A novel electrochemical immunosensor based on magnetosomes for detection of staphylococcal enterotoxin B in milk

被引:37
|
作者
Wu, Longyun [1 ]
Gao, Bo [1 ]
Zhang, Fang [1 ]
Sun, Xiulan [1 ]
Zhang, Yinzhi [1 ]
Li, Zaijun [1 ,2 ]
机构
[1] Jiangnan Univ, Sch Food Sci, State Key Lab Food Sci & Technol, Wuxi 214122, Jiangsu, Peoples R China
[2] Jiangnan Univ, Sch Chem & Mat Engn, Wuxi 214122, Jiangsu, Peoples R China
关键词
Polyaniline nano-gold composite; Magnetosomes; Electrochemical immunosensor; Staphylococcal enterotoxin B; MAGNETIC BEADS; DAIRY-PRODUCTS; NANOPARTICLES; ANTIBODY; IMMUNOASSAY; ELECTRODE; ANTIGEN; SYSTEM; LIQUID; VIRUS;
D O I
10.1016/j.talanta.2012.12.053
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, a novel electrochemical immunosensor to detect staphylococcal enterotoxin B based on bio-magnetosomes, polyaniline nano-gold composite and 1,2-dimethyl-3-butylimidazolium hexafluorphosphate ionic liquid, was developed, and found to exhibit high sensitivity and stability. The specific antibody to staphylococcal enterotoxin B conjugated with the magnetosomes showed rapid immunoreactions and good dispersion, which contributed to the formation of a nanostructurally smooth and dense film on the surface of a gold electrode. Polyaniline nano-gold composite and 1,2-dimethyl-3-butylimidazolium hexafluorophosphate ionic liquid were used to modify the electrode as mediators to improve the electron transfer and offer an excellent biocompatible microenvironment for the antibody to retain its activity to enhance the response of the electrochemical sensor. Under optimal conditions, the developed immunosensor showed a good linear response in the range from 0.05 to 5 ng/mL (R-2=0.9957) with a detection limit as low as 0.017 ng/mL, compared with the one without magnetosomes (0.05-5 ng/mL, 0.033 ng/mL), this developed immunosensor showed a wider response range and a reduced detection limit. And a good specificity with little adsorption to staphylococcal enterotoxin A, C and Na+, K+, Ca2+ was obtained. Moreover, the immunosensor exhibited a good long-time stability at 4 degrees C reaching up to 60 days, which showed a relatively long working life. Meanwhile the immunosensor could be regenerated four times using NaOH elution. The sensor also displayed a good repeatability with a relative standard deviation of 5.02% for staphylococcal enterotoxin B detection (1 ng/mL, n=9). Furthermore, high recoveries in milk samples from 81% to 118% were achieved and successfully applied to milk sample detection. The obtained results demonstrate that the developed electrochemical immunosensor is a promising tool for the detection of staphylococcal enterotoxin B in food. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:360 / 366
页数:7
相关论文
共 50 条
  • [41] Development of a piezoelectric crystal immunosensor for the detection of C2 type Staphylococcal Enterotoxin
    Gao, ZX
    Chao, FH
    Tao, GQ
    Li, GX
    Zhang, C
    TECHNICAL DIGEST OF THE SEVENTH INTERNATIONAL MEETING ON CHEMICAL SENSORS, 1998, : 262 - 264
  • [42] Protein A insensitive ELISA detection of staphylococcal enterotoxin B
    Guinet, R.M.F., 1600, Oxford University Press (13):
  • [43] Detection of Staphylococcal Enterotoxin A (SEA) using a sensitive nanomaterial-based electrochemical aptasensor
    Nodoushan, Somayeh Mousavi
    Nasirizadeh, Navid
    Sedighian, Hamid
    Kachuei, Reza
    Azimzadeh-Taft, Mostafa
    Fooladi, Abbas Ali Imani
    DIAMOND AND RELATED MATERIALS, 2022, 127
  • [44] DETECTION OF STAPHYLOCOCCAL ENTEROTOXIN-B IN DIFFERENT SUBSTRATES
    HAHN, G
    HEESCHEN, W
    SUDI, J
    KIELER MILCHWIRTSCHAFTLICHE FORSCHUNGSBERICHTE, 1986, 38 (04): : 217 - 225
  • [45] Detection of staphylococcal enterotoxin B in spiked food samples
    Shriver-Lake, LC
    Shubin, YS
    Ligler, FS
    JOURNAL OF FOOD PROTECTION, 2003, 66 (10) : 1851 - 1856
  • [46] DETECTION OF STAPHYLOCOCCAL ENTEROTOXIN-B BY AFFINITY RADIOIMMUNOASSAY
    NIYOMVIT, N
    STEVENSON, KE
    MCFEETERS, RF
    JOURNAL OF FOOD SCIENCE, 1978, 43 (03) : 735 - 739
  • [47] A novel electrochemical immunosensor for the sensitive detection of tiamulin based on staphylococcal protein A and silver nanoparticle-graphene oxide nanocomposites
    You, Xiaojuan
    Zhang, Gaiping
    Chen, Yumei
    Liu, Dan
    Ma, Dongdong
    Zhou, Jingming
    Liu, Yankai
    Liu, Hongliang
    Qi, Yanhua
    Liang, Chao
    Ding, Peiyang
    Zhu, Xifang
    Zhang, Chenyang
    Wang, Aiping
    BIOELECTROCHEMISTRY, 2021, 141
  • [48] A simple and rapid fluorescence-based immunoassay for the detection of staphylococcal enterotoxin B
    Khan, AS
    Cao, CJ
    Thompson, RG
    Valdes, JJ
    MOLECULAR AND CELLULAR PROBES, 2003, 17 (2-3) : 125 - 126
  • [49] Development of sandwich chemiluminescent immunoassay based on an anti-staphylococcal enterotoxin B Nanobody-Alkaline phosphatase fusion protein for detection of staphylococcal enterotoxin B
    Sun, Tieqiang
    Zhao, Zunquan
    Liu, Wentao
    Xu, Zehua
    He, Hongwei
    Ning, Baoan
    Jiang, Yongqiang
    Gao, Zhixian
    ANALYTICA CHIMICA ACTA, 2020, 1108 : 28 - 36
  • [50] IMMUNOFLUORESCENT DETECTION OF STAPHYLOCOCCAL ENTEROTOXIN B .2. DETECTION IN FOODS
    GENIGEORGIS, C
    SADLER, WW
    JOURNAL OF FOOD SCIENCE, 1966, 31 (04) : 605 - +