Detection of a novel glycodelin biomarker using electrochemical immunosensor for endometriosis

被引:23
|
作者
Kalyani, Thangapandi [1 ]
Nanda, Amalesh [1 ]
Jana, Saikat Kumar [1 ]
机构
[1] Natl Inst Technol, Dept Biotechnol, Papum Pare 791112, Arunachal Prade, India
关键词
Endometriosis; Glycodelin; Immunosensor; Cysteamine; Label-free; SQUARE-WAVE; LABEL; ANTIGEN; CA-125; SERUM; ELECTRODES; ANTIBODIES; SENSOR; WOMEN;
D O I
10.1016/j.aca.2020.11.015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Endometriosis is one of the important issues in women worldwide, which decreases the quality of women's lives in their reproductive age. The diagnosis of endometriosis is carried out by the invasive procedure, which is expensive and painful. In the last few decades, researchers have given more attention to constructing a suitable biomarker-based biosensor for semi/non-invasive diagnosis of endometriosis. As a result, glycodelin (GLY) was found as a promising biomarker because of its selectivity and sensitivity. To the best of our knowledge, it was the first study that reported the detection of GLY biomarker using an electrochemical immunosensor. Briefly, a label-free electrochemical immunosensing platform was constructed through in-situ surface modification of cysteamine layer and immobilisation of antibody (anti-GLY) with help of glutaraldehyde. The interaction between antigen and antibody was measured using square wave voltammetry (SWV). The SWV signal could decrease proportionally with the increasing GLY concentration ranging from 1 to 1000 ng mL(-1) (R-2 = 0.9981) and a detection limit (LOD) of 0.43 ng mL(-1). Moreover, an immunosensor could exhibit high sensitivity, selectivity, long-term stability, reproducibility and regeneration. Accuracy of the immunosensor was compared with enzyme-linked immunosorbent assay (ELISA), and satisfying results were obtained. The detection of GLY biomarker may be a new possibility for endometriosis diagnosis. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页码:146 / 154
页数:9
相关论文
共 50 条
  • [21] Electrochemical Detection of Fluoroquinolone Antibiotics in Milk Using a Magneto Immunosensor
    Pinacho, Daniel G.
    Sanchez-Baeza, Francisco
    Pividori, Maria-Isabel
    Marco, Maria-Pilar
    SENSORS, 2014, 14 (09): : 15965 - 15980
  • [22] Construction of novel electrochemical immunosensor for detection of prostate specific antigen using ferrocene-PAMAM dendrimers
    Cevik, Emre
    Bahar, Ozlem
    Senel, Mehmet
    Abasiyanik, M. Fatih
    BIOSENSORS & BIOELECTRONICS, 2016, 86 : 1074 - 1079
  • [23] Fabrication of a novel electrochemical immunosensor for the sensitive detection of carcinoembryonic antigen using a double signal attenuation strategy
    Wang, Xiao
    Liao, Xiaochen
    Zhang, Bingjian
    Chen, Siyu
    Zhang, Mengmeng
    Mei, Lisha
    Zhang, Li
    Qiao, Xiuwen
    Hong, Chenglin
    ANALYTICA CHIMICA ACTA, 2022, 1232
  • [24] A Simple Sandwich Electrochemical Immunosensor for Rapid Detection of the Alzheimer's Disease Biomarker Tau Protein
    Yang, Mingzhu
    Chen, Yihong
    Sun, Hongyu
    Li, Dujuan
    Li, Yanbin
    BIOSENSORS-BASEL, 2024, 14 (06):
  • [25] Carboxylic group riched graphene oxide based disposable electrochemical immunosensor for cancer biomarker detection
    Rauf, Sajid
    Mishra, Geetesh K.
    Azhar, Jahanzaib
    Mishra, Rupesh K.
    Goud, K. Yugender
    Nawaz, Muhammad Azhar Hayat
    Marty, Jean Louis
    Hayat, Akhtar
    ANALYTICAL BIOCHEMISTRY, 2018, 545 : 13 - 19
  • [26] Electrochemical immunosensor with surface-confined probe for sensitive and reagentless detection of breast cancer biomarker
    Zhong, Huage
    Zhao, Chang
    Chen, Jie
    Chen, Miao
    Luo, Tao
    Tang, Weizhong
    Liu, Junjie
    RSC ADVANCES, 2020, 10 (38) : 22291 - 22296
  • [27] Design and fabrication of an electrochemical-based nanofibrous immunosensor for detection of prostate cancer biomarker, PSMA
    Rezaei, Zahra
    Alemzadeh, Iran
    Vossoughi, Manouchehr
    POLYMERS FOR ADVANCED TECHNOLOGIES, 2022, 33 (06) : 1967 - 1977
  • [28] Nanogold-Enriched Carbon Nanohorn Label for Sensitive Electrochemical Detection of Biomarker on a Disposable Immunosensor
    Zhao, Changrong
    Lin, Dajie
    Wu, Jie
    Ding, Lin
    Ju, Huangxian
    Yan, Feng
    ELECTROANALYSIS, 2013, 25 (04) : 1044 - 1049
  • [29] Design of a piezoelectric immunosensor for tuberculosis biomarker detection
    Jaramillo, M.
    Montagut, Y. J.
    Montoya, A.
    Robledo, J.
    Marin, P. A.
    Betancur, J. E.
    Moreno, M. J.
    Pabon, E.
    Torres, R. A.
    2013 PAN AMERICAN HEALTH CARE EXCHANGES (PAHCE), 2013,
  • [30] Electrochemical impedance immunosensor for ferritin detection
    Mengulluogh, U.
    Dinckaya, E.
    NEW BIOTECHNOLOGY, 2018, 44 : S146 - S146