, 59 (02): : 174 - 180
  • [3] An aptamer-based electrochemical biosensor for simple and sensitive detection of staphylococcal enterotoxin B in milk
    Xiong, Xiaohui
    Shi, Xinping
    Liu, Yuanjian
    Lu, Lixia
    You, Jingjing
    ANALYTICAL METHODS, 2018, 10 (03) : 365 - 370
  • [4] A staphylococcal enterotoxin B magnetoelastic immunosensor
    Ruan, CM
    Zeng, KF
    Varghese, OK
    Grimes, CA
    BIOSENSORS & BIOELECTRONICS, 2004, 20 (03): : 585 - 591
  • [5] Detection of Staphylococcal Enterotoxin B employing a piezoelectric crystal immunosensor
    Harteveld, JLN
    Nieuwenhuizen, MS
    Wils, ERJ
    BIOSENSORS & BIOELECTRONICS, 1997, 12 (07): : 661 - 667
  • [6] Elaboration of a reusable immunosensor for the detection of staphylococcal enterotoxin A (SEA) in milk with a quartz crystal microbalance
    Salmain, Michele
    Ghasemi, Mahsa
    Boujday, Souhir
    Pradier, Claire-Marie
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 173 : 148 - 156
  • [7] An ultrasensitive immunosensor array for determination of staphylococcal enterotoxin B
    Zhang, Xiaoming
    Liu, Fei
    Yan, Ruifang
    Xue, Pan
    Li, Yongming
    Chen, Lili
    Song, Chaojun
    Liu, Cui
    Jin, Boquan
    Zhang, Zhujun
    Yang, Kun
    TALANTA, 2011, 85 (02) : 1070 - 1074
  • [8] Gold nanoparticle-based enhanced chemiluminescence immunosensor for detection of Staphylococcal Enterotoxin B (SEB) in food
    Yang, Minghui
    Kostov, Yordan
    Bruck, Hugh A.
    Rasooly, Avraham
    INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2009, 133 (03) : 265 - 271
  • [9] DETECTION OF STAPHYLOCOCCAL ENTEROTOXIN-A, ENTEROTOXIN-B, AND ENTEROTOXIN-C IN MILK BY AN ELISA PROCEDURE
    OLSVIK, O
    MYHRE, S
    BERDAL, BP
    FOSSUM, K
    ACTA VETERINARIA SCANDINAVICA, 1982, 23 (02) : 204 - 210
  • [10] Electrochemical aptasensor for sensitive detection of staphylococcal enterotoxin type A in milk and fruit juice
    Singh, Smriti
    Agrawal, Ravi Kant
    Nara, Seema
    MICROCHIMICA ACTA, 2024, 191 (10)