A novel electrochemical immunosensor based on magnetosomes for detection of staphylococcal enterotoxin B in milk

被引:37
|
作者
Wu, Longyun [1 ]
Gao, Bo [1 ]
Zhang, Fang [1 ]
Sun, Xiulan [1 ]
Zhang, Yinzhi [1 ]
Li, Zaijun [1 ,2 ]
机构
[1] Jiangnan Univ, Sch Food Sci, State Key Lab Food Sci & Technol, Wuxi 214122, Jiangsu, Peoples R China
[2] Jiangnan Univ, Sch Chem & Mat Engn, Wuxi 214122, Jiangsu, Peoples R China
关键词
Polyaniline nano-gold composite; Magnetosomes; Electrochemical immunosensor; Staphylococcal enterotoxin B; MAGNETIC BEADS; DAIRY-PRODUCTS; NANOPARTICLES; ANTIBODY; IMMUNOASSAY; ELECTRODE; ANTIGEN; SYSTEM; LIQUID; VIRUS;
D O I
10.1016/j.talanta.2012.12.053
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, a novel electrochemical immunosensor to detect staphylococcal enterotoxin B based on bio-magnetosomes, polyaniline nano-gold composite and 1,2-dimethyl-3-butylimidazolium hexafluorphosphate ionic liquid, was developed, and found to exhibit high sensitivity and stability. The specific antibody to staphylococcal enterotoxin B conjugated with the magnetosomes showed rapid immunoreactions and good dispersion, which contributed to the formation of a nanostructurally smooth and dense film on the surface of a gold electrode. Polyaniline nano-gold composite and 1,2-dimethyl-3-butylimidazolium hexafluorophosphate ionic liquid were used to modify the electrode as mediators to improve the electron transfer and offer an excellent biocompatible microenvironment for the antibody to retain its activity to enhance the response of the electrochemical sensor. Under optimal conditions, the developed immunosensor showed a good linear response in the range from 0.05 to 5 ng/mL (R-2=0.9957) with a detection limit as low as 0.017 ng/mL, compared with the one without magnetosomes (0.05-5 ng/mL, 0.033 ng/mL), this developed immunosensor showed a wider response range and a reduced detection limit. And a good specificity with little adsorption to staphylococcal enterotoxin A, C and Na+, K+, Ca2+ was obtained. Moreover, the immunosensor exhibited a good long-time stability at 4 degrees C reaching up to 60 days, which showed a relatively long working life. Meanwhile the immunosensor could be regenerated four times using NaOH elution. The sensor also displayed a good repeatability with a relative standard deviation of 5.02% for staphylococcal enterotoxin B detection (1 ng/mL, n=9). Furthermore, high recoveries in milk samples from 81% to 118% were achieved and successfully applied to milk sample detection. The obtained results demonstrate that the developed electrochemical immunosensor is a promising tool for the detection of staphylococcal enterotoxin B in food. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:360 / 366
页数:7
相关论文
共 50 条
  • [31] Reduced Graphene Oxide-Based Impedimetric Immunosensor for Detection of Enterotoxin A in Milk Samples
    Rocha, Giovanna S.
    Silva, Martin K. L.
    Cesarino, Ivana
    MATERIALS, 2020, 13 (07)
  • [33] Piezoelectric immunosensor for direct and rapid detection of staphylococcal enterotoxin A (SEA) at the ng level
    Salmain, Michele
    Ghasemi, Mahsa
    Boujday, Souhir
    Spadavecchia, Jolanda
    Techer, Clarisse
    Val, Florence
    Le Moigne, Vincent
    Gautier, Michel
    Briandet, Romain
    Pradier, Claire-Marie
    BIOSENSORS & BIOELECTRONICS, 2011, 29 (01): : 140 - 144
  • [35] Detection of staphylococcal enterotoxin C2 employing a piezoelectric crystal immunosensor
    Gao, ZX
    Chao, FH
    Chao, Z
    Li, GX
    SENSORS AND ACTUATORS B-CHEMICAL, 2000, 66 (1-3) : 193 - 196
  • [36] Multiplexed Electrochemical Detection of Yersinia Pestis and Staphylococcal Enterotoxin B using an Antibody Microarray
    Wojciechowski, Jason
    Danley, David
    Cooper, John
    Yazvenko, Nina
    Taitt, Chris Rowe
    SENSORS, 2010, 10 (04): : 3351 - 3362
  • [37] Nano-biotechnological approach for the ultrasensitive electrochemical and fluorescence detection of Staphylococcal enterotoxin B
    Meenakshi, Saish
    Pawar, Saish
    Shivhare, Brijesh
    Sharma, Arun
    Prabhu, Sudharshan
    Awasthi, Shikha
    MATERIALS RESEARCH EXPRESS, 2025, 12 (03)
  • [38] An electrochemical aptasensor for staphylococcal enterotoxin B detection based on reduced graphene oxide and gold nano-urchins
    Nodoushan, Somayeh Mousavi
    Nasirizadeh, Navid
    Amani, Jafar
    Halabian, Raheleh
    Fooladi, Abbas Ali Imani
    BIOSENSORS & BIOELECTRONICS, 2019, 127 : 221 - 228
  • [39] A novel metal-organic framework based electrochemical immunosensor for the rapid detection of Salmonella typhimurium detection in milk
    Zhan, Ke
    Chen, Linlin
    Li, Shanshan
    Yu, Qiuying
    Zhao, Zheng
    Li, Junwei
    Xing, Yunrui
    Ren, Hongtao
    Wang, Na
    Zhang, Gaiping
    FOOD CHEMISTRY, 2024, 444
  • [40] Electrochemical immunosensor detection for lactoferrin in milk powder
    Huang, Junyi
    He, Ziyu
    Cao, Jie
    Hong, Jiang
    Wu, Zhengjun
    Gao, Haiyan
    Liao, Xianyan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (08): : 7816 - 7826