A novel electrochemical immunosensor based on magnetosomes for detection of staphylococcal enterotoxin B in milk

被引:37
|
作者
Wu, Longyun [1 ]
Gao, Bo [1 ]
Zhang, Fang [1 ]
Sun, Xiulan [1 ]
Zhang, Yinzhi [1 ]
Li, Zaijun [1 ,2 ]
机构
[1] Jiangnan Univ, Sch Food Sci, State Key Lab Food Sci & Technol, Wuxi 214122, Jiangsu, Peoples R China
[2] Jiangnan Univ, Sch Chem & Mat Engn, Wuxi 214122, Jiangsu, Peoples R China
关键词
Polyaniline nano-gold composite; Magnetosomes; Electrochemical immunosensor; Staphylococcal enterotoxin B; MAGNETIC BEADS; DAIRY-PRODUCTS; NANOPARTICLES; ANTIBODY; IMMUNOASSAY; ELECTRODE; ANTIGEN; SYSTEM; LIQUID; VIRUS;
D O I
10.1016/j.talanta.2012.12.053
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, a novel electrochemical immunosensor to detect staphylococcal enterotoxin B based on bio-magnetosomes, polyaniline nano-gold composite and 1,2-dimethyl-3-butylimidazolium hexafluorphosphate ionic liquid, was developed, and found to exhibit high sensitivity and stability. The specific antibody to staphylococcal enterotoxin B conjugated with the magnetosomes showed rapid immunoreactions and good dispersion, which contributed to the formation of a nanostructurally smooth and dense film on the surface of a gold electrode. Polyaniline nano-gold composite and 1,2-dimethyl-3-butylimidazolium hexafluorophosphate ionic liquid were used to modify the electrode as mediators to improve the electron transfer and offer an excellent biocompatible microenvironment for the antibody to retain its activity to enhance the response of the electrochemical sensor. Under optimal conditions, the developed immunosensor showed a good linear response in the range from 0.05 to 5 ng/mL (R-2=0.9957) with a detection limit as low as 0.017 ng/mL, compared with the one without magnetosomes (0.05-5 ng/mL, 0.033 ng/mL), this developed immunosensor showed a wider response range and a reduced detection limit. And a good specificity with little adsorption to staphylococcal enterotoxin A, C and Na+, K+, Ca2+ was obtained. Moreover, the immunosensor exhibited a good long-time stability at 4 degrees C reaching up to 60 days, which showed a relatively long working life. Meanwhile the immunosensor could be regenerated four times using NaOH elution. The sensor also displayed a good repeatability with a relative standard deviation of 5.02% for staphylococcal enterotoxin B detection (1 ng/mL, n=9). Furthermore, high recoveries in milk samples from 81% to 118% were achieved and successfully applied to milk sample detection. The obtained results demonstrate that the developed electrochemical immunosensor is a promising tool for the detection of staphylococcal enterotoxin B in food. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:360 / 366
页数:7
相关论文
共 50 条
  • [21] Rapid detection of staphylococcal enterotoxin B in milk samples based on fluorescence hybridization chain reaction amplification
    Xu, Yanyang
    Huo, Bingyang
    Sun, Xuan
    Ning, Baoan
    Peng, Yuan
    Bai, Jialei
    Gao, Zhixian
    RSC ADVANCES, 2018, 8 (29): : 16024 - 16031
  • [22] Reagentless detection of staphylococcal enterotoxin B via electrochemical interrogation of conformational changes
    Wang, Xiaohong
    Da, Jianping
    Liu, Yuanjian
    CHIRALITY, 2022, 34 (09) : 1219 - 1227
  • [23] Detection of staphylococcal enterotoxin in pasteurized milk with ELISA technique
    Küplülü, Ö
    Sarimehmetoglu, B
    Kaymaz, S
    TURKISH JOURNAL OF VETERINARY & ANIMAL SCIENCES, 2002, 26 (03): : 631 - 637
  • [24] Gold nanoparticle-based localized surface plasmon immunosensor for staphylococcal enterotoxin A (SEA) detection
    Ben Haddada, Maroua
    Hu, David
    Salmain, Michele
    Zhang, Lu
    Peng, Chen
    Wang, Yi
    Liedberg, Bo
    Boujday, Souhir
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (26) : 6227 - 6234
  • [25] Gold nanoparticle-based localized surface plasmon immunosensor for staphylococcal enterotoxin A (SEA) detection
    Maroua Ben Haddada
    David Hu
    Michèle Salmain
    Lu Zhang
    Chen Peng
    Yi Wang
    Bo Liedberg
    Souhir Boujday
    Analytical and Bioanalytical Chemistry, 2017, 409 : 6227 - 6234
  • [26] Electrochemical Immunosensor for Staphylococcal Enterotoxin B (SEB) Based on Platinum Nanoparticles-Modified Electrode Using Hydrogen Evolution Inhibition Approach
    Sharma, Arun
    Rao, Vepa Kameswara
    Kamboj, Dev Vrat
    Jain, Rajeev
    ELECTROANALYSIS, 2014, 26 (11) : 2320 - 2327
  • [27] A capacitive biosensor for detection of staphylococcal enterotoxin B
    Mahmoud Labib
    Martin Hedström
    Magdy Amin
    Bo Mattiasson
    Analytical and Bioanalytical Chemistry, 2009, 393
  • [28] A capacitive biosensor for detection of staphylococcal enterotoxin B
    Labib, Mahmoud
    Hedstroem, Martin
    Amin, Magdy
    Mattiasson, Bo
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (05) : 1539 - 1544
  • [29] Novel chemiluminescent assay for staphylococcal enterotoxin B
    Xue, Pan
    Li, Yongming
    Zhang, Zhujun
    Fu, Aihua
    Liu, Fei
    Zhang, Xiaoming
    Sun, Yuanjie
    Chen, Lili
    Jin, Boquan
    Yang, Kun
    MICROCHIMICA ACTA, 2011, 174 (1-2) : 167 - 174
  • [30] Novel chemiluminescent assay for staphylococcal enterotoxin B
    Pan Xue
    Yongming Li
    Zhujun Zhang
    Aihua Fu
    Fei Liu
    Xiaoming Zhang
    Yuanjie Sun
    Lili Chen
    Boquan Jin
    Kun Yang
    Microchimica Acta, 2011, 174 : 167 - 174